Difference between revisions of "AIEC Deployment"

From epsciwiki
Jump to navigation Jump to search
Line 16: Line 16:
 
|-
 
|-
 
|PrimEx
 
|PrimEx
|2021
+
|Oct-Nov 2021??
 
|[[PrimEx_instructions]]
 
|[[PrimEx_instructions]]
|GPR, trained on GlueX-2020
+
|
 +
*GPR, trained on GlueX-2020
 +
*Default HV 2125V
 
|
 
|
 
*Shifters ran the scripts to read EPICS and suggest HV, before setting HV and starting the run
 
*Shifters ran the scripts to read EPICS and suggest HV, before setting HV and starting the run
 
*HV predictions were rounded to 5V steps
 
*HV predictions were rounded to 5V steps
*Much of the run was with empty target.  Shifters were not supposed to use the AI w empty tgt but they did.
+
*Much of the run was with empty target.  Shifters were not supposed to use the AI w empty tgt but they did.  
 +
*The shifters were not asked to set the HV to 2125V before running the AI. This was not ideal, but saved time. 
 +
|-
 +
|Cosmics
 +
|March 2022
 +
|[[Cosmics_test_plans]]
 +
|
 +
*GPR, trained on GlueX-2020 + PrimEx2021
 +
*Default HV 2130V
 +
*HVB current fixed at 9A
 +
*Temp fixed at start of run
 +
|
 +
*RoboCDC ran autonomously, setting the HV every 5 minutes.
 +
*Half of the CDC was kept at fixed default HV.
 +
*Temp fixed at 299 or 300K until FDC LV brought temp into trained region
 
|-
 
|-
 +
|CPP
 +
|June 2022
 +
|
 +
|
 +
*Linear regression with Bayesian learned prior???, trained on GlueX-2020 + PrimEx2021
 +
*Uncertainty quantification used to determine when to return to the comfort zone (3%?)
 +
*Default HV  2125V
 +
|
 +
*RoboCDC summoned by DAQ prestart to read EPICS and set HV.
 +
*Overall on/off switch added to CDC HV control gui.
 +
*RoboCDC scaled the HVB current reading to what it would have been at the default HV
 +
 +
 
|}
 
|}

Revision as of 15:04, 19 May 2022

Summary of when it was used and what was different each time.

PrimEx 2021 Cosmics 2022 CPP 2022


Presentations/Papers

Experiment Date Wiki Model Other details
PrimEx Oct-Nov 2021?? PrimEx_instructions
  • GPR, trained on GlueX-2020
  • Default HV 2125V
  • Shifters ran the scripts to read EPICS and suggest HV, before setting HV and starting the run
  • HV predictions were rounded to 5V steps
  • Much of the run was with empty target. Shifters were not supposed to use the AI w empty tgt but they did.
  • The shifters were not asked to set the HV to 2125V before running the AI. This was not ideal, but saved time.
Cosmics March 2022 Cosmics_test_plans
  • GPR, trained on GlueX-2020 + PrimEx2021
  • Default HV 2130V
  • HVB current fixed at 9A
  • Temp fixed at start of run
  • RoboCDC ran autonomously, setting the HV every 5 minutes.
  • Half of the CDC was kept at fixed default HV.
  • Temp fixed at 299 or 300K until FDC LV brought temp into trained region
CPP June 2022
  • Linear regression with Bayesian learned prior???, trained on GlueX-2020 + PrimEx2021
  • Uncertainty quantification used to determine when to return to the comfort zone (3%?)
  • Default HV 2125V
  • RoboCDC summoned by DAQ prestart to read EPICS and set HV.
  • Overall on/off switch added to CDC HV control gui.
  • RoboCDC scaled the HVB current reading to what it would have been at the default HV