Spring 2021 - Rebuilding Photogun

From Ciswikidb
Revision as of 09:37, 6 April 2021 by Grames (talk | contribs)
Jump to navigation Jump to search

Replace cathode electrode

  • Electrodes
"old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
"new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
  • leak test large grain Nb cathode/ceramic/flange assembly : << carlos' logbook entry goes here >>
  • S&A jobs (will walk with Chris Gould 4/7 @ 9am UITF)
fiducialize Nb cathode to 10" flange (old method glued fiducials)
(maybe) fiducialize existing 10" flange to HV chamber
fiducialize anode to HV chamber
align cathode to anode
align LM to cathode (after venting depo)
align HV to chamber Y
  • re-align laser for retro-reflection
  • vent HV chamber, remove cathode electrode, searching for puck tab

Replace depo schneedle

  • NF3 leak value => leave as-is
  • align mask, fix w/ two set screws
  • replace K source with Alvatec Sb source?

Fix pucks

Other jobs