Difference between revisions of "Kerr - August 5, 2016"
(Created page with "thumb|upright=2.5|Use this to interpret Excel descriptions.") |
|||
(12 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[[file:Puckgeometry.jpeg|thumb|upright=2.5|Use this to interpret Excel descriptions.]] | [[file:Puckgeometry.jpeg|thumb|upright=2.5|Use this to interpret Excel descriptions.]] | ||
+ | |||
+ | '''1.''' | ||
+ | '''NEAR Trials with Steel only''' | ||
+ | |||
+ | The following 'a.' and 'b.' describes measurements done with; | ||
+ | * STEEL puck only, {with the exception of a mirror null} | ||
+ | * Angle between laser and photodiode 38.6 -+2.4 degrees | ||
+ | * The Setup was "NEAR" The solenoid | ||
+ | * Center of Optics Stage {between Laser and Photodiode} 58 -+ 1 cm from puck | ||
+ | |||
+ | a. -->->->[[media:NearSetup.xlsx]] | ||
+ | |||
+ | Then Puck stability was investigated | ||
+ | |||
+ | b. -->->-> [[media:Puckchanges.xlsx]] | ||
+ | |||
+ | |||
+ | '''2.''' | ||
+ | '''FAR trials with STEEL and Moly''' | ||
+ | |||
+ | The following file describes measurements done with; | ||
+ | * STEEL and MOLY and a Mirror | ||
+ | * Angle between laser and photodiode 5.31 -+0.45 degrees | ||
+ | * The Setup was "FAR" from The solenoid | ||
+ | * Photodiode 140 cm -+ 2 cm from puck | ||
+ | |||
+ | -->->-> [[media:Farsetup.xlsx]] | ||
+ | |||
+ | '''''IMPORTANT'' NOTE: when observing data sheets, Vdc (ave) (typically column C) is in Volts... Whereas V1f and V2f, (Columns G and K) are in miliVolts.''' | ||
+ | |||
+ | |||
+ | To Convert Current to Magnetic Field use MMF data --->>>[[media:Currenttomagneticfieldmeasurements.xlsx]] | ||
+ | |||
+ | If beam is off center, use the x-trans data to create a new linear relation with same slope, but different y intercept. | ||
+ | |||
+ | |||
+ | |||
+ | '''3.''' | ||
+ | '''''Final Report and Poster''''' | ||
+ | |||
+ | Report --> [[Media:HardyFinalReport.docx]] | ||
+ | |||
+ | Poster --> [[media:HardyFinalPoster.pptx]] |
Latest revision as of 10:33, 9 August 2016
1. NEAR Trials with Steel only
The following 'a.' and 'b.' describes measurements done with;
- STEEL puck only, {with the exception of a mirror null}
- Angle between laser and photodiode 38.6 -+2.4 degrees
- The Setup was "NEAR" The solenoid
- Center of Optics Stage {between Laser and Photodiode} 58 -+ 1 cm from puck
a. -->->->media:NearSetup.xlsx
Then Puck stability was investigated
b. -->->-> media:Puckchanges.xlsx
2.
FAR trials with STEEL and Moly
The following file describes measurements done with;
- STEEL and MOLY and a Mirror
- Angle between laser and photodiode 5.31 -+0.45 degrees
- The Setup was "FAR" from The solenoid
- Photodiode 140 cm -+ 2 cm from puck
-->->-> media:Farsetup.xlsx
IMPORTANT NOTE: when observing data sheets, Vdc (ave) (typically column C) is in Volts... Whereas V1f and V2f, (Columns G and K) are in miliVolts.
To Convert Current to Magnetic Field use MMF data --->>>media:Currenttomagneticfieldmeasurements.xlsx
If beam is off center, use the x-trans data to create a new linear relation with same slope, but different y intercept.
3. Final Report and Poster
Report --> Media:HardyFinalReport.docx
Poster --> media:HardyFinalPoster.pptx