  • Page 4, right column: Stride = (1,2). Is this effectively just convolving 2 values?
  • Fig. 9: They are mainly focused on the left edge where the efficiency is above the 99.5% level (dotted grey line). This is the region of the steepest gradient of purity (i.e. dpurity/dresponse is large)
  • Fig. 10 (described at bottom of page 6) is for tracks from real data. Wouldn't this include the hardware trigger already?
  • Fig. 12: The linear extrapolation of the traditional trigger looks like they are being generous. In reality, the traditional trigger probably does much worse are higher beam currents. If a curve was fit to the actual data points shown though, the extrapolation to 90nA would have a negative purity which is unphysical.
  • Eqn. 4 seems like it should be a ratio rather than a difference. Specifically, wouldn't the data reduction be the ratio of P_AI to P_CLAS12? The data rate for a given trigger would proportional to (TP+FP)