Difference between revisions of "Spring 2021 - Rebuilding Photogun"
Jump to navigation
Jump to search
Line 13: | Line 13: | ||
===Replace depo schneedle === | ===Replace depo schneedle === | ||
* Make (2) SS schneedle w/o silver plating, replace depo chamber silver plated schneedle [[media:ACC2003000-0219 schneedle.pdf]] | * Make (2) SS schneedle w/o silver plating, replace depo chamber silver plated schneedle [[media:ACC2003000-0219 schneedle.pdf]] | ||
+ | * Galling reduced by addition of Mn and Si | ||
+ | * Nitronic 60 data sheet => https://www.hpalloy.com/Alloys/descriptions/NITRONIC60.aspx?kw=%2Bnitronic%20%2B60&cpn=48402520&utm_term=%2Bnitronic%20%2B60&utm_campaign=NITRONIC&utm_source=adwords&utm_medium=ppc&hsa_net=adwords&hsa_tgt=kwd-41394160017&hsa_ad=393453120372&hsa_acc=6124394374&hsa_grp=1610180530&hsa_mt=b&hsa_cam=48402520&hsa_kw=%2Bnitronic%20%2B60&hsa_ver=3&hsa_src=g&gclid=EAIaIQobChMIzJv0vOnp7wIVypyzCh0bPAmCEAAYASAAEgLYn_D_BwE | ||
+ | * Mir50 => https://www.associatedsteel.com/stainless-steels/17-4-stainless-steel-pump-shaft-stainless-custom-450-stainless-tgp-mir50/ | ||
* NF3 leak value => leave as-is | * NF3 leak value => leave as-is | ||
* align mask, fix w/ two set screws | * align mask, fix w/ two set screws |
Revision as of 09:31, 6 April 2021
Replace cathode electrode
- "old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
- "new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
- leak test large grain Nb cathode/ceramic/flange assembly : << carlos' logbook entry goes here >>
- fiducialize Nb cathode to 10" flange (old method glued fiducials)
- (maybe) fiducialize existing 10" flange to HV chamber
- vent HV chamber, remove cathode electrode, searching for puck tab
- fiducialize anode to HV chamber
- align cathode to anode
- align LM to cathode (after venting depo)
- align HV to chamber Y and re-align laser for retro-reflection
Replace depo schneedle
- Make (2) SS schneedle w/o silver plating, replace depo chamber silver plated schneedle media:ACC2003000-0219 schneedle.pdf
- Galling reduced by addition of Mn and Si
- Nitronic 60 data sheet => https://www.hpalloy.com/Alloys/descriptions/NITRONIC60.aspx?kw=%2Bnitronic%20%2B60&cpn=48402520&utm_term=%2Bnitronic%20%2B60&utm_campaign=NITRONIC&utm_source=adwords&utm_medium=ppc&hsa_net=adwords&hsa_tgt=kwd-41394160017&hsa_ad=393453120372&hsa_acc=6124394374&hsa_grp=1610180530&hsa_mt=b&hsa_cam=48402520&hsa_kw=%2Bnitronic%20%2B60&hsa_ver=3&hsa_src=g&gclid=EAIaIQobChMIzJv0vOnp7wIVypyzCh0bPAmCEAAYASAAEgLYn_D_BwE
- Mir50 => https://www.associatedsteel.com/stainless-steels/17-4-stainless-steel-pump-shaft-stainless-custom-450-stainless-tgp-mir50/
- NF3 leak value => leave as-is
- align mask, fix w/ two set screws
- replace K source with Alvatec Sb source?
Fix pucks
- Inspect and mic pucks against series 30 series dwg media:JL0047248 PUCK BODY REV A.pdf media:MoPuckMount.docx
Other jobs
- Re-align HV chamber before venting? => sent request to Gould
- (done) Repair stalk heater driver => https://logbooks.jlab.org/entry/3871902