Difference between revisions of "Run Group M"

From clas12-run
Jump to navigation Jump to search
 
(262 intermediate revisions by 7 users not shown)
Line 6: Line 6:
 
<!--==={{#switchtablink:Phone Numbers|'''Phone Numbers'''}}===-->
 
<!--==={{#switchtablink:Phone Numbers|'''Phone Numbers'''}}===-->
 
===[http://www.jlab.org/Hall-B/shifts Shift Schedule]===
 
===[http://www.jlab.org/Hall-B/shifts Shift Schedule]===
===[https://www.jlab.org/Hall-B/run-web/index_rgm.html  ESAD, COO, RSAD Read before shift!!!]===
+
===[https://logbooks.jlab.org/book/hallb Hall B Logbook]===
 
===[https://logbooks.jlab.org/checklists/151 Shift Checklist] ===
 
===[https://logbooks.jlab.org/checklists/151 Shift Checklist] ===
 
===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]===
 
===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]===
 
===[https://bta Beam Time Accounting]===
 
===[https://bta Beam Time Accounting]===
* See guidance for BTA in '''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf Beam Time Accounting User Guide]'''.
+
* See guidance at '''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf BTA User Guide]'''.
 
<!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation] === -->
 
<!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation] === -->
 +
===[https://www.jlab.org/Hall-B/run-web/rgm/ESAD_HallB-CLAS12_rgM.pdf ESAD], [https://www.jlab.org/Hall-B/run-web/rgm/COO_HallB-CLAS12_RGM.pdf COO], [https://www.jlab.org/Hall-B/run-web/rgm/RSAD_HallB-CLAS12_rgM.pdf RSAD], [https://www.jlab.org/div_dept/train/SAF111/Hall%20B%20worker%20Safety%20Training%20%28SAF111%29%20%2008%2001-12-1.pdf ERG] ===
  
 
| valign=top |
 
| valign=top |
Line 28: Line 29:
 
* [https://github.com/JeffersonLab/clas12-manuals/blob/master/ft/FT-Manual.pdf FT]
 
* [https://github.com/JeffersonLab/clas12-manuals/blob/master/ft/FT-Manual.pdf FT]
 
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/beamline/manual/beamline_manual.pdf Beamline]
 
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/beamline/manual/beamline_manual.pdf Beamline]
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf Torus Power-Up and Power-Down Procedure]
+
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf Torus Power-Up/Down Procedure]
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf Solenoid Power-Up and Power-Down Procedure]
+
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf Solenoid Power-Up/Down Procedure]
 
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/target/Target_Shift_Worker_RGM_2021.pdf Target Operation manual]
 
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/target/Target_Shift_Worker_RGM_2021.pdf Target Operation manual]
 
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/daq/opman_master.pdf DAQ]
 
* [https://github.com/JeffersonLab/clas12-manuals/raw/master/daq/opman_master.pdf DAQ]
Line 41: Line 42:
 
* [[Media:HarpScanManual.pdf|Performing Harp Scans]]
 
* [[Media:HarpScanManual.pdf|Performing Harp Scans]]
 
* [https://wiki.jlab.org/hps-run/images/0/0c/Accessing_the_tunnel.pdf Tunnel/Hall Access]
 
* [https://wiki.jlab.org/hps-run/images/0/0c/Accessing_the_tunnel.pdf Tunnel/Hall Access]
* [https://www.jlab.org/Hall-B/run-web/index_rgm.html  ESAD, COO, RSAD Read before shift!!!]
+
* [https://www.jlab.org/Hall-B/run-web/index_rgm.html  ESAD, COO, RSAD]
 
<!--* [https://clonwiki0.jlab.org/wiki/index.php/DAQ/Online_Quick_Reference <span style="color:red;"><b>DAQ Quick Reference/Recovery</b></span>] -->
 
<!--* [https://clonwiki0.jlab.org/wiki/index.php/DAQ/Online_Quick_Reference <span style="color:red;"><b>DAQ Quick Reference/Recovery</b></span>] -->
  
Line 66: Line 67:
 
<!-- JUST MODIFY AND SAVE ANYTHING IN THIS COMMENT BLOCK TO FORCE A REFRESH OF THE PHONE NUMBERS TEMPLATE -->
 
<!-- JUST MODIFY AND SAVE ANYTHING IN THIS COMMENT BLOCK TO FORCE A REFRESH OF THE PHONE NUMBERS TEMPLATE -->
  
 +
 +
<!--#######################################  Short Term Schedule  #############################################-->
 
= Short Term Schedule =
 
= Short Term Schedule =
<center><font color=blue size=4>
+
 
''' CLAS12 Run Group M, Fall 2021 </font> '''<br>
+
=== <font color=blue size=4> ''' CLAS12 Run Group M, Fall 2021 </font> ''' ===
 
''' Beam energies: 2.1, 4.0, 6.0 GeV (1.96 GeV/pass) '''<br>
 
''' Beam energies: 2.1, 4.0, 6.0 GeV (1.96 GeV/pass) '''<br>
''' Important: Document all your work in the logbook! '''<br>
 
  
<!--
+
=== RC: Susan Schadmand ===
*'''<font color=red size=6> Shifts are cancelled until 08:00 Saturday September 22, 20XX </font>'''<br>
+
* (757) 575-7540, [mailto:susansch@jlab.org susansch@jlab.org]
-->
+
* 9 575 7540 from Counting Room 
</center>
 
  
== RC: Stephen Bueltmann ==
+
=== PDL: Valery Kubarovsky ===
* (757) 575-7540 
 
* 9 575 7540 from Counting Room
 
* [mailto:bueltman@jlab.org bueltman@jlab.org]
 
 
 
== PDL: Eugene Pasyuk ==
 
 
*  (757) 876-1789  
 
*  (757) 876-1789  
 
* 9 876-1789 from Counting Room
 
* 9 876-1789 from Counting Room
* [mailto:pasyuk@jlab.org pasyuk@jlab.org]
+
* [mailto:vpk@jlab.org vpk@jlab.org]
  
 +
== <font color=blue>''' Run Plan: Friday, Feb 7-8, 2022 '''</font> ==
  
== <font color=blue>''' Run Plan: Dec 15 - Dec 21 2021 '''</font>==
+
Production runs use <b> PROD67_noVTPread </b> and the trigger <b> rgm_6GeV_inb_v1_0.trg </b>.<br/>  
 +
Run duration 100M events or 4 hours, whichever comes first.
  
<b> PROD67_noVTPread </b> and the trigger <b>rgm_6GeV_inb_v1_0.trg</b>.<br/> Run duration should be no more than 100M events or 4 hours, whichever comes first.
+
* run 6GeV 80 nA on Ca48 target (240 mg/cm2), beam blocker IN, until SAD
  
<b>Summary</b>
+
* low luminosity runs:(ca 3pm - 9pm on Feb 7)
* Take 2H data at 50 nA
+
** 2 hrs 5nA
* Friday 7:30, switch to 4He target
+
** 2 hrs 10 nA
** call MCC and ask for Controlled Access
+
** 2 hrs 40 nA
** warm up target with set point = 100 K
 
* Establish beam, probably during the second half for day shift
 
** follow procedures to restore beam
 
** check DC occupancy at 60 nA  
 
** check beam blocker calibration
 
** take data at 60 nA until the end of 2021 run
 
* 2021 data taking ends on Tuesday, December 21, at 7:00
 
<br>
 
  
{| {{TableStyle1}}
+
* the run on Ca48 until 6am, Feb 8
  
| valign=top width=50% |
+
* 6am Feb 8: Investigate BLA tune beam trips with tune beam to Hall B, https://devweb.acc.jlab.org/CSUEApps/atlis/task/24015
  
 +
* RC will be there at 6 am and follow Eugene's instruction
 +
** put the blank collimator in
 +
** turn HV off for all tracking detectors, just in case if the tagger magnet trips during the test
 +
** MCC may mask upstream halo FSD if necessary but keep all other FSD unmasked
  
 
== <font color=blue> DAQ configuration </font> ==  
 
== <font color=blue> DAQ configuration </font> ==  
<b> PROD67_noVTPread </b>, production trigger <b> rgm_6GeV_inb_v1_0.trg </b>
+
 
 +
<b> PROD67_noVTPread </b>, production trigger <b> rgm_6GeV_inb_v1_0.trg </b>. <br/>
 +
 
 +
<font color=blue><b> NOTE: UNLESS a RICH problem crashes the DAQ, do NOT interrupt an otherwise smooth run to do a RICH recovery - instead do this in between runs.  </b></font>
 +
<br/>
 +
 
 +
<font color=blue><b> NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms at least once every 30-60 minutes to make sure there are no major detector problems. </b></font>
 +
<br/>
  
 
<b> At the end of each run, follow the <font color=red>STANDARD DAQ RESTART SEQUENCE</font> </b>'''<br>
 
<b> At the end of each run, follow the <font color=red>STANDARD DAQ RESTART SEQUENCE</font> </b>'''<br>
Line 122: Line 123:
 
* After each step, make sure it is completed in the Run Control message window.</font></b> If a ROC has crashed, find which one it is, issue a roc_reboot command ON JUST THAT ROC and try again. Contact the DAQ expert if there are any questions.
 
* After each step, make sure it is completed in the Run Control message window.</font></b> If a ROC has crashed, find which one it is, issue a roc_reboot command ON JUST THAT ROC and try again. Contact the DAQ expert if there are any questions.
  
 +
== <font color=blue> References and Standards </font>==
 +
''(last update 01/18/2022- 23:30)''
 +
 +
<b> Nominal Beam Positions </b>
 +
*2H01, X: -0.6 mm, Y: 0.8 mm
 +
*2C24, X: -2.0 mm, Y: +0.6 mm
 +
 +
<b> FSD Thresholds </b>
 +
* Upstream: 2000 Hz
 +
* Midstream: 2000 Hz
 +
* Downstream: 500000 Hz
 +
* BOM: 10000
 +
* 5 ms dwell time
 +
 +
<b> Reference Harp Scans for Beam on Faraday Cup: </b> 2H01  [https://logbooks.jlab.org/entry/3963256]
  
== <font color=blue>''' Announcements'''</font>==
+
<b> Reference Harp Scans for Beam on Tagger dump: </b> 2C21 [https://logbooks.jlab.org/entry/3963244], tagger harp [https://logbooks.jlab.org/entry/3963250]
  
* If any weird stripes appear in the DC occupancy plots, call Sergey. This is a known problem.
+
<b> Reference Monitoring Histograms:</b>
* Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.
+
* [https://logbooks.jlab.org/entry/3982817 6 GeV 80 nA on Ca48]
The integrated rates on the upstream counters have to be in the range 0-15 Hz (rates up to 100 Hz are acceptable) and the rates on the midstream counters have to be in the range 10-20 Hz (acceptable up to 50 Hz) @50 nA. Counting rates in the range of hundreds of Hz may indicate a bad beam tune or bleed-through from other Halls.
+
* [https://logbooks.jlab.org/entry/3980929 6 GeV 90 nA on Sn]
<!--
+
* [https://logbooks.jlab.org/entry/3973807 6 nA, production C]
* Note 2: At the end of each run, follow the standard DAQ restart sequence
+
* [https://logbooks.jlab.org/entry/3943458 50 nA, production LD2]
"end run", "cancel", "reset", then if the run ended correctly, "download", "prestart", "iocjscalerRestartAll.sh", "go". If the run did not end correctly or if any ROCs had to be rebooted, "configure", "download", "prestart", "iocjscalerRestartAll.sh", "go".
 
  
After each step, make sure it is complete in the Run Control message window. If a ROC has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
+
<b> Counter rates </b>
-->
+
* Upstream counters integrated rates: 0-15 Hz (acceptable up to 100 Hz are acceptable) @50 nA.
 +
* Midstream counters: 10-20 Hz (acceptable up to 50 Hz) @50 nA.
 +
* Counting rates of ~ hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.
  
 +
<b> Beamline vacuum: </b> should be not higher than 5e-5.
  
* Note 3: Do not turn OFF FTOF HVs, even during the beam tune with CW beam (turn off if tuned/pulsed beam in the upstream beamline)
+
= Notes/Known Issues =
 +
<!--#######################################  Notes/Known Issues  ################################################-->
  
* Note 4: In case of a Torus and/or Solenoid Fast Dump do the following:
+
'''NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms (mon12) at least once every 30-60 minutes to make sure there are no major detector problems.'''
*# Notify MCC to request beam OFF and to drop Hall B status to Power Permit
 
*# Call Engineering on-call
 
*# Make a separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Probir Goshal, Dave Kashy, and esr-users@jlab.org
 
*# Notify Run Coordinator
 
*# Turn off all detectors
 
  
*Note 5: When the beam is being delivered to the Faraday Cup:
+
== <font color=blue> Notes </font> ==
*# the Fast Shut Down elements: Upstream, Midstream, Downstream, BOM, and Solenoid should always be in the state <font color=red>UNMASKED</font>
 
*# No changes to the FSD threshold should be made without RC or beamline expert approval
 
  
*Note 6: Any request for a special run or change of configuration has to be approved by the RC & documented
+
#'''LTCC''' is NOT used in this experiment. HV should be kept OFF.
 +
# '''FMT''' only using 3 FMT layers, not 6.
 +
# The main lights in the Hall ('''dome lights''') and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during access, they should be switched off when leaving the Hall. Refer to these photos:
 +
#* ON: [https://logbooks.jlab.org/entry/3825712]
 +
#* OFF: [https://logbooks.jlab.org/entry/3825731]
 +
#* Note that the dome lights when switched off cannot be turned back on immediately because they require 10-15 min to cool down.
 +
# In case of a '''Torus and/or Solenoid Fast Dump''' do the following:
 +
#* Notify MCC to request beam OFF and to drop Hall B status to Power Permit
 +
#* Call Engineering on-call
 +
#* Make a separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Probir Goshal, Dave Kashy, and esr-users@jlab.org
 +
#* Notify Run Coordinator
 +
#* Turn off all detectors
 +
# Observe the guidance of the alarm handler.
  
*Note 7: * [https://bta.acc.jlab.org Fill out BTA] hourly.  Click "Load from EPICS" to automatically fill the left side then correct as needed.
 
  
*Note 8: Reset CLAS12MON frequently to avoid histogram saturation.
 
  
*Note 9: If crate ADCBAND was rebooted: Contact BAND expert and make a note in the HBBAND logbook and in HBLOG.
+
== <font color=blue> Known Issues </font> ==
  
*Note 10: ECAL HV SEC2_WI_E36 is known to be problematic. Channel stays off for now.
+
* '''Beamline overview''' No Data from Faraday cup viewer camera, network switch died
  
*Note 11: LTCC is NOT used in this experiment. HV should be kept OFF.
+
* '''DAQ''' when starting a run, the live time alarm goes off, while status of the ROCs all ok, then the alarm can just be acknowledged
 +
* '''DAQ''' The error messages " ERR: event# ..." e.g. for crates tdcband1, tdcecal1 and tdcecal6 are NOT a problem. Can go along with relatively higher roc rates.
  
<!--
+
* '''PCAL''' transient: mu strip occupancy hole in U view TDC, https://logbooks.jlab.org/entry/3978499, https://logbooks.jlab.org/entry/3978736
*Note 11: Shift workers must check the occupancies! Use this tool to compare to previous runs: [https://clas12mon.jlab.org/mon12/histograms/ https://clas12mon.jlab.org/mon12/histograms/]
+
* '''ECAL''' one strip of TDC ECout W strip sector4 is hot, https://logbooks.jlab.org/entry/3979286
 +
* '''ECAL''' HV SEC2_WI_E36 is known to be problematic. Channel stays off for now.
  
-->
+
* '''BMT''' off: histogram occupancy Z, layer 3, sector 1, detetcor 7, S1L3 strip HV is off due to high leakage, https://logbooks.jlab.org/entry/3970886
 +
* '''BMT''' off: histogram occupancy Z, layer 5, sector 2, detetcor 14
 +
* '''BMT''' SEC1 L1 STRIP: reduced HV. (This tile will have almost 0 efficiency), https://logbooks.jlab.org/entry/3982425
  
*Note 12: If responding to RICH or Trigger alarms please post screens also to RICH or HBTRIGGER logbook, respectively.
+
* '''RICH''' recovery only between runs. also when you see problems like a missing tile
 +
* '''RICH''' FPGA temperatures can show yellow tiles. Yellow tiles in the RICH temperature map are normal. It is done just to pay attention to the tiles with temp>70 degrees. The alarm is set to 75 degrees https://logbooks.jlab.org/entry/3975547
  
*Note 13: Do a RICH recovery (press the RICH Recovery button on the GUI) once daily during the day shift between runs.
+
= Shift Expert =
 +
<!--#######################################  Shift Expert  ################################################-->
 +
{| {{TableStyle1}}
 +
| valign=top |
  
*Note 14: Cycle the FMT Gas once per shift.  If done rapidly without pausing (Gas "stop"-"yes"-"start"-"yes"), the HV should not crash.
+
'''NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms at least once every 30 - 60 minutes to make sure there are no major detector problems.'''
  
 +
* Follow the '''[[https://wiki.jlab.org/clas12-run/index.php/Run_Group_M#Short_Term_Schedule Short Term Schedule]]''' as outlined by RC
 +
** includes Run Plan, DAQ configuration, and References and Standards
 +
* Keep '''shift summary''' up to date in HBLOG. Record all that happens.
  
== <font color=blue>''' References and Standards:'''</font>==
+
* '''Cycle the FMT gas once per shift''', in-between runs. Pease log in shift summary. 
''(last update 12/14/2021- 22:10)''
+
** If it is not reset, the interlock may drop and disable the HV.
 +
** Turning off and on the  gas flow without pausing to avoid HV trips.
 +
** If the HV tripped, make sure that once gas flow is restarted and the flow differential is down to reasonable values, to turn the FMT HV back on and let it ramp all the way up.
 +
** Remember that this experiment is only using 3 FMT layers, not 6.
  
<b> Nominal Beam Positions </b>
+
* Do a '''RICH recovery''' (press the RICH Recovery button on the GUI) once daily during day shift, between runs. Please log in shift summary.
*2H01, X: -0.6 mm, Y: -0.2 mm
+
** Note the automated "RICH Recovery" sequence already confirms RICH4 is up and accepting ssh connections before claiming success. And it also prints out that you have to "Cancel->Reset->Configure->Download->Prestart" before starting the next run.
*2C24, X: -2.0 mm, Y: +0.6 mm
 
  
<b> FSD Thresholds </b>
+
* '''[https://bta.acc.jlab.org Fill out BTA]''' hourly.  Click "Load from EPICS" to automatically fill the left side then correct as needed.
* Upstream: 2000 Hz
+
** Accelerator beam time:
* Midstream: 2000 Hz
+
*** ABU: acceptable beam used (eg harp scans, calibrations, trigger settings, running)
* Downstream: 500000 Hz
+
*** BANU: beam acceptable but not used (eg radiator change or our problems)
* BOM: 10000
+
*** BNA: beam not acceptable (eg tuning, drifting, not focused)
* 5 ms dwell time
+
** Experiment beam time
 +
*** ER: experiment ready
 +
*** PCC: planned configuration change (when beam is masked while radiators are moved, DAQ (roc rebooting,  restarting runs)), if more than 5 minutes, put a short comment, eg harp scans or DAQ.
 +
*** UED: unplanned experiment down (hardware failure)
  
<b> Reference Harp Scans for Beam on Faraday Cup: </b> 2H01  [https://logbooks.jlab.org/entry/3963256]
 
  
<b> Reference Harp Scans for Beam on Tagger dump: </b> 2C21 [https://logbooks.jlab.org/entry/3963244], tagger harp [https://logbooks.jlab.org/entry/3963250]
+
'''In case of other questions or uncertainties of what to do, call the RC or PDL'''
  
<b> Reference Monitoring Histograms (80 nA, production Ca-48) </b> [https://logbooks.jlab.org/entry/3958508]
+
(remote) shift worker: see dedicated [https://wiki.jlab.org/clas12-run/index.php/Run_Group_M#tab=Remote_Shifts Remote Shifts] tab above.
<b> Old reference Monitoring Histograms (50 nA, production LD2) </b> [https://logbooks.jlab.org/entry/3943458]
 
  
<b> Counter rates </b>
+
|}
* Upstream counters integrated rates: 0-15 Hz (acceptable up to 100 Hz are acceptable) @50 nA.
 
* Midstream counters: 10-20 Hz (acceptable up to 50 Hz) @50 nA.
 
* Counting rates of ~ hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.
 
  
<b> Beamline vacuum: </b> should be not higher than 5e-5.
+
= Remote Worker Shift =
  
 +
{| {{TableStyle1}}
  
 
| valign=top |
 
| valign=top |
  
==<font color=blue>''' General Instructions''':</font>==
 
* The main lights in the Hall (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during access, they should be switched off when leaving the Hall. <b> Refer to these photos!</b>
 
* ON: [https://logbooks.jlab.org/entry/3825712]
 
* OFF: [https://logbooks.jlab.org/entry/3825731]
 
  
Note that the dome lights when switched off cannot be turned back on immediately because they require 10-15 min to cool down.
+
* '''Zoom for 24-7 communication with counting house:'''  https://jlab-org.zoomgov.com/j/1619881100
* Do not run more than 30 minutes with >150 W beam to Faraday cup without the beam blocker.
+
** Passcode REQUIRED: 927417
* Turn DC HV off only for beam tuning; if no beam is available or when the beam is stable, keep them on even if you are not taking data.
+
* Remind the expert in the counting house to restart their zoom, if necessary
* In case of loss of communication with IOCBTARG, follow instructions at https://logbooks.jlab.org/entry/3502218
+
 
* Check that no unnecessary beamline-related screens are open. This includes particularly the big beamline overview screen, but also and any motor/harp/collimator screens, and IOC health screens.
+
* Remote VNC connection instructionshttps://logbooks.jlab.org/entry/3906039
<!-- * With any issue contact On-Call Experts or RC - do not spend more than 15-20 min trying to fix the problem.  
+
** All necessary applications should be avaible from the desktop menu (left/right click on the desktop)
* All jscaler iocs (iocjscalerX) on the health screen (under DAQ tab) must be restarted after every DAQ prestart is completed. Follow this link for detailed instructions https://userweb.jlab.org/~baltzell/CLAS12/SC/jlabScalersOps.txt
+
* EPICS GUIs should be accessed '''ONLY''' via the desktop menu or by running <tt>clascss-remote</tt>.
-->
+
* [https://userweb.jlab.org/~baltzell/clas12/shift/remote-demo.mp4 Remote Demonstration Video (150 MB)]
 +
 
 +
 
 +
=== Tasks ===
 +
 
 +
 
 +
'''Every Run:'''
 +
 
 +
* WITH BEAM, log screen shots of
 +
** Beamline Overview, in VNC or [https://hallbopi.jlab.org/webopi3.3/w?opi=beamline/clas12-web.opi Web Browser]
 +
** CLAS12 Trigger rates and DAQ status
 +
 
 +
* upload monitoring plots (mon12) to logook
 +
** '''look at the spectra''': Reference, current, and 5 most recent runs, choose a reference run (the reference numbers refer to logbook entries):
 +
*** 6 GeV 80 nA on Ca48 [https://clas12mon.jlab.org/mon12/histograms/?reference=3982817 https://clas12mon.jlab.org/mon12/histograms/?reference=3982817]
 +
*** 6 GeV 90 nA on Sn [https://clas12mon.jlab.org/mon12/histograms/?reference=3980929 https://clas12mon.jlab.org/mon12/histograms/?reference=3980929]
 +
*** ref 6 nA, production C, [https://clas12mon.jlab.org/mon12/histograms/?reference=3973807 https://clas12mon.jlab.org/mon12/histograms/?reference=3973807]
 +
*** ref 50 nA, production LD2, [https://clas12mon.jlab.org/mon12/histograms/?reference=3943458 https://clas12mon.jlab.org/mon12/histograms/?reference=3943458]
 +
 
 
'''Every Shift:'''
 
'''Every Shift:'''
* Follow the run plan as outlined by RC
 
* If any concern about beam stability, ask MCC if orbit locks are on (they should be).
 
* Keep shift summary up to date in HBLOG. Record all that happens.
 
* Document any beam condition change and send scaler GUIs to HBLOG
 
* Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook]
 
* Cycle the FMT gas once per shift  '''in-between runs!''' Turning off and on the  gas flow without pausing to avoid HV trips. If the HV tripped, make sure that once gas flow is restarted and the flow differential is down to reasonable values, to turn the FMT HV back on and let it ramp all the way up. Remember that this experiment is only using 3 FMT layers, not 6.
 
  
 +
* Fill the [https://logbooks.jlab.org/checklists/151 shift checklist]
 +
 +
* Log screen shots of RICH temperature and scaler maps. Log in HBLOG and RICH logbook.
 +
 +
'''Regularly''':
 +
 +
* <font color=red>'''reset & check spectra frequently (every 30 - 60 minutes)'''</font>
 +
** Some plots in '''mon12''' have a '''choice of histogram sets per sector''', select buttons at the bottom of the plot. Only the currently selected set ends up in the logbook entry.
 +
** that means you have to '''look at all sectors for these histograms'''
  
'''Every Run:'''
+
* Log the '''strip charts''' in time intervals '''according to the x-axis time span''', using the liveplot configuration '''Beamline4Logbook''', see https://logbooks.jlab.org/entry/3978837 .
 +
** in VNC: use CS-Studio, Tools, Strip Charts, livePlot
 +
*** right-click on the livePlot screen and select "Load a Configuration"
 +
*** the configuration "Beamline4Logbook" provides the beam current and position information
 +
*** right-click on the screen and select "Make Elog Entry", make sure to log to HBLOG and not ELOG
 +
 
 +
* in Web Browser: [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Upstream+and+Midstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scaler_cS3b&pv=scaler_cS4b&pv=scaler_cS6b&pv=scaler_cS12b&pv=scaler_cS13b&pv=scaler_cS14b&pv=scaler_cS15b&scaler_cS3blabel=scaler_cS3b&scaler_cS3bcolor=%23a6cee3&scaler_cS3byAxisLabel=Rate++%28Hz%29&scaler_cS3byAxisMin=&scaler_cS3byAxisMax=&scaler_cS3byAxisLog&scaler_cS3bscaler=&start=2020-08-08+09%3A02%3A36&end=2020-08-08+09%3A07%3A36&scaler_cS4blabel=scaler_cS4b&scaler_cS4bcolor=%231f78b4&scaler_cS4byAxisLabel=&scaler_cS4byAxisMin=&scaler_cS4byAxisMax=&scaler_cS4byAxisLog=&scaler_cS4bscaler=&scaler_cS5byAxisLabel=&scaler_cS5byAxisMin=&scaler_cS5byAxisMax=&scaler_cS5byAxisLog=&scaler_cS5bscaler=&scaler_cS6blabel=scaler_cS6b&scaler_cS6bcolor=%2333a02c&scaler_cS6byAxisLabel=&scaler_cS6byAxisMin=&scaler_cS6byAxisMax=&scaler_cS6byAxisLog=&scaler_cS6bscaler=&scaler_cS7byAxisLabel=&scaler_cS7byAxisMin=&scaler_cS7byAxisMax=&scaler_cS7byAxisLog=&scaler_cS7bscaler=&scaler_cS12blabel=scaler_cS12b&scaler_cS12bcolor=%23e31a1c&scaler_cS12byAxisLabel=&scaler_cS12byAxisMin=&scaler_cS12byAxisMax=&scaler_cS12byAxisLog=&scaler_cS12bscaler=&scaler_cS13blabel=scaler_cS13b&scaler_cS13bcolor=%23fdbf6f&scaler_cS13byAxisLabel=&scaler_cS13byAxisMin=&scaler_cS13byAxisMax=&scaler_cS13byAxisLog=&scaler_cS13bscaler=&scaler_cS14blabel=scaler_cS14b&scaler_cS14bcolor=%23ff7f00&scaler_cS14byAxisLabel=&scaler_cS14byAxisMin=&scaler_cS14byAxisMax=&scaler_cS14byAxisLog=&scaler_cS14bscaler=&scaler_cS15blabel=scaler_cS15b&scaler_cS15bcolor=%23cab2d6&scaler_cS15byAxisLabel=&scaler_cS15byAxisMin=&scaler_cS15byAxisMax=&scaler_cS15byAxisLog=&scaler_cS15bscaler= Upstream/Midstream Halo Counters], [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Downstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scalerS8b&pv=scalerS9b&scalerS8blabel=scalerS8b&scalerS8bcolor=%23a6cee3&scalerS8byAxisLabel=Rate++%28Hz%29&scalerS8byAxisMin=&scalerS8byAxisMax=&scalerS8byAxisLog&scalerS8bscaler=&pv=scalerS10b&pv=scalerS11b&scalerS9blabel=scalerS9b&scalerS9bcolor=%231f78b4&scalerS9byAxisLabel=&scalerS9byAxisMin=&scalerS9byAxisMax=&scalerS9byAxisLog=&scalerS9bscaler=&scalerS10blabel=scalerS10b&scalerS10bcolor=%23b2df8a&scalerS10byAxisLabel=&scalerS10byAxisMin=&scalerS10byAxisMax=&scalerS10byAxisLog=&scalerS10bscaler=&scalerS11blabel=scalerS11b&scalerS11bcolor=%2333a02c&scalerS11byAxisLabel=&scalerS11byAxisMin=&scalerS11byAxisMax=&scalerS11byAxisLog=&scalerS11bscaler= Downstream Halo Counters], [https://epicsweb.jlab.org/wave/?start=2020-07-08+16%3A50%3A02&end=2020-07-08+16%3A55%3A02&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Beam+Currents&fullscreen=false&layoutMode=2&viewerMode=2&pv=IPM2C21A&pv=IPM2C24A&pv=scaler_calc1b&IPM2C21Alabel=IPM2C21A&IPM2C21Acolor=%23a6cee3&IPM2C21AyAxisLabel=Beam+Current+%28nA%29&IPM2C21AyAxisMin=0&IPM2C21AyAxisMax=300&IPM2C21AyAxisLog&IPM2C21Ascaler=&scaler_calc1blabel=Faraday+Cup&scaler_calc1bcolor=%23b2df8a&scaler_calc1byAxisLabel=&scaler_calc1byAxisMin=&scaler_calc1byAxisMax=&scaler_calc1byAxisLog&scaler_calc1bscaler= Beam Currents], [https://epicsweb.jlab.org/wave/?start=2020-08-03+12%3A30%3A57&end=2020-08-03+12%3A35%3A57&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=BPM+Positions+%28Y-Axis+is+mean+%2B%2F-+0.5+mm%29&fullscreen=false&layoutMode=3&viewerMode=2&pv=IPM2C24A.XPOS&pv=IPM2C24A.YPOS&pv=IPM2H01.XPOS&pv=IPM2H01.YPOS&IPM2C24A.XPOSlabel=IPM2C24A.XPOS&IPM2C24A.XPOScolor=%23e31a1c&IPM2C24A.XPOSyAxisLabel=&IPM2C24A.XPOSyAxisMin=-2.0&IPM2C24A.XPOSyAxisMax=+1.0&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=pink&IPM2C24A.YPOSyAxisLabel=&IPM2C24A.YPOSyAxisMin=-2.0&IPM2C24A.YPOSyAxisMax=1.0&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=darkgreen&IPM2H01.XPOSyAxisLabel=&IPM2H01.XPOSyAxisMin=-2.0&IPM2H01.XPOSyAxisMax=1.0&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=lightgreen&IPM2H01.YPOSyAxisLabel=&IPM2H01.YPOSyAxisMin=-2.0&IPM2H01.YPOSyAxisMax=1.0&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler=#a6cee3&IPM2C24A.XPOSyAxisLabel=2C24+X+(mm)&IPM2C24A.XPOSyAxisMin=-1.5&IPM2C24A.XPOSyAxisMax=-0.5&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=%231f78b4&IPM2C24A.YPOSyAxisLabel=2C24+Y+(mm)&IPM2C24A.YPOSyAxisMin=0.3&IPM2C24A.YPOSyAxisMax=1.3&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=pink&IPM2H01.XPOSyAxisLabel=2H01+X+(mm)&IPM2H01.XPOSyAxisMin=-0.6&IPM2H01.XPOSyAxisMax=0.4&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=darkred&IPM2H01.YPOSyAxisLabel=2H01+Y+(mm)&IPM2H01.YPOSyAxisMin=0.4&IPM2H01.YPOSyAxisMax=1.4&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler= BPM Positions]
 +
 
 +
 
 +
| valign=top |
 +
 
 +
<!--
 +
== Shift Worker Backup Table ==
 +
{| class=wikitable
 +
!width=600 colspan=4 style="background:#ffdead;"| '''Worker Shift Backup'''
 +
|-
 +
| style="background:#ffdead;"|  '''Date''' || style="background:#ffdead;"|  '''Day''' || style="background:#ffdead;"| '''Swing''' || style="background:#ffdead;"| '''Owl'''  
 +
|-
 +
| Fri, Oct 15 ||  John Doe || Jane Doe || Domenico D'Urso
 +
|-
 +
| Sat, Oct 16 ||  Jane Doe || Bob Cat || Alber Einstein
 +
|}
 +
-->
  
'' Log screenshots of:'' (this is for the remote shifter, see dedicated [https://wiki.jlab.org/clas12-run/index.php/Run_Group_M#tab=Remote_Shifts Remote Shifts] tab above.)
+
{| class=wikitable
* Main beamline GUI overview
+
!width=600 colspan=3 style="background:#deffad;"| '''Backup shifter contact info'''
* clas12mon Detector occupancy plots
+
|-
* Trigger rate GUI
+
| style="background:#deffad;"|  '''Name''' || style="background:#deffad;"|  '''Email''' || style="background:#deffad;"| '''Cell phone''' 
 +
|-
 +
| Justin Estee || esteejus@mit.edu ||
 +
|-
 +
| Andrew Denniston || awild@mit.edu ||
 +
|-
 +
| Sara Ratliff || ratliff_sara@gwmail.gwu.edu ||
 +
|-
 +
| Erin Seroka || erinseroka@gwmail.gwu.edu ||
  
'''In case of other questions or uncertainties of what to do, call the RC or PDL'''
+
|}
  
 
|}
 
|}
Line 272: Line 353:
 
===Live Monitoring Links===
 
===Live Monitoring Links===
 
*[https://clas12mon.jlab.org/rgm/pass0_online_qa/tlsummary/ CLAS12 Monitoring Timelines]
 
*[https://clas12mon.jlab.org/rgm/pass0_online_qa/tlsummary/ CLAS12 Monitoring Timelines]
*[https://clasweb.jlab.org/clas12online/timelines/rg-m/RGM2021_progress_charge.html Live Charge Collected Plots]
+
*[https://clasweb.jlab.org/clas12online/timelines/rg-m/RGM2022_progress_charge.html Live Charge Collected Plots]
*[https://clasweb.jlab.org/clas12online/timelines/rg-m/RGM2021_progress.html Live Luminosity Collected Plots]
+
*[https://clasweb.jlab.org/clas12online/timelines/rg-m/RGM2022_progress.html Live Luminosity Collected Plots]
  
  
Line 282: Line 363:
 
{| {{TableStyle1}}
 
{| {{TableStyle1}}
 
| valign=center |
 
| valign=center |
[[File:RGM_monitoring_dec_11_charge.png|1600px]]
+
[[File:RGM_monitoring_dec_21_charge.png|1100px]]
  
  
 
|}
 
|}
  
<!--#######################################  REMOTE SHIFTS  ##############################################-->
 
<!--#######################################  REMOTE SHIFTS  ##############################################-->
 
<!--#######################################  REMOTE SHIFTS  ##############################################-->
 
 
= Remote Shifts =
 
 
{| {{TableStyle1}}
 
 
| valign=top |
 
  
=== Overview ===
 
* Bluejeans for 24-7 communication with counting house:  https://bluejeans.com/950041022
 
* Remote VNC connection instructions:  https://logbooks.jlab.org/entry/3906039
 
** All necessary applications should be avaible from the desktop menu (left/right click on the desktop)
 
* EPICS GUIs should be accessed '''ONLY''' via the desktop menu or by running <tt>clascss-remote</tt>.
 
* [https://userweb.jlab.org/~baltzell/clas12/shift/remote-demo.mp4 Remote Demonstration Video (150 MB)]
 
 
=== Tasks ===
 
* Fill the [https://logbooks.jlab.org/checklists/151 shift checklist]?
 
* Remind the expert in the counting house to close and restart their bluejeans once per shift
 
* Upload plots/screenshots to the [https://logbooks.jlab.org/book/hallb Hall B logbook] once per run WITH BEAM
 
** Beamline overview screen
 
** Trigger rate screen
 
** mon12 Detector occupancy plots
 
* Upload plots/screenshots to the logbook once shift WITH BEAM
 
** RICH temperature map, RICH scalers map
 
* Beam Quality Monitoring
 
** EPICS overview screen
 
*** In VNC or [https://hallbopi.jlab.org/webopi3.3/w?opi=beamline/clas12-web.opi Web Browser]
 
** Strip charts
 
*** In VNC or Web Browser: [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Upstream+and+Midstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scaler_cS3b&pv=scaler_cS4b&pv=scaler_cS6b&pv=scaler_cS12b&pv=scaler_cS13b&pv=scaler_cS14b&pv=scaler_cS15b&scaler_cS3blabel=scaler_cS3b&scaler_cS3bcolor=%23a6cee3&scaler_cS3byAxisLabel=Rate++%28Hz%29&scaler_cS3byAxisMin=&scaler_cS3byAxisMax=&scaler_cS3byAxisLog&scaler_cS3bscaler=&start=2020-08-08+09%3A02%3A36&end=2020-08-08+09%3A07%3A36&scaler_cS4blabel=scaler_cS4b&scaler_cS4bcolor=%231f78b4&scaler_cS4byAxisLabel=&scaler_cS4byAxisMin=&scaler_cS4byAxisMax=&scaler_cS4byAxisLog=&scaler_cS4bscaler=&scaler_cS5byAxisLabel=&scaler_cS5byAxisMin=&scaler_cS5byAxisMax=&scaler_cS5byAxisLog=&scaler_cS5bscaler=&scaler_cS6blabel=scaler_cS6b&scaler_cS6bcolor=%2333a02c&scaler_cS6byAxisLabel=&scaler_cS6byAxisMin=&scaler_cS6byAxisMax=&scaler_cS6byAxisLog=&scaler_cS6bscaler=&scaler_cS7byAxisLabel=&scaler_cS7byAxisMin=&scaler_cS7byAxisMax=&scaler_cS7byAxisLog=&scaler_cS7bscaler=&scaler_cS12blabel=scaler_cS12b&scaler_cS12bcolor=%23e31a1c&scaler_cS12byAxisLabel=&scaler_cS12byAxisMin=&scaler_cS12byAxisMax=&scaler_cS12byAxisLog=&scaler_cS12bscaler=&scaler_cS13blabel=scaler_cS13b&scaler_cS13bcolor=%23fdbf6f&scaler_cS13byAxisLabel=&scaler_cS13byAxisMin=&scaler_cS13byAxisMax=&scaler_cS13byAxisLog=&scaler_cS13bscaler=&scaler_cS14blabel=scaler_cS14b&scaler_cS14bcolor=%23ff7f00&scaler_cS14byAxisLabel=&scaler_cS14byAxisMin=&scaler_cS14byAxisMax=&scaler_cS14byAxisLog=&scaler_cS14bscaler=&scaler_cS15blabel=scaler_cS15b&scaler_cS15bcolor=%23cab2d6&scaler_cS15byAxisLabel=&scaler_cS15byAxisMin=&scaler_cS15byAxisMax=&scaler_cS15byAxisLog=&scaler_cS15bscaler= Upstream/Midstream Halo Counters], [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Downstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scalerS8b&pv=scalerS9b&scalerS8blabel=scalerS8b&scalerS8bcolor=%23a6cee3&scalerS8byAxisLabel=Rate++%28Hz%29&scalerS8byAxisMin=&scalerS8byAxisMax=&scalerS8byAxisLog&scalerS8bscaler=&pv=scalerS10b&pv=scalerS11b&scalerS9blabel=scalerS9b&scalerS9bcolor=%231f78b4&scalerS9byAxisLabel=&scalerS9byAxisMin=&scalerS9byAxisMax=&scalerS9byAxisLog=&scalerS9bscaler=&scalerS10blabel=scalerS10b&scalerS10bcolor=%23b2df8a&scalerS10byAxisLabel=&scalerS10byAxisMin=&scalerS10byAxisMax=&scalerS10byAxisLog=&scalerS10bscaler=&scalerS11blabel=scalerS11b&scalerS11bcolor=%2333a02c&scalerS11byAxisLabel=&scalerS11byAxisMin=&scalerS11byAxisMax=&scalerS11byAxisLog=&scalerS11bscaler= Downstream Halo Counters], [https://epicsweb.jlab.org/wave/?start=2020-07-08+16%3A50%3A02&end=2020-07-08+16%3A55%3A02&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Beam+Currents&fullscreen=false&layoutMode=2&viewerMode=2&pv=IPM2C21A&pv=IPM2C24A&pv=scaler_calc1b&IPM2C21Alabel=IPM2C21A&IPM2C21Acolor=%23a6cee3&IPM2C21AyAxisLabel=Beam+Current+%28nA%29&IPM2C21AyAxisMin=0&IPM2C21AyAxisMax=300&IPM2C21AyAxisLog&IPM2C21Ascaler=&scaler_calc1blabel=Faraday+Cup&scaler_calc1bcolor=%23b2df8a&scaler_calc1byAxisLabel=&scaler_calc1byAxisMin=&scaler_calc1byAxisMax=&scaler_calc1byAxisLog&scaler_calc1bscaler= Beam Currents], [https://epicsweb.jlab.org/wave/?start=2020-08-03+12%3A30%3A57&end=2020-08-03+12%3A35%3A57&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=BPM+Positions+%28Y-Axis+is+mean+%2B%2F-+0.5+mm%29&fullscreen=false&layoutMode=3&viewerMode=2&pv=IPM2C24A.XPOS&pv=IPM2C24A.YPOS&pv=IPM2H01.XPOS&pv=IPM2H01.YPOS&IPM2C24A.XPOSlabel=IPM2C24A.XPOS&IPM2C24A.XPOScolor=%23e31a1c&IPM2C24A.XPOSyAxisLabel=&IPM2C24A.XPOSyAxisMin=-2.0&IPM2C24A.XPOSyAxisMax=+1.0&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=pink&IPM2C24A.YPOSyAxisLabel=&IPM2C24A.YPOSyAxisMin=-2.0&IPM2C24A.YPOSyAxisMax=1.0&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=darkgreen&IPM2H01.XPOSyAxisLabel=&IPM2H01.XPOSyAxisMin=-2.0&IPM2H01.XPOSyAxisMax=1.0&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=lightgreen&IPM2H01.YPOSyAxisLabel=&IPM2H01.YPOSyAxisMin=-2.0&IPM2H01.YPOSyAxisMax=1.0&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler=#a6cee3&IPM2C24A.XPOSyAxisLabel=2C24+X+(mm)&IPM2C24A.XPOSyAxisMin=-1.5&IPM2C24A.XPOSyAxisMax=-0.5&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=%231f78b4&IPM2C24A.YPOSyAxisLabel=2C24+Y+(mm)&IPM2C24A.YPOSyAxisMin=0.3&IPM2C24A.YPOSyAxisMax=1.3&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=pink&IPM2H01.XPOSyAxisLabel=2H01+X+(mm)&IPM2H01.XPOSyAxisMin=-0.6&IPM2H01.XPOSyAxisMax=0.4&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=darkred&IPM2H01.YPOSyAxisLabel=2H01+Y+(mm)&IPM2H01.YPOSyAxisMin=0.4&IPM2H01.YPOSyAxisMax=1.4&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler= BPM Positions]
 
* Data Quality Monitoring
 
** mon12
 
*** [https://clas12mon.jlab.org/mon12/histograms/?reference=3954936 Reference, current, and 5 most recent runs] '''Update the reference number!'''
 
* Alarms
 
** If responding to RICH or Trigger alarms please post screens also to RICH or HBTRIGGER logbook, respectively
 
 
 
| valign=top |
 
 
== Shift Worker Backup Table ==
 
{| class=wikitable
 
!width=600 colspan=4 style="background:#ffdead;"| '''Worker Shift Backup'''
 
|-
 
| style="background:#ffdead;"|  '''Date''' || style="background:#ffdead;"|  '''Day''' || style="background:#ffdead;"| '''Swing''' || style="background:#ffdead;"| '''Owl'''
 
|-
 
| Fri, Oct 15 ||  John Doe || Jane Doe || Domenico D'Urso
 
|-
 
| Sat, Oct 16 ||  Jane Doe || Bob Cat || Alber Einstein
 
|}
 
 
{| class=wikitable
 
!width=600 colspan=3 style="background:#deffad;"| '''Backup shifter contact info'''
 
|-
 
| style="background:#deffad;"|  '''Name''' || style="background:#deffad;"|  '''Email''' || style="background:#deffad;"| '''Cell phone''' 
 
|-
 
| Justin Estee || esteejus@mit.edu || 517 896 5905
 
|-
 
| Andrew Denniston || awild@mit.edu || + 987654321
 
|-
 
| Sara Ratliff || ratliff_sara@gwmail.gwu.edu || 774 266 6758
 
|-
 
| Erin Seroka || erinseroka@gwmail.gwu.edu> || + 987654321
 
 
|}
 
 
|}
 
  
 
= Useful Links =
 
= Useful Links =
Line 385: Line 400:
 
| valign=top |
 
| valign=top |
  
===BlueJeans meetings===
+
===ZOOM meetings===
  
 
* 07:45 [https://jlab-org.zoomgov.com/j/1611843361?pwd=YU55WVVwVS9ZVDEvT1I5M1VIbnJyQT09 RC/PD Morning Meeting]
 
* 07:45 [https://jlab-org.zoomgov.com/j/1611843361?pwd=YU55WVVwVS9ZVDEvT1I5M1VIbnJyQT09 RC/PD Morning Meeting]
 
* 08:00 [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 MCC/OPS Morning Meeting]
 
* 08:00 [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 MCC/OPS Morning Meeting]
 
*15:30 Daily RC Meeting  
 
*15:30 Daily RC Meeting  
** [https://jlab.bluejeans.com/759437905/8110 BlueJean Link]
+
** [https://jlab-org.zoomgov.com/j/1612697153?pwd=d3ZRdWgxMEJoTlZmWC9GTFZxb2dUZz09 Zoom Link]
** Meeting ID: 759437905
+
** Meeting ID: 161 269 7153
** Passcode: 8110
+
** Passcode: 474207
** On site - CEBAF Center F324-325 conference room
 
 
** Daily Analysis Meeting to follow directly after
 
** Daily Analysis Meeting to follow directly after
 
** [[RGM_RC_Meetings | Meeting Agendas]]
 
** [[RGM_RC_Meetings | Meeting Agendas]]

Latest revision as of 13:53, 25 July 2024

[edit]

If calling local numbers (with area code prefix 757) from the counting room dial 9+[last 7 digits]. To call other area codes dial 91+[ten digit number]

Role Phone Number
Hall B Run Coordinator (757) 575-7540 (cell)
Hall B Physics Division Liaison (757) 876-1789 (cell)
MCC 7048
Crew Chief 7045
Crew Chief (757) 876-3367 (cell)
Program Deputy (757) 876-7997 (cell)
RadCon (757) 876-1743 (cell)
Gate House Guard 5822
Location Phone Number
Hall B Floor 5165
Hall B Space Frame 5170 and 5171
Hall B Forward Carriage 5371
Hall B Gas Shed 7115
Hall B Counting House 5244 (Shift Expert)
Hall B Counting House (757) 329-4846 (Shift Expert cell)
Hall B Counting House 5245 or 5126 (Shift Worker)
Hall A Counting House 5501
Hall C Counting House 6000
Hall D Counting House 5504
Hall B System Phone Number On-Call Person
Engineering (757) 748-5048 (cell)
(757) 897-9060 (cell)
Engineering On-Call (primary)
Denny Insley (secondary)
Slow Controls (757) 748-6922 (cell) Nathan Baltzell
Beamline (757) 303-3996 (cell) Eugene Pasyuk
DC (757) 218-4372 (cell)
(757) 748-5048 (cell)
Florian Hauenstein (primary)
Engineering On-Call (secondary)
SVT/MVT/MM (757) 541-7539 (cell)
(757) 753-7769 (cell)
Yuri Gotra (primary)
Rafo Paremuzyan (secondary)
ECAL (757) 810-1489 (cell) Cole Smith
FTOF/CTOF/CND (757) 344-7204 (cell) Daniel Carman
ALERT (757) 329-4844 (cell) Raphael Dupré
HTCC/LTCC (757) 344-7174 (cell) Youri Sharabian
FT (757) 344-1848 (cell) Raffaella De Vita
BAND (757) 310-7198 (cell) Florian Hauenstein
RICH (757) 344-3235 (cell)
(757) 748-6922 (cell)
Christopher Dilks (primary)
Nathan Baltzell (secondary)
DAQ (757) 232-6221 (cell) Sergey Boiarinov
HYDRA (317) 550-9226 (cell) Torri Jeske
Authorized Hall B Solenoid/Torus Operators
Hall B Denny Insley, Morgan Cook, Eugene Pasyuk
Magnet Group Probir Ghosha, Renuka Rajput-Ghoshal
Detector Support Group Brian Eng, Pablo Campero, Tyler Lemon
DC Power Onish Kumar, Sarin Philip
  • Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
  • To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
  • Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.

Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.


CLAS12 Run Group M, Fall 2021

Beam energies: 2.1, 4.0, 6.0 GeV (1.96 GeV/pass)

RC: Susan Schadmand

PDL: Valery Kubarovsky

Run Plan: Friday, Feb 7-8, 2022

Production runs use PROD67_noVTPread and the trigger rgm_6GeV_inb_v1_0.trg .
Run duration 100M events or 4 hours, whichever comes first.

  • run 6GeV 80 nA on Ca48 target (240 mg/cm2), beam blocker IN, until SAD
  • low luminosity runs:(ca 3pm - 9pm on Feb 7)
    • 2 hrs 5nA
    • 2 hrs 10 nA
    • 2 hrs 40 nA
  • the run on Ca48 until 6am, Feb 8
  • RC will be there at 6 am and follow Eugene's instruction
    • put the blank collimator in
    • turn HV off for all tracking detectors, just in case if the tagger magnet trips during the test
    • MCC may mask upstream halo FSD if necessary but keep all other FSD unmasked

DAQ configuration

PROD67_noVTPread , production trigger rgm_6GeV_inb_v1_0.trg .

NOTE: UNLESS a RICH problem crashes the DAQ, do NOT interrupt an otherwise smooth run to do a RICH recovery - instead do this in between runs.

NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms at least once every 30-60 minutes to make sure there are no major detector problems.

At the end of each run, follow the STANDARD DAQ RESTART SEQUENCE

  • "end run", if the run ended correctly then: "prestart", "go"

  • if the run did not end correctly or if any ROCs had to be rebooted:
  • "cancel", "reset"
    • "configure", "download", "prestart", "go"
  • After each step, make sure it is completed in the Run Control message window. If a ROC has crashed, find which one it is, issue a roc_reboot command ON JUST THAT ROC and try again. Contact the DAQ expert if there are any questions.

References and Standards

(last update 01/18/2022- 23:30)

Nominal Beam Positions

  • 2H01, X: -0.6 mm, Y: 0.8 mm
  • 2C24, X: -2.0 mm, Y: +0.6 mm

FSD Thresholds

  • Upstream: 2000 Hz
  • Midstream: 2000 Hz
  • Downstream: 500000 Hz
  • BOM: 10000
  • 5 ms dwell time

Reference Harp Scans for Beam on Faraday Cup: 2H01 [1]

Reference Harp Scans for Beam on Tagger dump: 2C21 [2], tagger harp [3]

Reference Monitoring Histograms:

Counter rates

  • Upstream counters integrated rates: 0-15 Hz (acceptable up to 100 Hz are acceptable) @50 nA.
  • Midstream counters: 10-20 Hz (acceptable up to 50 Hz) @50 nA.
  • Counting rates of ~ hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.

Beamline vacuum: should be not higher than 5e-5.

NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms (mon12) at least once every 30-60 minutes to make sure there are no major detector problems.

Notes

  1. LTCC is NOT used in this experiment. HV should be kept OFF.
  2. FMT only using 3 FMT layers, not 6.
  3. The main lights in the Hall (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during access, they should be switched off when leaving the Hall. Refer to these photos:
    • ON: [4]
    • OFF: [5]
    • Note that the dome lights when switched off cannot be turned back on immediately because they require 10-15 min to cool down.
  4. In case of a Torus and/or Solenoid Fast Dump do the following:
    • Notify MCC to request beam OFF and to drop Hall B status to Power Permit
    • Call Engineering on-call
    • Make a separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Probir Goshal, Dave Kashy, and esr-users@jlab.org
    • Notify Run Coordinator
    • Turn off all detectors
  5. Observe the guidance of the alarm handler.


Known Issues

  • Beamline overview No Data from Faraday cup viewer camera, network switch died
  • DAQ when starting a run, the live time alarm goes off, while status of the ROCs all ok, then the alarm can just be acknowledged
  • DAQ The error messages " ERR: event# ..." e.g. for crates tdcband1, tdcecal1 and tdcecal6 are NOT a problem. Can go along with relatively higher roc rates.
  • RICH recovery only between runs. also when you see problems like a missing tile
  • RICH FPGA temperatures can show yellow tiles. Yellow tiles in the RICH temperature map are normal. It is done just to pay attention to the tiles with temp>70 degrees. The alarm is set to 75 degrees https://logbooks.jlab.org/entry/3975547

NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms at least once every 30 - 60 minutes to make sure there are no major detector problems.

  • Follow the [Short Term Schedule] as outlined by RC
    • includes Run Plan, DAQ configuration, and References and Standards
  • Keep shift summary up to date in HBLOG. Record all that happens.
  • Cycle the FMT gas once per shift, in-between runs. Pease log in shift summary.
    • If it is not reset, the interlock may drop and disable the HV.
    • Turning off and on the gas flow without pausing to avoid HV trips.
    • If the HV tripped, make sure that once gas flow is restarted and the flow differential is down to reasonable values, to turn the FMT HV back on and let it ramp all the way up.
    • Remember that this experiment is only using 3 FMT layers, not 6.
  • Do a RICH recovery (press the RICH Recovery button on the GUI) once daily during day shift, between runs. Please log in shift summary.
    • Note the automated "RICH Recovery" sequence already confirms RICH4 is up and accepting ssh connections before claiming success. And it also prints out that you have to "Cancel->Reset->Configure->Download->Prestart" before starting the next run.
  • Fill out BTA hourly. Click "Load from EPICS" to automatically fill the left side then correct as needed.
    • Accelerator beam time:
      • ABU: acceptable beam used (eg harp scans, calibrations, trigger settings, running)
      • BANU: beam acceptable but not used (eg radiator change or our problems)
      • BNA: beam not acceptable (eg tuning, drifting, not focused)
    • Experiment beam time
      • ER: experiment ready
      • PCC: planned configuration change (when beam is masked while radiators are moved, DAQ (roc rebooting, restarting runs)), if more than 5 minutes, put a short comment, eg harp scans or DAQ.
      • UED: unplanned experiment down (hardware failure)


In case of other questions or uncertainties of what to do, call the RC or PDL

(remote) shift worker: see dedicated Remote Shifts tab above.



Tasks

Every Run:

  • WITH BEAM, log screen shots of
    • Beamline Overview, in VNC or Web Browser
    • CLAS12 Trigger rates and DAQ status

Every Shift:

  • Log screen shots of RICH temperature and scaler maps. Log in HBLOG and RICH logbook.

Regularly:

  • reset & check spectra frequently (every 30 - 60 minutes)
    • Some plots in mon12 have a choice of histogram sets per sector, select buttons at the bottom of the plot. Only the currently selected set ends up in the logbook entry.
    • that means you have to look at all sectors for these histograms
  • Log the strip charts in time intervals according to the x-axis time span, using the liveplot configuration Beamline4Logbook, see https://logbooks.jlab.org/entry/3978837 .
    • in VNC: use CS-Studio, Tools, Strip Charts, livePlot
      • right-click on the livePlot screen and select "Load a Configuration"
      • the configuration "Beamline4Logbook" provides the beam current and position information
      • right-click on the screen and select "Make Elog Entry", make sure to log to HBLOG and not ELOG



Backup shifter contact info
Name Email Cell phone
Justin Estee esteejus@mit.edu
Andrew Denniston awild@mit.edu
Sara Ratliff ratliff_sara@gwmail.gwu.edu
Erin Seroka erinseroka@gwmail.gwu.edu

Webcams

Manuals

Hall Webcams

Epics on the web


Live Monitoring Links



RGM monitoring dec 21 charge.png




Clas12design.png