Difference between revisions of "Spring 2021 - Rebuilding Photogun"

From Ciswikidb
Jump to navigation Jump to search
Line 1: Line 1:
 
===Replace cathode electrode ===
 
===Replace cathode electrode ===
* "old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
+
* Electrodes
* "new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
+
::"old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
 +
::"new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
 
* leak test large grain Nb cathode/ceramic/flange assembly : << carlos' logbook entry goes here >>
 
* leak test large grain Nb cathode/ceramic/flange assembly : << carlos' logbook entry goes here >>
* fiducialize Nb cathode to 10" flange (old method glued fiducials)
+
* S&A jobs (will walk with Chris Gould 4/7 @ 9am UITF)
* (maybe) fiducialize existing 10" flange to HV chamber
+
:: fiducialize Nb cathode to 10" flange (old method glued fiducials)
 +
:: (maybe) fiducialize existing 10" flange to HV chamber
 +
:: fiducialize anode to HV chamber
 +
:: align cathode to anode
 +
:: align LM to cathode (after venting depo)
 +
:: align HV to chamber Y
 +
* re-align laser for retro-reflection
 
* vent HV chamber, remove cathode electrode, searching for puck tab
 
* vent HV chamber, remove cathode electrode, searching for puck tab
* fiducialize anode to HV chamber
 
* align cathode to anode
 
* align LM to cathode (after venting depo)
 
* align HV to chamber Y and re-align laser for retro-reflection
 
  
 
===Replace depo schneedle ===
 
===Replace depo schneedle ===

Revision as of 09:37, 6 April 2021

Replace cathode electrode

  • Electrodes
"old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
"new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
  • leak test large grain Nb cathode/ceramic/flange assembly : << carlos' logbook entry goes here >>
  • S&A jobs (will walk with Chris Gould 4/7 @ 9am UITF)
fiducialize Nb cathode to 10" flange (old method glued fiducials)
(maybe) fiducialize existing 10" flange to HV chamber
fiducialize anode to HV chamber
align cathode to anode
align LM to cathode (after venting depo)
align HV to chamber Y
  • re-align laser for retro-reflection
  • vent HV chamber, remove cathode electrode, searching for puck tab

Replace depo schneedle

  • NF3 leak value => leave as-is
  • align mask, fix w/ two set screws
  • replace K source with Alvatec Sb source?

Fix pucks

Other jobs