General EEEMCal Meeting Summary 10/20/23
Jump to navigation
Jump to search
PARTICIPANTS: Carlos, Gabriel, Justin, Vardan, Josh, Tanja, Sasha, Miroslav, Crytur-USA, Joerg,
READOUT ELECTRONICS
- ASIC development ongoing - developing boards - expect to test in beam on order one year
- Discussion of agenda for electronics meeting
DESIGN/ENGINEERING
- Project collecting information on calibration and monitoring system
- laser for alignment
- laser or LED for monitoring
- Other calorimeters use LED mounted with SiPM board
- EEEMCAL not yet decided on LED or laser
- require constant term to be small
- expect good stats on electrons (using tracker at large angle) and pi0 - so expect enough stats to monitor with physics data any drifts over the long term
- pi0 can use for absolute calibration/monitoring
- EEEMCAL design based on:
- CMS monitoring, NPS, and also check Hall D
- Nonlinearity tests and calibration
- SiPM 10um nonlinearity expected on order few percent - much worse than for 15um
- Ongoing discussions about EEEMCAL attachment points and services/cabling
- ideas for attach
- Studies of cooling ongoing
- thermal calculations and ongoing
RADIATION TESTS OF SIPM
- Explore options for radiation tests, especially for protons and neutrons