Difference between revisions of "Absolute Beam Energy"

From Ciswikidb
Jump to navigation Jump to search
Line 26: Line 26:
  
 
==PEPPo Results==
 
==PEPPo Results==
 +
 +
'''Momentum Measurement:'''
  
 
* Joe's summary of beam momentum: [[Media:130724_Bubble_Grames.pdf]]
 
* Joe's summary of beam momentum: [[Media:130724_Bubble_Grames.pdf]]
Line 31: Line 33:
 
* Joe's followup: [[Media:130718_FollowUp_Momentum_Grames.pdf]]
 
* Joe's followup: [[Media:130718_FollowUp_Momentum_Grames.pdf]]
 
* Joe's followup: BPM quad centering [[Media:130726_MomentumFollowUp2_Grames.pdf]]
 
* Joe's followup: BPM quad centering [[Media:130726_MomentumFollowUp2_Grames.pdf]]
 +
 +
'''Cryounit Gradient:'''
  
 
* ''Upper limit of the electron beam energy at the CEBAF 2D injector spectrometer and its functionality''
 
* ''Upper limit of the electron beam energy at the CEBAF 2D injector spectrometer and its functionality''
 
Jonathan Dumas, Joe Grames, and Eric Voutier [[Media:JLAB-TN-08-086.pdf]]
 
Jonathan Dumas, Joe Grames, and Eric Voutier [[Media:JLAB-TN-08-086.pdf]]

Revision as of 13:35, 6 December 2013

Summary of Beam Properties in JLab Injector

Beam Kinetic Energy, T (MeV) 3.0 – 8.5
Beam Current (µA) 0.01 – 100
Absolute Beam Energy 0.67%
Relative Beam Energy 0.05%
Energy Resolution (Spread), σT /T 0.06%
Beam Size, σx,y (mm) 1 – 2
The goal is to reduce the uncertainty on the absolute beam energy to 0.1% and achieve a relative beam energy of 0.05%.

PEPPo Results

Momentum Measurement:
Cryounit Gradient:
  • Upper limit of the electron beam energy at the CEBAF 2D injector spectrometer and its functionality

Jonathan Dumas, Joe Grames, and Eric Voutier Media:JLAB-TN-08-086.pdf