* Status of thermal analysis (Hovanes,Tim) | * Status of thermal analysis (Hovanes,Tim) | ||
*: [[media:klcps77_temps_10_16_2023.pdf | Results for KLCPS77 from Mathematica]] | *: [[media:klcps77_temps_10_16_2023.pdf | Results for KLCPS77 from Mathematica]] | ||
− | * CPS model updates (Pavel) | + | * [[media:cps_update_16Oct2023.pptx | CPS model updates ]] (Pavel) |
* Tagger/CPS magnet power supply | * Tagger/CPS magnet power supply | ||
:* [https://logbooks.jlab.org/entry/4156536 CPS magnet prototype model coil parameters]: | :* [https://logbooks.jlab.org/entry/4156536 CPS magnet prototype model coil parameters]: | ||
:*: S = 8cm x 7cm, j_avg = 67 Amps/cm^2. Assuming 16 turns ⟶ I_ps = 234.5 Amps, L_16turns ≈ 27 m, and R_16turns ≈ 1.36 mΩ . | :*: S = 8cm x 7cm, j_avg = 67 Amps/cm^2. Assuming 16 turns ⟶ I_ps = 234.5 Amps, L_16turns ≈ 27 m, and R_16turns ≈ 1.36 mΩ . | ||
+ | * Radiation hardness of equipment in the hall (Vitaly). | ||
* Any other business | * Any other business |
Revision as of 09:37, 17 October 2023
- Announcements
- Status of thermal analysis (Hovanes,Tim)
- CPS model updates (Pavel)
- Tagger/CPS magnet power supply
- CPS magnet prototype model coil parameters:
- S = 8cm x 7cm, j_avg = 67 Amps/cm^2. Assuming 16 turns ⟶ I_ps = 234.5 Amps, L_16turns ≈ 27 m, and R_16turns ≈ 1.36 mΩ .
- CPS magnet prototype model coil parameters:
- Radiation hardness of equipment in the hall (Vitaly).