Difference between revisions of "Engineering Run"
Jump to navigation
Jump to search
Line 109: | Line 109: | ||
** 30 nA. 10M events with DC in the trigger: DAQ configuration PROD, trigger file dc_elec_htcc_1phe_pcal_300.trg | ** 30 nA. 10M events with DC in the trigger: DAQ configuration PROD, trigger file dc_elec_htcc_1phe_pcal_300.trg | ||
** 30 nA. 10M events without DC in the trigger: DAQ configuration PROD, trigger file dcno_elec_htcc_1phe_pcal_300.trg | ** 30 nA. 10M events without DC in the trigger: DAQ configuration PROD, trigger file dcno_elec_htcc_1phe_pcal_300.trg | ||
− | ** 10 nA. | + | ** 10 nA. 2M events with DC in the trigger: DAQ configuration PROD, trigger file dc_elec_htcc_1phe_pcal_300.trg |
− | ** 10 nA. | + | ** 10 nA. 2M events without DC in the trigger: DAQ configuration PROD, trigger file dcno_elec_htcc_1phe_pcal_300.trg |
− | ** 5 nA. | + | ** 5 nA. 2M events with DC in the trigger: DAQ configuration PROD, trigger file dc_elec_htcc_1phe_pcal_300.trg |
− | ** 5 nA. | + | ** 5 nA. 2M events without DC in the trigger: DAQ configuration PROD, trigger file dcno_elec_htcc_1phe_pcal_300.trg |
** Continue regular data taking with PROD/elec_htcc_1phe_pcal_300.cnf at 5 nA until 3 am; 2 hours long runs. | ** Continue regular data taking with PROD/elec_htcc_1phe_pcal_300.cnf at 5 nA until 3 am; 2 hours long runs. | ||
** At the time, RICH studies will begin under the guidance of the RICH group. Use PROD6/elec_htcc_1phe_pcal_300.cnf at 50 nA. Continue until 5 am. | ** At the time, RICH studies will begin under the guidance of the RICH group. Use PROD6/elec_htcc_1phe_pcal_300.cnf at 50 nA. Continue until 5 am. |
Revision as of 20:09, 30 January 2018
[edit]
Shift ScheduleShift ChecklistHot CheckoutBeam Time Accounting |
Manuals |
Procedures |
JLab Logbooks
|
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 Engineering Run, Winter 2018
Beam energy 10.6 GeV (5 pass)
Important: Document all your work in the logbook!
Remember to fill in the run list at the beginning and end of each run (clas12run@gmail.com can fill the run list)
RC: Raffaella De Vita
- (757) 575-7540
- 9 575 7540 from Counting Room
- devita@jlab.org
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
- pasyuk@jlab.org
- Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.
- Note 2: At the end of each run, follow the DAQ restart sequence "end run", "abort", "reset", "download", "prestart", "go". After DAQ prestart is complete reboot the scaler IOCs with the command: iocjscalerRestartAll.sh. Note: After each step, make sure it is complete in the Run Control message window. If a roc has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
- Note 3: Nominal beam positions: 2C21 (X=0.0 mm, Y=0.0 mm), 2C24 (X=0.0 mm, Y=0.7 mm), 2H01 (X=0.3 mm, Y=-0.6 mm)
- Note 4: With beam to the Faraday Cup, typical rates an all halo counters upstream from the target should be either 0 or of the order of few counts. Count rates in the range of tens or more may indicate bad beam tune or bleed-through from other Halls.
Run Plan:(last update 1/30 - 12:30 pm)
|
General Instructions:
Every Shift:
Every Run:
|
Webcams |
Manuals |
Epics on the web
|
Hall-B |
Accelerator |
Bluejean meetings |