Difference between revisions of "Absolute Beam Energy"

From Ciswikidb
Jump to navigation Jump to search
Line 14: Line 14:
 
|-  
 
|-  
 
| '''Relative Beam Energy'''
 
| '''Relative Beam Energy'''
|  '''<0.05%'''  
+
|  '''0.1%'''  
 
|-
 
|-
 
| '''Energy Resolution (Spread), σ<sub>T</sub> /T'''
 
| '''Energy Resolution (Spread), σ<sub>T</sub> /T'''
Line 23: Line 23:
 
|}
 
|}
  
  The goal is to reduce the uncertainty on the absolute beam energy to '''0.1%''' and achieve a relative beam energy of '''0.05%'''.
+
  The goal is to reduce the uncertainty on the absolute beam energy to '''0.1%''' and achieve a relative beam energy of '''<0.05%'''.
  
 
==PEPPo Results==
 
==PEPPo Results==

Revision as of 13:39, 6 December 2013

Summary of Beam Properties in JLab Injector

Beam Kinetic Energy, T (MeV) 3.0 – 8.5
Beam Current (µA) 0.01 – 100
Absolute Beam Energy 0.36%
Relative Beam Energy 0.1%
Energy Resolution (Spread), σT /T 0.06%
Beam Size, σx,y (mm) 1 – 2
The goal is to reduce the uncertainty on the absolute beam energy to 0.1% and achieve a relative beam energy of <0.05%.

PEPPo Results

Momentum Measurement:

Cryounit Gradient:

  • Upper limit of the electron beam energy at the CEBAF 2D injector spectrometer and its functionality

Jonathan Dumas, Joe Grames, and Eric Voutier Media:JLAB-TN-08-086.pdf