Difference between revisions of "AIEC Deployment"

From epsciwiki
Jump to navigation Jump to search
Line 49: Line 49:
 
[https://halldweb.jlab.org/wiki/index.php/CPP_DAQ/CPP_AIEC_config CPP AIEC CONFIG]
 
[https://halldweb.jlab.org/wiki/index.php/CPP_DAQ/CPP_AIEC_config CPP AIEC CONFIG]
 
|-  
 
|-  
|}
 
 
{| class="wikitable" style="width: 100%;"
 
|-
 
| style="width: 10%" | Experiment
 
| style="width: 10%" | Date
 
| style="width: 20%" | Wiki & reports
 
| style="width: 30%" | Model
 
| style="width: 30%" | Other details
 
|-
 
|PrimEx
 
|Oct-Nov 2021??
 
|[[PrimEx_instructions]]
 
|
 
*GPR, trained on GlueX-2020
 
*Default HV 2125V
 
*HV predictions were rounded to nearest 5V
 
|
 
*Shifters ran the scripts to read EPICS and suggest HV, before setting HV and starting the run
 
*Much of the run was with empty target.  Shifters were not supposed to use the AI w empty tgt but they did.
 
*The shifters were not asked to set the HV to 2125V before running the AI. This was not ideal, but saved time. 
 
|-
 
|Cosmics
 
|March 2022
 
|[[Cosmics_test_plans]]
 
|
 
*GPR, trained on GlueX-2020 + PrimEx2021
 
*Default HV 2130V
 
*HVB current fixed at 9A
 
*Temp fixed at 299K??? at start of run
 
*HV predictions rounded to nearest 1V
 
|
 
*RoboCDC ran autonomously, setting the HV every 5 minutes.
 
*Half of the CDC was kept at fixed default HV.
 
*Temp fixed at 299 or 300K until FDC LV brought temp into trained region
 
|-
 
|CPP
 
|June 2022
 
|[https://halldweb.jlab.org/wiki/index.php/CPP_DAQ/Monitoring_Test_Spring_2022#AIEC_planning CPP plans]
 
|
 
*GPR with MLP (multilayer perceptron) learned prior, trained on GlueX-2020 + PrimEx2021
 
*Uncertainty quantification used to determine when to return to the comfort zone (3%: is threshold for standard_deviation_of_prediction/ideal_GCF)
 
*Default HV  2125V
 
*HV predictions rounded to nearest 1V
 
*/group/halld/AIEC/utilities/CDC_control_ai/cpp/d_cdc_modelneeds/gpflow_params.pkl
 
|
 
*RoboCDC summoned by DAQ 'GO' to read EPICS and set HV.
 
*RoboCDC scaled the HVB current reading to what it would have been at the default HV, before predicting GCF.
 
*Overall on/off switch added to CDC HV control gui.
 
[https://halldweb.jlab.org/wiki/index.php/CPP_DAQ/CPP_AIEC_config CPP AIEC CONFIG]
 
 
 
 
|}
 
|}

Revision as of 00:58, 7 June 2022

Experiment Date Wiki & reports Model Other details
PrimEx Oct-Nov 2021?? PrimEx_instructions
  • GPR, trained on GlueX-2020
  • Default HV 2125V
  • HV predictions were rounded to nearest 5V
  • Shifters ran the scripts to read EPICS and suggest HV, before setting HV and starting the run
  • Much of the run was with empty target. Shifters were not supposed to use the AI w empty tgt but they did.
  • The shifters were not asked to set the HV to 2125V before running the AI. This was not ideal, but saved time.
Cosmics March 2022 Cosmics_test_plans
  • GPR, trained on GlueX-2020 + PrimEx2021
  • Default HV 2130V
  • HVB current fixed at 9A
  • Temp fixed at 299K??? at start of run
  • HV predictions rounded to nearest 1V
  • RoboCDC ran autonomously, setting the HV every 5 minutes.
  • Half of the CDC was kept at fixed default HV.
  • Temp fixed at 299 or 300K until FDC LV brought temp into trained region
CPP June 2022 CPP plans
  • GPR with MLP (multilayer perceptron) learned prior, trained on GlueX-2020 + PrimEx2021
  • Uncertainty quantification used to determine when to return to the comfort zone (3%: is threshold for standard_deviation_of_prediction/ideal_GCF)
  • Default HV 2125V
  • HV predictions rounded to nearest 1V
  • /group/halld/AIEC/utilities/CDC_control_ai/ cpp/d_cdc_modelneeds/gpflow_params.pkl
  • RoboCDC summoned by DAQ 'GO' to read EPICS and set HV.
  • RoboCDC scaled the HVB current reading to what it would have been at the default HV, before predicting GCF.
  • Overall on/off switch added to CDC HV control gui.

CPP AIEC CONFIG