Cosmics test plans

From epsciwiki
Revision as of 14:53, 10 February 2022 by Davidl (talk | contribs)
Jump to navigation Jump to search

Objectives:

  • Test drive the AIEC software
  • Demonstrate that the CDC gain is stable


Strategy:

  • Designate 2130V as the nominal HV for cosmics, to raise more hits above the noise, but keep 20V headroom for the AI.
  • Tell the AI that the HVB current is constant at 9uA so that it can operate within the range of its trained data
  • Use 1V steps and 1h runs
    • Starting new run every hour for 2 weeks may not be feasible. Devise scheme to break up long runs?


Needs:

  • AIEC software to read epics and wait for a stable period before calculating the gain and setting the HV
  • Method for scaling the HVB current to what it would be at the nominal HV before running the AI - will not be needed for cosmics but will be needed for CPP.
  • Script to project dE/dx for 4-10 GeV tracks, fit it and calculate the gain factor
  • Code to set whole quadrants to same value

Questions:

  • Do we need to force a B field in the reconstruction sw (wait for Simon to answer)
    • Simon reported progress on straight track reconstruction (email to David and Naomi Feb. 24th)
  • Full DAQ or standalone DAQ?
    • Ask Sergey for configuration with only CDC, BCAL
  • When are we doing this?
    • March 1-14, 2022