PrimEx instructions
Jump to navigation
Jump to search
Log on to the counting house bluejeans and talk to the shift leader. The shift schedule is linked here .
Start up a VNC session, following these instructions
To run the AI, gathering epics for the previous minute:
- Logon to gluon47 as hdops
- cd /group/halld/Users/njarvis/aiec
- ./runai.sh
If the beam is fluctuating more usual, you might want to run it for the previous 2 minutes instead:
- ./runai.sh 2
Set the HV back to 2125 V when you finish
Before deployment, the AI was initialized, when the CDC's HV and the beam current were at their nominal values. This was done by running ./initai.sh This wrote the D1 max temp in K and the mean AI HVB current into the file defaults.txt which is read in by runai.sh.
Both initai and runai append a summary into log.txt.