The pressure sensor was not working reliably for most of January.
 
[https://logbooks.jlab.org/entry/4126964 Jan 24 logbook entry describing pressure sensor issues]
 
[https://logbooks.jlab.org/entry/4126964 Jan 24 logbook entry describing pressure sensor issues]
  
Feb 16 RoboCDC control started.  The pressure sensor was not working reliably for most of January.  
+
Feb 16 120739-120745 RoboCDC control on.  
  
Feb 20 10am - 3pm RoboCDC control switched off for the duration of MCC's BCM recalibration (which was found to be unnecessary)
+
Feb 20 120746-120750 10am - 3pm RoboCDC control switched off for the duration of MCC's BCM recalibration (which was found to be unnecessary)
  
 +
Feb 20 120751-120821 RoboCDC control on.
 
Feb 23 4pm ish Changed the current input to fixed because it was causing so many badepics
 
Feb 23 4pm ish Changed the current input to fixed because it was causing so many badepics
Midnight ish switched the control off because the script was running so late and setting the HV after the run started.
 
  
Feb 25 Control switched back on for one run and then off again afterwards.
+
Feb 24 120822-120830 switched the control off because the script was running so late and setting the HV after the run started.
 +
 
 +
Feb 25 120831-120832 Control switched back on for two runs and then off again afterwards.
  
 
Mar 1 Late evening control switched back on, HV set to 2123V during tests, script failed and HV remained at 2123 overnight.
 
Mar 1 Late evening control switched back on, HV set to 2123V during tests, script failed and HV remained at 2123 overnight.

Revision as of 18:07, 13 October 2023

EPICS overview - change the dates to suit

Same, with temperature

DAQ status in EPICS

HV scan instructions

RC meeting page

Shift leader instructions & desperate logbook entry on prestarts


wish list Remaining items are EPICS gathering (Thomas) & move to Prestart (David in Jan, or ask Sergey)


The default GCF in CCDB for runs 120,000+ is 0.1491. This is good. Summer 2020 runs 72075 and 72766 started at close to 350nA and w pressure close to (and on either side of) 100kPa, have GCFs 0.148 and 0.150.


Run starts Jan 12

Naomi out Jan 3-23.

Initialization?

source $HOSS_VENV/bin/activate.csh
python3 /group/halld/AIEC/AIEC_CDC.py -c /group/halld/AIEC/AIEC_CDC.cfg -I 15

The pressure sensor was not working reliably for most of January. Jan 24 logbook entry describing pressure sensor issues

Feb 16 120739-120745 RoboCDC control on.

Feb 20 120746-120750 10am - 3pm RoboCDC control switched off for the duration of MCC's BCM recalibration (which was found to be unnecessary)

Feb 20 120751-120821 RoboCDC control on. Feb 23 4pm ish Changed the current input to fixed because it was causing so many badepics

Feb 24 120822-120830 switched the control off because the script was running so late and setting the HV after the run started.

Feb 25 120831-120832 Control switched back on for two runs and then off again afterwards.

Mar 1 Late evening control switched back on, HV set to 2123V during tests, script failed and HV remained at 2123 overnight.

Mar 2 10:30 HV set back to 2125V manually. Control still on. Resumed operation correctly later that day (there was a long beam outage).

Mar 6 Control switched off for high current tests. Control switched on after tests were abandoned when maintenance day was declared.

Mar 7 Control switched off during high current tests.

Mar 8 Control switched off during high current tests.