ACTION ITEMS
 +
 +
* Remind Radcon about sending numbers
 +
 +
* CPS radiation simulations: additional tests to finalize CPS optimized geometry (see emails)
 +
 +
* Hall D - prepare a sketch model of magnet
 +
 +
* TCS: for Q2=5 GeV2 want reliable extraction of CFF and show that one can have a good measurement in Hall A/C
 +
 +
 +
SUMMARY NOTES
 +
 +
RADIATION SIMULATION
 +
 +
* discussion of a number of different simulations carried out to optimize cost, material, dimensions - done in two ways: 1) geometry, material, layering, and 2) pure material
 +
 +
* If replace all tungsten with lead, then prompt radiation significantly worse, but activation levels still looks good
 +
 +
* Replacing tungsten by lead in the backward region has reasonable prompt and activation levels depending on how much lead is used - lead below z=0 seems a good compromise
 +
 +
* Having a lead "frame" outside (2.5 cm top, 5cm bottom) helps to reduce radiation levels even further

Revision as of 17:25, 24 February 2020

DISCUSSION MATERIAL

  • Update from CPS beamline meeting
  • Update from KLong and GlueX collaboration meetings


ACTION ITEMS

  • Remind Radcon about sending numbers
  • CPS radiation simulations: additional tests to finalize CPS optimized geometry (see emails)
  • Hall D - prepare a sketch model of magnet
  • TCS: for Q2=5 GeV2 want reliable extraction of CFF and show that one can have a good measurement in Hall A/C


SUMMARY NOTES

RADIATION SIMULATION

  • discussion of a number of different simulations carried out to optimize cost, material, dimensions - done in two ways: 1) geometry, material, layering, and 2) pure material
  • If replace all tungsten with lead, then prompt radiation significantly worse, but activation levels still looks good
  • Replacing tungsten by lead in the backward region has reasonable prompt and activation levels depending on how much lead is used - lead below z=0 seems a good compromise
  • Having a lead "frame" outside (2.5 cm top, 5cm bottom) helps to reduce radiation levels even further