200 kV gun

From Ciswikidb
Revision as of 07:02, 28 August 2020 by Grames (talk | contribs) (Created page with " ; High voltage test => evaluate onset of field emission in small HV chamber with tee electrode : Install high voltage insulator or PIG : Plan media:200817_Tee_Evaluation.pp...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
High voltage test => evaluate onset of field emission in small HV chamber with tee electrode
Install high voltage insulator or PIG
Plan media:200817_Tee_Evaluation.pptx
Gun work => replace cathode in small HV chamber with small shed and tee electrode
Install and align new small shed (cut from large shed) SS tee w/ conductive insulator
Replace 10" anode flange (no change to anode spider - tube - anode) with tapped flange for BPM
Remove inline getters
Build new 2I beam line (BPM-tube-BPM-tube/FX-bellows-BPM-valve)
Bake
High voltage test => evaluate on set of field emission, high voltage gas condition to 200 kV no FE