Difference between revisions of "HPS DAQ Reboot Procedure"

From hps run
Jump to navigation Jump to search
 
(11 intermediate revisions by the same user not shown)
Line 1: Line 1:
=== 1. From the main HPS_EPICS screen, click ''DAQ Status''' to open the rebooting screen. ===
+
=== 1. From the main HPS_EPICS screen, click ''DAQ Status'' to open the rebooting screen. ===
 
[[Image:hps_epics_top.png|200px]]  
 
[[Image:hps_epics_top.png|200px]]  
  
=== 2. From there click "Full DAQ Reboot" and the popup confirmation. ===
+
=== 2. From there click ''Reboot Full DAQ'' and the popup confirmation. ===
 
[[Image:hps_epics_fulldaqreboot.png|200px]]
 
[[Image:hps_epics_fulldaqreboot.png|200px]]
[[Image:hps_epics_fulldaqreboot_confirm.png|100px]]
+
[[Image:hps_epics_fulldaqreboot_confirm.png|200px]]
  
=== 3. This will open a terminal.  It may ask for clasrun's password, in which case you enter it. ===
+
=== 3. This will open a terminal.  It may ask for <tt>clasrun</tt>'s password, in which case you enter it. ===
 
[[Image:hps_daq_reboot_1.png|400px]]
 
[[Image:hps_daq_reboot_1.png|400px]]
  
=== 4. After rebooting the T-DAQ, press enter to proceed rebooting the SVT-DAQ:===
+
=== 4. After rebooting the T-DAQ, press enter to proceed rebooting the SVT-DAQ (and enter <tt>clasrun</tt>'s password if requested):===
[[Image:hps_epics_svtdaqreboot_confirm.png|200px]]
+
[[Image:hps_epics_svtdaqreboot_confirm.png|400px]]
  
=== 5a. If during the SVT stages, it hangs more than a few seconds, abort with ctrl-C as instructed:===
+
=== 4a. If during the SVT stages, it hangs more than a few seconds, abort with <tt>ctrl-C</tt> as instructed by the messages in the terminal, and then click "Reboot SVT DAQ" button:===
[[Image:hps_epics_svtdaqreboot_hang.png|200px]]
+
[[Image:hps_epics_svtdaqreboot_hang.png|400px]]
 +
[[Image:hps_epics_svtdaqreboot.png|200px]]
  
=== 5b. And then click the SVT DAQ Reboot Button. ===
+
=== 6. Restart runcontrol (it should have been killed automatically during the previous steps) in the appropriate vncviewer.  ===
[[Image:hps_epics_svtdaqreboot.png|200px]]
+
 
 +
====There should be a terminal open where runcontrol was last restarted, in which case you can press up to get it from the shell history and run it..====
 +
==== Otherwise, login as user=<tt>clasrun</tt> to <tt>clondaq3</tt> and execute:====
  
 +
===<tt>runcontrol -rocs -log</tt> ===
  
  
 
__NOTOC__
 
__NOTOC__
 
__NOEDITSECTION__
 
__NOEDITSECTION__

Latest revision as of 10:52, 23 April 2016

1. From the main HPS_EPICS screen, click DAQ Status to open the rebooting screen.

Hps epics top.png

2. From there click Reboot Full DAQ and the popup confirmation.

Hps epics fulldaqreboot.png Hps epics fulldaqreboot confirm.png

3. This will open a terminal. It may ask for clasrun's password, in which case you enter it.

Hps daq reboot 1.png

4. After rebooting the T-DAQ, press enter to proceed rebooting the SVT-DAQ (and enter clasrun's password if requested):

Hps epics svtdaqreboot confirm.png

4a. If during the SVT stages, it hangs more than a few seconds, abort with ctrl-C as instructed by the messages in the terminal, and then click "Reboot SVT DAQ" button:

Hps epics svtdaqreboot hang.png Hps epics svtdaqreboot.png

6. Restart runcontrol (it should have been killed automatically during the previous steps) in the appropriate vncviewer.

There should be a terminal open where runcontrol was last restarted, in which case you can press up to get it from the shell history and run it..

Otherwise, login as user=clasrun to clondaq3 and execute:

runcontrol -rocs -log