Difference between revisions of "General Meson SF Meeting Agenda 11/18/21"
Jump to navigation
Jump to search
(8 intermediate revisions by the same user not shown) | |||
Line 8: | Line 8: | ||
EIC_mesonMC generator ECCE Results | EIC_mesonMC generator ECCE Results | ||
− | ::* Kinematic plots ([https://wiki.jlab.org/cuawiki/images | + | ::* Kinematic plots ([https://wiki.jlab.org/cuawiki/images/c/ca/Kin_plots_IP6.pdf IP6], [https://wiki.jlab.org/cuawiki/images/0/09/Kin_plots_IP8.pdf IP8]) |
::* Detector plots ([https://wiki.jlab.org/cuawiki/images/6/68/Det_plots_IP6.pdf IP6], [https://wiki.jlab.org/cuawiki/images/8/83/Det_plots_IP8.pdf IP8]) | ::* Detector plots ([https://wiki.jlab.org/cuawiki/images/6/68/Det_plots_IP6.pdf IP6], [https://wiki.jlab.org/cuawiki/images/8/83/Det_plots_IP8.pdf IP8]) | ||
::* Momentum plots ([https://wiki.jlab.org/cuawiki/images/9/9a/Mom_plots_IP6.pdf IP6], [https://wiki.jlab.org/cuawiki/images/a/ac/Mom_plots_IP8.pdf IP8]) | ::* Momentum plots ([https://wiki.jlab.org/cuawiki/images/9/9a/Mom_plots_IP6.pdf IP6], [https://wiki.jlab.org/cuawiki/images/a/ac/Mom_plots_IP8.pdf IP8]) | ||
+ | ::* Patrick's impact studies ([https://wiki.jlab.org/cuawiki/images/1/12/JAM_impact_lesspoints.pdf JAM updated plots]) | ||
{| class="wikitable" style="text-align: center; | {| class="wikitable" style="text-align: center; | ||
|+ Meson SF efficiencies | |+ Meson SF efficiencies | ||
|- | |- | ||
− | ! | + | ! !! scope="row" colspan="2" | IP6 !! scope="row" colspan="2" | IP8 |
|- | |- | ||
− | ! Energy !! | + | ! Energy !! Detection Fraction !! Δt !! Detection Fraction !! Δt |
|- | |- | ||
− | | 5on41 || 59% || 0. | + | | 5on41 || 59% || 0.019 || 78% || 0.018 |
|- | |- | ||
− | | 5on100 || 100% || 0. | + | | 5on100 || 100% || 0.007|| 100% || 0.007 |
|- | |- | ||
− | | 10on100 || 100% || 0. | + | | 10on100 || 100% || 0.007 || 100% || 0.007 |
|- | |- | ||
− | | 18on275 || 100% || 0. | + | | 18on275 || 100% || 0.005 || 100% || 0.008 |
|} | |} | ||
* Other | * Other |
Latest revision as of 22:57, 23 November 2021
DISCUSSION ITEMS
- Global fits - impact studies
- Comparison IP6/IP8
- detection efficiencies
- t-resolution
EIC_mesonMC generator ECCE Results
IP6 | IP8 | |||
---|---|---|---|---|
Energy | Detection Fraction | Δt | Detection Fraction | Δt |
5on41 | 59% | 0.019 | 78% | 0.018 |
5on100 | 100% | 0.007 | 100% | 0.007 |
10on100 | 100% | 0.007 | 100% | 0.007 |
18on275 | 100% | 0.005 | 100% | 0.008 |
- Other