Difference between revisions of "KPP Run"
Jump to navigation
Jump to search
(79 intermediate revisions by 4 users not shown) | |||
Line 9: | Line 9: | ||
===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]=== | ===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]=== | ||
===[https://bta Beam Time Accounting]=== | ===[https://bta Beam Time Accounting]=== | ||
+ | ===[https://www.jlab.org/Hall-B/run-web/comm/ESAD_HallB-CLAS12_rgA.pdf ESAD], [https://www.jlab.org/Hall-B/run-web/comm/COO_HallB-CLAS12_rgA.pdf COO], [https://www.jlab.org/Hall-B/run-web/comm/RSAD_HallB-CLAS12_rgA.pdf RSAD], [https://www.jlab.org/div_dept/train/SAF111/Hall%20B%20worker%20Safety%20Training%20%28SAF111%29%20%2008%2001-12-1.pdf ERG] === | ||
+ | |||
+ | <br><br> | ||
+ | ===[https://wiki.jlab.org/clas12-run/images/e/e2/Offline_-shift-schedule.pdf Off-line shift schedule]=== | ||
+ | |||
+ | <br><br> | ||
+ | ===[https://wiki.jlab.org/clas12-run/images/8/80/HallB_KPP_Demo_data-3.pdf CLAS12 KPP Demonstration Slides]=== | ||
| valign=top | | | valign=top | | ||
===Manuals=== | ===Manuals=== | ||
− | * [https:// | + | * [https://wiki.jlab.org/clas12-run/images/b/b2/Drift-chamber-operating-procedure.pdf DC] |
* [https://www.jlab.org/Hall-B/ftof/notes/ftof_manual.pdf FTOF] | * [https://www.jlab.org/Hall-B/ftof/notes/ftof_manual.pdf FTOF] | ||
* [https://clasweb.jlab.org/wiki/images/a/a2/Ec_manual.pdf ECAL] | * [https://clasweb.jlab.org/wiki/images/a/a2/Ec_manual.pdf ECAL] | ||
− | * [https:// | + | * [https://wiki.jlab.org/clas12-run/images/d/d2/Ltcc_manual.pdf LTCC] |
* [https://clasweb.jlab.org/wiki/images/f/f1/HTCC_MANUAL.pdf HTCC] | * [https://clasweb.jlab.org/wiki/images/f/f1/HTCC_MANUAL.pdf HTCC] | ||
* [https://www.jlab.org/Hall-B/ctof/notes/ctof_manual.pdf CTOF] | * [https://www.jlab.org/Hall-B/ctof/notes/ctof_manual.pdf CTOF] | ||
Line 33: | Line 40: | ||
* [[Media:HarpScanManual.pdf|Performing Harp Scans]] | * [[Media:HarpScanManual.pdf|Performing Harp Scans]] | ||
* [https://wiki.jlab.org/hps-run/images/0/0c/Accessing_the_tunnel.pdf Tunnel/Hall Access] | * [https://wiki.jlab.org/hps-run/images/0/0c/Accessing_the_tunnel.pdf Tunnel/Hall Access] | ||
+ | <br> | ||
+ | * [https://clonwiki0.jlab.org/wiki/index.php/DAQ/Online_Quick_Reference <span style="color:red;"><b>DAQ Quick Reference/Recovery</b></span>] | ||
| valign=top | | | valign=top | | ||
+ | |||
===JLab Logbooks=== | ===JLab Logbooks=== | ||
<font size=3> | <font size=3> | ||
Line 51: | Line 61: | ||
[https://wiki.jlab.org/clas12-run/index.php?title=Template:PhoneNumbers&action=edit Click Here] to edit Phone Numbers. Note, you then also have to [https://wiki.jlab.org/clas12-run/index.php?title=KPP_Run&action=edit§ion=9 edit this page] to force a refresh. | [https://wiki.jlab.org/clas12-run/index.php?title=Template:PhoneNumbers&action=edit Click Here] to edit Phone Numbers. Note, you then also have to [https://wiki.jlab.org/clas12-run/index.php?title=KPP_Run&action=edit§ion=9 edit this page] to force a refresh. | ||
− | <!-- JUST MODIFY AND SAVE ANYTHING IN THIS COMMENT BLOCK TO FORCE A REFRESH OF THE PHONE NUMBERS | + | <!-- JUST MODIFY AND SAVE ANYTHING IN THIS COMMENT BLOCK TO FORCE A REFRESH OF THE PHONE NUMBERS TEMPLATEs--> |
= Short Term Schedule = | = Short Term Schedule = | ||
Line 59: | Line 69: | ||
''' Beam energy 6.4 GeV (3 pass) '''<br> | ''' Beam energy 6.4 GeV (3 pass) '''<br> | ||
''' Important: Document all your work in the logbook! '''<br> | ''' Important: Document all your work in the logbook! '''<br> | ||
+ | == <font color=red>''' Very Successfull Run '''</font>== | ||
<!--<font size=3>[https://bluejeans.com/573852742 Bluejeans for Run Meetings on Thursdays and Fridays at 2pm]</font></center>--> | <!--<font size=3>[https://bluejeans.com/573852742 Bluejeans for Run Meetings on Thursdays and Fridays at 2pm]</font></center>--> | ||
</center> | </center> | ||
Line 73: | Line 84: | ||
| valign=top width=50% | | | valign=top width=50% | | ||
+ | == <font color=blue>''' Run Plan for February 4-5, 2017 : '''</font>== | ||
+ | |||
+ | *Target position <b> 10.505 </b> (2H01 harp, can be moved using button on the main scaler GUI or using the expert GUI) | ||
+ | *Beam current <b> 5 nA </b> (use Faraday Cup) | ||
+ | *Beam positons on 2H01 nA BPM <b> x=0.38, y=0.905 </b> | ||
+ | *CODA configuration - <b> SECTOR2_SVT (sector2 trigger with SVT) <del>SECTOR2 (sector2 only trigger), FC_DC (6-sectors)</del></b> | ||
+ | *Triger file - <b> trigger/kpp1.trg </b> | ||
+ | *Take data, 2 hours a run | ||
+ | *Keep track of runs, run#, torus seting, target position, # of triggers, start/end time, trigger rate | ||
− | == < | + | === Plan: === |
+ | # <del>Complete data taking with Sector-2 only, EC-inner high threshold (5000 fADC units)</del> | ||
+ | #<del> Reverse torus polarity, <b> Set point = -1900 A </b>. First ramp down torus to zero, by setting 0 in the set point, then ramp up to -1900 A.</del> | ||
+ | # <del>Take data with reverse field, Sector-2 only, high EC-inner threshold</del> | ||
+ | # <del>Study tracking efficiency: four HV setings: 8, 9, 10, 11, 12, for each HV four threshold settings: 30, 45, 60, 75. 10 min runs each.</del> | ||
+ | # <del>Continue with data taking torus at -1900 A, target at 13.125, DC HV setting #11, thresholds 45 mV </del> | ||
+ | # <del> Switch target (call RC) and continue data taking till Sunday morning </del> | ||
+ | # <del>Change torus polarity. While torus current is changing, perform harp scans and FSD studies (see below)</del> | ||
+ | # <del>(Sunday morning while torus setting gets changed) Perform beam studies (call RC and beamline, <b> Turn off DC HV </b>):</del> done | ||
+ | #*<del>Do harp scans - 2C21, "tagger", and 2H01 </del> | ||
+ | #*<del>Test FSD system, run Struck scaler with 300um dwel time, ask MCC to set FSD trip time integration times for FSD channels (1 old and 3 new) to 1 ms. Un-mask one FSD channel, run collimator with slmall steps to left or right untill it will intercept beam tails. It will raise rates on halo counters. </del> | ||
+ | # <del>Take one 30 min run with torus at zero </del> done | ||
+ | # Set torus +1900 A, continue data taking, trigger Sector-2 only, high threshold in EC-in (5000 fADC counts) | ||
+ | #* <del>take one run for 3 hours at low luminosity. Move beam in vertical direction up (or down does not matter) with 0.1 mm steps untill rates on downstream counters will be ~5kHz</del>done. x10 lower rates on downstream halo couters (luminosity monitor) | ||
+ | # <del> Take short ~1 hour, random trigger data (Sergei should be in to set it up). Should happen before goimg to 6-sector trigger ~9 pm </del> | ||
+ | # Switch to 6-sector trigger (some time ~11pm), take data till Monday morning. | ||
+ | # <b> Run ends 6:45 am on Monday. Following has to be done: | ||
+ | #* End the run, turn OFF HVs for all detectors, Start Ramping torus down to zero | ||
+ | #* Retract the target using 2H01 expert GUI, just put -10 in the left "MoveAbs" and hit the return. Motor will go towards 0, and will hit "Lo Limit" limit switch | ||
+ | #* Ask MCC to change beam current to 50nA with small steps, this is to calibrate SLM (data goes to MYA, but you can record beam current and the SLM reading if you want) | ||
+ | #* When finished, got to 50nA, ask MCC to terminate the beam and take the Hall to restricted access. | ||
+ | #* When torus reaches to 0 turn the PS OFF.</b> | ||
+ | <!-- | ||
+ | == The Hall was closed and brought to controlled access at 8pm on Thursday, February 2 == | ||
− | + | <b> While no beam, cosmic calibration run is in progress with all CLAS12 detectors ON. | |
− | + | ||
− | + | When ready to get beam, Turn all beamline devices ON, turn all CLAS12 detectors OFF (including SVT)</b> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
== Establish beam to the tagger yoke dump == | == Establish beam to the tagger yoke dump == | ||
− | # Work with MCC to establish beam on the tagger yoke dump | + | # Work with MCC to establish beam on the tagger yoke dump - <b>This is the first time we are running to this new dump, record everything, rates in some of halo counters can be away off the chart. Consult with RC if you see something very unusual. </b> |
− | # See [[Media:CLAS12_beamline_commissioning.pdf|Beamline Commissioning Plans]] for details, execute 2(a) to 2(g). | + | # See [[Media:CLAS12_beamline_commissioning.pdf|Beamline Commissioning Plans]] for details, execute 2(a) to 2(g). <b> Note, MCC may use up to 4 uA tune mode beam for short time periods for steering purposes </b>. |
# Log every harp scan | # Log every harp scan | ||
# Log Main scaler GUI every time conditions change | # Log Main scaler GUI every time conditions change | ||
− | # Follow beam position and current strip charts for 2C21 and 2C24 nA BPMs, make log entry of strip chartes | + | # Follow the beam position and current strip charts for 2C21 and 2C24 nA BPMs, make log entry of strip chartes |
== Bring beam to FC: == | == Bring beam to FC: == | ||
# Establish beam to the Faraday cup following the Beamline Commissioning Plans, execute 2(g) to 2(k). Note, at some point part of CLAS12 calorimeters must be turned on | # Establish beam to the Faraday cup following the Beamline Commissioning Plans, execute 2(g) to 2(k). Note, at some point part of CLAS12 calorimeters must be turned on | ||
# Log every harp scan | # Log every harp scan | ||
# Log Main scaler GUI every time conditions change | # Log Main scaler GUI every time conditions change | ||
− | # Follow beam position and current strip charts for 2C21 and 2C24 nA BPMs, make log entry of strip | + | # Follow the beam position and current strip charts for 2C21 and 2C24 nA BPMs, make log entry of strip charts |
− | + | # Setup FSD if it is day time and beamline expert is present, 2(l) and 2(m), otherwise skip them | |
+ | # Start bringing the CLAS12 detectors ON and do rate studies , 2(n) and 2(o). When moving target in, consult [[Media:Harp_TargetStick.pdf| 2H01 harp stick drawing]] and 2H01 harp scans performed on step 2(k) to define how far you should move the motor to get carbon target on the beam, first bullet of 2(o). | ||
+ | <b> At this point call DAQ, EC, DC, and FTOF experts, notify them that beam is ready for data taking</b> | ||
+ | --> | ||
=== Important Notes: === | === Important Notes: === | ||
+ | # '''During beam tune and harp scans Hall-B halo FSD must be masked.''' | ||
# '''Do not run more than 60 minutes above 30 nA without the beam blocker in front of Faraday cup. Put beam blocker in for long running at high currents.''' | # '''Do not run more than 60 minutes above 30 nA without the beam blocker in front of Faraday cup. Put beam blocker in for long running at high currents.''' | ||
+ | # '''If DAQ crashed/broken: Follow instruction on Documentation tab. If cannot resolved in 20-30 min call DAQ on-call cell phone.''' | ||
+ | # '''With any issue contact On-Call Experts or RC - do not spend more than 15-20 min trying to fix the problem.''' | ||
+ | |||
| valign=top | | | valign=top | | ||
Line 110: | Line 151: | ||
==<font color=blue><b>General Instructions:</b></font>== | ==<font color=blue><b>General Instructions:</b></font>== | ||
− | + | ||
− | + | <!-- | |
# For every daq crash login into clondaq3 as a clasrun then run the following command | # For every daq crash login into clondaq3 as a clasrun then run the following command | ||
#* clasrun@clondaq3:clasrun> <font color='blue'> save_DAQ_logs.pl</font> (See [https://logbooks.jlab.org/files/2016/04/3397123/DAQ_DPM_Crash_0.png]) | #* clasrun@clondaq3:clasrun> <font color='blue'> save_DAQ_logs.pl</font> (See [https://logbooks.jlab.org/files/2016/04/3397123/DAQ_DPM_Crash_0.png]) | ||
− | # [ | + | # [https://clonwiki0.jlab.org/wiki/index.php/DAQ/Online_Quick_Reference Reboot DAQ completely]. |
# If the procedure fails to restore DAQ, call Sergey (DAQ on call) without any further disturbing the DAQ status. | # If the procedure fails to restore DAQ, call Sergey (DAQ on call) without any further disturbing the DAQ status. | ||
− | + | --> | |
+ | === Locking up the hall === | ||
+ | * Work with the hall work coordinator (Doug Tilles or his designee) to make sure hall is ready for sweep at around 3pm: | ||
+ | ** Vacuum is good, magnet power supplies (Tagger and Torus) are turned ON and in remote mode, LCW is on. | ||
+ | * Make sure experts, beamline, ECal, DC, HTCC, FTOF, and slow controls, checked their systems before the lockup. | ||
+ | * When ready notify MCC to start sweep and lockup of the hall. | ||
+ | * Make sure all necessary monitoring GUIs are up and running. | ||
+ | * Make sure beam viewer screens are up. | ||
+ | * When hall is in "Beam Permit" | ||
+ | ** Ramp torus to 10% of max current (380A) | ||
+ | ** Turn tagger magnet ON if beam tune on the tagger dump or tagger yoke dump will be needed (it will be needed if beam comes back after several hours of down) | ||
+ | ** Turn all beamline devices ON, turn all CLAS12 detectors OFF | ||
===Establishing Acceptable Beam Conditions:=== | ===Establishing Acceptable Beam Conditions:=== | ||
Line 127: | Line 179: | ||
#** Positions on both harps should be within 1mm | #** Positions on both harps should be within 1mm | ||
#** Width on 2C21 should be <~0.1+/-0.05 mm | #** Width on 2C21 should be <~0.1+/-0.05 mm | ||
− | #** Width on tagger harp (2C24) <~0. | + | #** Width on tagger harp (2C24) <~0.5 +/- 0.1mm |
− | #* Halo counters UPS-L/R and TAG-L/T/T2 should be ~few Hz/nA [https://logbooks.jlab.org/entry/3376736] | + | <!--#* Halo counters UPS-L/R and TAG-L/T/T2 should be ~few Hz/nA [https://logbooks.jlab.org/entry/3376736]--> |
<!-- # <b> While MCC degausses the tagger magnet, verify that chicane is ON</b> | <!-- # <b> While MCC degausses the tagger magnet, verify that chicane is ON</b> | ||
#* If not, turn it on. Strictly follow the procedure in the beam line manual!--> | #* If not, turn it on. Strictly follow the procedure in the beam line manual!--> | ||
Line 135: | Line 187: | ||
#* If you don't see it immediately, and rates on halo counters are more than 100 Khz, then ask MCC, to change to pulsed (tune mode) beam, and ask to put corrector values. At this point don't accept any CW beam, until beam spot is visible on Downstream Viewer. | #* If you don't see it immediately, and rates on halo counters are more than 100 Khz, then ask MCC, to change to pulsed (tune mode) beam, and ask to put corrector values. At this point don't accept any CW beam, until beam spot is visible on Downstream Viewer. | ||
#* If MCC operator is not able to tune the beam more than 30 minutes, then please notify RC | #* If MCC operator is not able to tune the beam more than 30 minutes, then please notify RC | ||
− | #* Tune beam profile at CLAS12 target using 2H01A harp. The required beam profile at 2H01A harp is: X-width <~0. | + | #* Tune beam profile at CLAS12 target using 2H01A harp. The required beam profile at 2H01A harp is: X-width <~0.3 mm, Y-width <~ 0.3 mm |
#* Check and log the beam spot on chromax viewer | #* Check and log the beam spot on chromax viewer | ||
#* Check rates on halo counters | #* Check rates on halo counters | ||
#*# UPS-L and UPS-R few Hz/nA, | #*# UPS-L and UPS-R few Hz/nA, | ||
− | #*# The tagger counters should count less than Hz/nA and downstream counters should count ~Hz/nA | + | #*# The tagger counters should count less than Hz/nA and downstream counters should count ~Hz/nA, |
− | #* Once all the above is achieved, turn first CLAS12 ECal HV '''ON''' and monitor and log ECal rates | + | #*# Midstream counters few Hz/nA |
+ | #* Once all the above is achieved, turn first CLAS12 ECal HV '''ON''' and monitor and log ECal rates before bringing rest of the detector UP | ||
=== Setting up the FSD threshold === | === Setting up the FSD threshold === | ||
Line 163: | Line 216: | ||
#* Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook] | #* Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook] | ||
# Perform 2H01A harp scan once per shift or when beam conditions have changed, based on beam monitors (BPMs, halo rates, beam-viewer). During harp scans the HV for DC and HTCC should be OFF. | # Perform 2H01A harp scan once per shift or when beam conditions have changed, based on beam monitors (BPMs, halo rates, beam-viewer). During harp scans the HV for DC and HTCC should be OFF. | ||
− | |||
| valign=top style="background:#eeeeee;"| | | valign=top style="background:#eeeeee;"| | ||
Line 169: | Line 221: | ||
==Every Run:== | ==Every Run:== | ||
# Log screenshots of: | # Log screenshots of: | ||
− | #* main | + | #* main scaler GUI display |
#* Detector occupancy plots | #* Detector occupancy plots | ||
#* Trigger rate gui | #* Trigger rate gui | ||
+ | #* Beam strip charts | ||
|} | |} | ||
Line 187: | Line 240: | ||
* [http://hallbcam02.jlab.org Hall Fisheye] | * [http://hallbcam02.jlab.org Hall Fisheye] | ||
<!--[https://hallbopi.jlab.org/webopi3.3/ Controls WebOpi] (read-only)--> | <!--[https://hallbopi.jlab.org/webopi3.3/ Controls WebOpi] (read-only)--> | ||
+ | |||
+ | | valign=top | | ||
+ | ===Manuals=== | ||
+ | *[https://wiki.jlab.org/clas12-run/images/c/c9/CedManual.pdf CED Manual] | ||
+ | *[https://wiki.jlab.org/clas12-run/images/7/7e/MON12.pdf MON12 Manual] | ||
+ | *[https://wiki.jlab.org/clas12-run/images/5/5a/OfflineKPPmanual2.pdf KPP off-line Manual] | ||
+ | |||
+ | | valign=top | | ||
+ | ===Epics on the web=== | ||
+ | *[https://hallbopi.jlab.org/webopi3.3/w WebOPI] (CUE Login) | ||
+ | |||
|} | |} | ||
Latest revision as of 13:44, 25 July 2024
[edit]
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 KPP run, February 3 to March 3
Beam energy 6.4 GeV (3 pass)
Important: Document all your work in the logbook!
Very Successfull Run
RC: Stepan Stepanyan
- (757) 575-7540
- 9 575 7540 from Counting Room
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
Run Plan for February 4-5, 2017 :
Plan:
Important Notes:
|
General Instructions:Locking up the hall
Establishing Acceptable Beam Conditions:
Setting up the FSD threshold
hpsrun@clonpc11> /home/hpsrun/scripts/FSD/Calc_FSD_Threshold.exe
|
Every Shift:
|
Every Run:
|
---|
Webcams |
Manuals |
Epics on the web
|