Summary of when it was used and what was different each time.
PrimEx 2021
Cosmics 2022
CPP 2022
Experiment
|
Date
|
Wiki & reports
|
Model
|
Other details
|
PrimEx
|
Oct-Nov 2021??
|
PrimEx_instructions
|
- GPR, trained on GlueX-2020
- Default HV 2125V
|
- Shifters ran the scripts to read EPICS and suggest HV, before setting HV and starting the run
- HV predictions were rounded to 5V steps
- Much of the run was with empty target. Shifters were not supposed to use the AI w empty tgt but they did.
- The shifters were not asked to set the HV to 2125V before running the AI. This was not ideal, but saved time.
|
Cosmics
|
March 2022
|
Cosmics_test_plans
|
- GPR, trained on GlueX-2020 + PrimEx2021
- Default HV 2130V
- HVB current fixed at 9A
- Temp fixed at start of run
|
- RoboCDC ran autonomously, setting the HV every 5 minutes.
- Half of the CDC was kept at fixed default HV.
- Temp fixed at 299 or 300K until FDC LV brought temp into trained region
|
CPP
|
June 2022
|
|
- Linear regression with Bayesian learned prior???, trained on GlueX-2020 + PrimEx2021
- Uncertainty quantification used to determine when to return to the comfort zone (3%?)
- Default HV 2125V
|
- RoboCDC summoned by DAQ prestart to read EPICS and set HV.
- Overall on/off switch added to CDC HV control gui.
- RoboCDC scaled the HVB current reading to what it would have been at the default HV
|