Difference between revisions of "Engineering Run"
Jump to navigation
Jump to search
(15 intermediate revisions by 5 users not shown) | |||
Line 9: | Line 9: | ||
===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]=== | ===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]=== | ||
===[https://bta Beam Time Accounting]=== | ===[https://bta Beam Time Accounting]=== | ||
+ | ===[https://www.jlab.org/Hall-B/run-web/comm/ESAD_HallB-CLAS12_rgA.pdf ESAD], [https://www.jlab.org/Hall-B/run-web/comm/COO_HallB-CLAS12_rgA.pdf COO], [https://www.jlab.org/Hall-B/run-web/comm/RSAD_HallB-CLAS12_rgA.pdf RSAD], [https://www.jlab.org/div_dept/train/SAF111/Hall%20B%20worker%20Safety%20Training%20%28SAF111%29%20%2008%2001-12-1.pdf ERG] === | ||
<!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation]=== --> | <!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation]=== --> | ||
Line 73: | Line 74: | ||
</center> | </center> | ||
− | == RC: | + | == RC: Silvia Niccolai == |
− | * (757) 575-7540 | + | * (757) 575-7540 |
* 9 575 7540 from Counting Room | * 9 575 7540 from Counting Room | ||
− | * | + | * silvia@jlab.org |
− | == PDL: | + | == PDL: Maurizio Ungaro == |
* (757) 876-1789 | * (757) 876-1789 | ||
* 9 876-1789 from Counting Room | * 9 876-1789 from Counting Room | ||
− | * | + | * ungaro@jlab.org |
<br> | <br> | ||
Line 91: | Line 92: | ||
* Note 3: Nominal beam positions: '''2C21 (X=0.0 mm, Y=0.0 mm), 2C24 (X=0.0 mm, Y=0.7 mm), 2H01 (X=0.3 mm, Y=-0.6 mm)''' | * Note 3: Nominal beam positions: '''2C21 (X=0.0 mm, Y=0.0 mm), 2C24 (X=0.0 mm, Y=0.7 mm), 2H01 (X=0.3 mm, Y=-0.6 mm)''' | ||
− | * Note 4: With beam to the Faraday Cup, typical rates | + | * Note 4: With beam to the Faraday Cup, typical rates pn all halo counters upstream from the target should be either 0 or of the order of few counts. Count rates in the range of tens or more may indicate bad beam tune or bleed-through from other Halls. |
{| {{TableStyle1}} | {| {{TableStyle1}} | ||
Line 105: | Line 106: | ||
<!--* If beam profiles at the tagger are acceptable, move to beam tuning to the Faraday Cup. Again, refer to the instructions in the "Establish-physics quality beam" procedure at [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf]. Compare harp scan with the one from 1/25 swing shift (https://logbooks.jlab.org/entry/3520947). --> | <!--* If beam profiles at the tagger are acceptable, move to beam tuning to the Faraday Cup. Again, refer to the instructions in the "Establish-physics quality beam" procedure at [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf]. Compare harp scan with the one from 1/25 swing shift (https://logbooks.jlab.org/entry/3520947). --> | ||
<!--* Once beam to Faraday Cup is established, prepare to start data taking. Switch on all detectors; contact expert to switch on SVT. Start trigger studies following instructions from the DAQ expert. --> | <!--* Once beam to Faraday Cup is established, prepare to start data taking. Switch on all detectors; contact expert to switch on SVT. Start trigger studies following instructions from the DAQ expert. --> | ||
− | * Take data with PROD/elec_htcc_1phe_pcal_300.trg at | + | * Take 2 hour data runs with PROD/elec_htcc_1phe_pcal_300.trg at 30 nA with the following DC HV and thresholds: |
− | * | + | ** R1: #9/-45 mV, R2: #10/-65 mV, R3: #10/-60 mV |
− | * | + | ** R1: #8/-30 mV, R2: #10/-65 mV, R3: #9/-45 mV |
+ | ** R1: #8/-30 mV, R2: #9/-45 mV, R3: #9/-45 mV | ||
+ | * Take data at 35 nA with PROD/elec_htcc_1phe_pcal_300.trg until morning; runs should be 2 hrs in length. Use R1: #8/-30 mV, R2: #9/-45 mV, R3: #9/-45 mV | ||
* Hall B work for Monday: | * Hall B work for Monday: | ||
** Ramp down solenoid (torus can stay up) (RC) | ** Ramp down solenoid (torus can stay up) (RC) | ||
+ | ** Empty the hydrogen target (Hall B Engineering) | ||
** Complete shielding addition outside scattering chamber (Hall B Engineering) | ** Complete shielding addition outside scattering chamber (Hall B Engineering) | ||
** Restore beamline (Hall B Engineering) | ** Restore beamline (Hall B Engineering) | ||
− | ** Replace FT-Hode mezzanine board (N. | + | ** Replace FT-Hode mezzanine board (N. Zachar) |
** Work on DC cable swaps (M. Cook + M. Mestayer) | ** Work on DC cable swaps (M. Cook + M. Mestayer) | ||
** Work on vacuum gauge (D. Anderson) | ** Work on vacuum gauge (D. Anderson) | ||
Line 202: | Line 206: | ||
===Hall-B=== | ===Hall-B=== | ||
* [https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc Operation Safety Procedures] | * [https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc Operation Safety Procedures] | ||
− | * [https://clasweb.jlab.org/wiki/index.php/Engineering_Run_Analysis | + | * [https://wiki.jlab.org/clas12-run/index.php/Run_Group_A Run Group A Wiki] |
+ | * [https://clasweb.jlab.org/wiki/index.php/Run_Group_A Run Group A Analysis Wiki] | ||
+ | * [https://clasweb.jlab.org/wiki/index.php/Engineering_Run_Analysis Engineering Run Analysis Wiki] | ||
* [http://clasweb.jlab.org/rcdb RCDB] | * [http://clasweb.jlab.org/rcdb RCDB] | ||
| valign=top | | | valign=top | |