Replace cathode electrode
- "old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
- "new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
- leak test large grain Nb cathode/ceramic/flange assembly : << carlos' logbook entry goes here >>
- fiducialize Nb cathode to 10" flange (old method glued fiducials)
- (maybe) fiducialize existing 10" flange to HV chamber
- vent HV chamber, remove cathode electrode, searching for puck tab
- fiducialize anode to HV chamber
- align cathode to anode
- align LM to cathode (after venting depo)
- align HV to chamber Y and re-align laser for retro-reflection
Replace depo schneedle
- Make (2) SS schneedle w/o silver plating, replace depo chamber silver plated schneedle media:ACC2003000-0219 schneedle.pdf
- Galling reduced by addition of Mn and Si
- Nitronic 60 data sheet (Nitronic trademark AK Steel)
- Mir50 (Mir50 trademark ASC Steel)
- NF3 leak value => leave as-is
- align mask, fix w/ two set screws
- replace K source with Alvatec Sb source?
Fix pucks
- Inspect and mic pucks against series 30 series dwg media:JL0047248 PUCK BODY REV A.pdf media:MoPuckMount.docx
Other jobs
- Re-align HV chamber before venting? => sent request to Gould
- (done) Repair stalk heater driver => https://logbooks.jlab.org/entry/3871902