Difference between revisions of "Run Group M"
(39 intermediate revisions by one other user not shown) | |||
Line 6: | Line 6: | ||
<!--==={{#switchtablink:Phone Numbers|'''Phone Numbers'''}}===--> | <!--==={{#switchtablink:Phone Numbers|'''Phone Numbers'''}}===--> | ||
===[http://www.jlab.org/Hall-B/shifts Shift Schedule]=== | ===[http://www.jlab.org/Hall-B/shifts Shift Schedule]=== | ||
− | ===[https:// | + | ===[https://logbooks.jlab.org/book/hallb Hall B Logbook]=== |
===[https://logbooks.jlab.org/checklists/151 Shift Checklist] === | ===[https://logbooks.jlab.org/checklists/151 Shift Checklist] === | ||
===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]=== | ===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]=== | ||
Line 12: | Line 12: | ||
* See guidance at '''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf BTA User Guide]'''. | * See guidance at '''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf BTA User Guide]'''. | ||
<!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation] === --> | <!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation] === --> | ||
+ | ===[https://www.jlab.org/Hall-B/run-web/rgm/ESAD_HallB-CLAS12_rgM.pdf ESAD], [https://www.jlab.org/Hall-B/run-web/rgm/COO_HallB-CLAS12_RGM.pdf COO], [https://www.jlab.org/Hall-B/run-web/rgm/RSAD_HallB-CLAS12_rgM.pdf RSAD], [https://www.jlab.org/div_dept/train/SAF111/Hall%20B%20worker%20Safety%20Training%20%28SAF111%29%20%2008%2001-12-1.pdf ERG] === | ||
| valign=top | | | valign=top | | ||
Line 73: | Line 74: | ||
''' Beam energies: 2.1, 4.0, 6.0 GeV (1.96 GeV/pass) '''<br> | ''' Beam energies: 2.1, 4.0, 6.0 GeV (1.96 GeV/pass) '''<br> | ||
− | === RC: Susan Schadmand | + | === RC: Susan Schadmand === |
− | * | + | * (757) 575-7540, [mailto:susansch@jlab.org susansch@jlab.org] |
− | |||
* 9 575 7540 from Counting Room | * 9 575 7540 from Counting Room | ||
Line 83: | Line 83: | ||
* [mailto:vpk@jlab.org vpk@jlab.org] | * [mailto:vpk@jlab.org vpk@jlab.org] | ||
− | == <font color=blue>''' Run Plan: Feb | + | == <font color=blue>''' Run Plan: Friday, Feb 7-8, 2022 '''</font> == |
Production runs use <b> PROD67_noVTPread </b> and the trigger <b> rgm_6GeV_inb_v1_0.trg </b>.<br/> | Production runs use <b> PROD67_noVTPread </b> and the trigger <b> rgm_6GeV_inb_v1_0.trg </b>.<br/> | ||
Run duration 100M events or 4 hours, whichever comes first. | Run duration 100M events or 4 hours, whichever comes first. | ||
− | * | + | * run 6GeV 80 nA on Ca48 target (240 mg/cm2), beam blocker IN, until SAD |
− | |||
− | * | + | * low luminosity runs:(ca 3pm - 9pm on Feb 7) |
− | * | + | ** 2 hrs 5nA |
+ | ** 2 hrs 10 nA | ||
+ | ** 2 hrs 40 nA | ||
− | * | + | * the run on Ca48 until 6am, Feb 8 |
− | |||
− | * | + | * 6am Feb 8: Investigate BLA tune beam trips with tune beam to Hall B, https://devweb.acc.jlab.org/CSUEApps/atlis/task/24015 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | * RC will be there at 6 am and follow Eugene's instruction | ||
+ | ** put the blank collimator in | ||
+ | ** turn HV off for all tracking detectors, just in case if the tagger magnet trips during the test | ||
+ | ** MCC may mask upstream halo FSD if necessary but keep all other FSD unmasked | ||
== <font color=blue> DAQ configuration </font> == | == <font color=blue> DAQ configuration </font> == | ||
Line 144: | Line 141: | ||
<b> Reference Harp Scans for Beam on Tagger dump: </b> 2C21 [https://logbooks.jlab.org/entry/3963244], tagger harp [https://logbooks.jlab.org/entry/3963250] | <b> Reference Harp Scans for Beam on Tagger dump: </b> 2C21 [https://logbooks.jlab.org/entry/3963244], tagger harp [https://logbooks.jlab.org/entry/3963250] | ||
− | <b> Reference Monitoring Histograms | + | <b> Reference Monitoring Histograms:</b> |
− | + | * [https://logbooks.jlab.org/entry/3982817 6 GeV 80 nA on Ca48] | |
+ | * [https://logbooks.jlab.org/entry/3980929 6 GeV 90 nA on Sn] | ||
+ | * [https://logbooks.jlab.org/entry/3973807 6 nA, production C] | ||
+ | * [https://logbooks.jlab.org/entry/3943458 50 nA, production LD2] | ||
<b> Counter rates </b> | <b> Counter rates </b> | ||
Line 179: | Line 179: | ||
== <font color=blue> Known Issues </font> == | == <font color=blue> Known Issues </font> == | ||
− | * ''' | + | * '''Beamline overview''' No Data from Faraday cup viewer camera, network switch died |
− | * '''DAQ''' the | + | |
− | + | * '''DAQ''' when starting a run, the live time alarm goes off, while status of the ROCs all ok, then the alarm can just be acknowledged | |
− | * '''DAQ''' The error messages " ERR: event# ..." e.g. for crates tdcband1, tdcecal1 and tdcecal6 are NOT a problem | + | * '''DAQ''' The error messages " ERR: event# ..." e.g. for crates tdcband1, tdcecal1 and tdcecal6 are NOT a problem. Can go along with relatively higher roc rates. |
* '''PCAL''' transient: mu strip occupancy hole in U view TDC, https://logbooks.jlab.org/entry/3978499, https://logbooks.jlab.org/entry/3978736 | * '''PCAL''' transient: mu strip occupancy hole in U view TDC, https://logbooks.jlab.org/entry/3978499, https://logbooks.jlab.org/entry/3978736 | ||
Line 188: | Line 188: | ||
* '''ECAL''' HV SEC2_WI_E36 is known to be problematic. Channel stays off for now. | * '''ECAL''' HV SEC2_WI_E36 is known to be problematic. Channel stays off for now. | ||
− | * '''BMT''' off: occupancy Z, layer 3, sector 1, detetcor 7, S1L3 strip HV is off due to high leakage, https://logbooks.jlab.org/entry/3970886 | + | * '''BMT''' off: histogram occupancy Z, layer 3, sector 1, detetcor 7, S1L3 strip HV is off due to high leakage, https://logbooks.jlab.org/entry/3970886 |
− | * '''BMT''' off: occupancy Z, layer 5, sector 2, detetcor 14 | + | * '''BMT''' off: histogram occupancy Z, layer 5, sector 2, detetcor 14 |
+ | * '''BMT''' SEC1 L1 STRIP: reduced HV. (This tile will have almost 0 efficiency), https://logbooks.jlab.org/entry/3982425 | ||
− | * '''RICH''' when a tile | + | * '''RICH''' recovery only between runs. also when you see problems like a missing tile |
* '''RICH''' FPGA temperatures can show yellow tiles. Yellow tiles in the RICH temperature map are normal. It is done just to pay attention to the tiles with temp>70 degrees. The alarm is set to 75 degrees https://logbooks.jlab.org/entry/3975547 | * '''RICH''' FPGA temperatures can show yellow tiles. Yellow tiles in the RICH temperature map are normal. It is done just to pay attention to the tiles with temp>70 degrees. The alarm is set to 75 degrees https://logbooks.jlab.org/entry/3975547 | ||
Line 258: | Line 259: | ||
* upload monitoring plots (mon12) to logook | * upload monitoring plots (mon12) to logook | ||
− | ** Reference, current, and 5 most recent runs, choose a reference run | + | ** '''look at the spectra''': Reference, current, and 5 most recent runs, choose a reference run (the reference numbers refer to logbook entries): |
+ | *** 6 GeV 80 nA on Ca48 [https://clas12mon.jlab.org/mon12/histograms/?reference=3982817 https://clas12mon.jlab.org/mon12/histograms/?reference=3982817] | ||
+ | *** 6 GeV 90 nA on Sn [https://clas12mon.jlab.org/mon12/histograms/?reference=3980929 https://clas12mon.jlab.org/mon12/histograms/?reference=3980929] | ||
*** ref 6 nA, production C, [https://clas12mon.jlab.org/mon12/histograms/?reference=3973807 https://clas12mon.jlab.org/mon12/histograms/?reference=3973807] | *** ref 6 nA, production C, [https://clas12mon.jlab.org/mon12/histograms/?reference=3973807 https://clas12mon.jlab.org/mon12/histograms/?reference=3973807] | ||
*** ref 50 nA, production LD2, [https://clas12mon.jlab.org/mon12/histograms/?reference=3943458 https://clas12mon.jlab.org/mon12/histograms/?reference=3943458] | *** ref 50 nA, production LD2, [https://clas12mon.jlab.org/mon12/histograms/?reference=3943458 https://clas12mon.jlab.org/mon12/histograms/?reference=3943458] | ||
Line 266: | Line 269: | ||
* Fill the [https://logbooks.jlab.org/checklists/151 shift checklist] | * Fill the [https://logbooks.jlab.org/checklists/151 shift checklist] | ||
− | * Log screen shots of RICH temperature and scaler maps | + | * Log screen shots of RICH temperature and scaler maps. Log in HBLOG and RICH logbook. |
'''Regularly''': | '''Regularly''': |
Latest revision as of 13:53, 25 July 2024
- Shift Documentation
- Phone Numbers
- Short Term Schedule
- Notes/Known Issues
- Shift Expert
- Remote Worker Shift
- Monitoring
- Useful Links
Shift ScheduleHall B LogbookShift ChecklistHot CheckoutBeam Time Accounting
ESAD, COO, RSAD, ERG |
Manuals |
Procedures |
JLab Logbooks
|
If calling local numbers (with area code prefix 757) from the counting room dial 9+[last 7 digits]. To call other area codes dial 91+[ten digit number]
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
CLAS12 Run Group M, Fall 2021
Beam energies: 2.1, 4.0, 6.0 GeV (1.96 GeV/pass)
RC: Susan Schadmand
- (757) 575-7540, susansch@jlab.org
- 9 575 7540 from Counting Room
PDL: Valery Kubarovsky
- (757) 876-1789
- 9 876-1789 from Counting Room
- vpk@jlab.org
Run Plan: Friday, Feb 7-8, 2022
Production runs use PROD67_noVTPread and the trigger rgm_6GeV_inb_v1_0.trg .
Run duration 100M events or 4 hours, whichever comes first.
- run 6GeV 80 nA on Ca48 target (240 mg/cm2), beam blocker IN, until SAD
- low luminosity runs:(ca 3pm - 9pm on Feb 7)
- 2 hrs 5nA
- 2 hrs 10 nA
- 2 hrs 40 nA
- the run on Ca48 until 6am, Feb 8
- 6am Feb 8: Investigate BLA tune beam trips with tune beam to Hall B, https://devweb.acc.jlab.org/CSUEApps/atlis/task/24015
- RC will be there at 6 am and follow Eugene's instruction
- put the blank collimator in
- turn HV off for all tracking detectors, just in case if the tagger magnet trips during the test
- MCC may mask upstream halo FSD if necessary but keep all other FSD unmasked
DAQ configuration
PROD67_noVTPread , production trigger rgm_6GeV_inb_v1_0.trg .
NOTE: UNLESS a RICH problem crashes the DAQ, do NOT interrupt an otherwise smooth run to do a RICH recovery - instead do this in between runs.
NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms at least once every 30-60 minutes to make sure there are no major detector problems.
At the end of each run, follow the STANDARD DAQ RESTART SEQUENCE
- "end run", if the run ended correctly then: "prestart", "go"
- if the run did not end correctly or if any ROCs had to be rebooted:
- "cancel", "reset"
- "configure", "download", "prestart", "go"
- After each step, make sure it is completed in the Run Control message window. If a ROC has crashed, find which one it is, issue a roc_reboot command ON JUST THAT ROC and try again. Contact the DAQ expert if there are any questions.
References and Standards
(last update 01/18/2022- 23:30)
Nominal Beam Positions
- 2H01, X: -0.6 mm, Y: 0.8 mm
- 2C24, X: -2.0 mm, Y: +0.6 mm
FSD Thresholds
- Upstream: 2000 Hz
- Midstream: 2000 Hz
- Downstream: 500000 Hz
- BOM: 10000
- 5 ms dwell time
Reference Harp Scans for Beam on Faraday Cup: 2H01 [1]
Reference Harp Scans for Beam on Tagger dump: 2C21 [2], tagger harp [3]
Reference Monitoring Histograms:
Counter rates
- Upstream counters integrated rates: 0-15 Hz (acceptable up to 100 Hz are acceptable) @50 nA.
- Midstream counters: 10-20 Hz (acceptable up to 50 Hz) @50 nA.
- Counting rates of ~ hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.
Beamline vacuum: should be not higher than 5e-5.
NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms (mon12) at least once every 30-60 minutes to make sure there are no major detector problems.
Notes
- LTCC is NOT used in this experiment. HV should be kept OFF.
- FMT only using 3 FMT layers, not 6.
- The main lights in the Hall (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during access, they should be switched off when leaving the Hall. Refer to these photos:
- In case of a Torus and/or Solenoid Fast Dump do the following:
- Notify MCC to request beam OFF and to drop Hall B status to Power Permit
- Call Engineering on-call
- Make a separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Probir Goshal, Dave Kashy, and esr-users@jlab.org
- Notify Run Coordinator
- Turn off all detectors
- Observe the guidance of the alarm handler.
Known Issues
- Beamline overview No Data from Faraday cup viewer camera, network switch died
- DAQ when starting a run, the live time alarm goes off, while status of the ROCs all ok, then the alarm can just be acknowledged
- DAQ The error messages " ERR: event# ..." e.g. for crates tdcband1, tdcecal1 and tdcecal6 are NOT a problem. Can go along with relatively higher roc rates.
- PCAL transient: mu strip occupancy hole in U view TDC, https://logbooks.jlab.org/entry/3978499, https://logbooks.jlab.org/entry/3978736
- ECAL one strip of TDC ECout W strip sector4 is hot, https://logbooks.jlab.org/entry/3979286
- ECAL HV SEC2_WI_E36 is known to be problematic. Channel stays off for now.
- BMT off: histogram occupancy Z, layer 3, sector 1, detetcor 7, S1L3 strip HV is off due to high leakage, https://logbooks.jlab.org/entry/3970886
- BMT off: histogram occupancy Z, layer 5, sector 2, detetcor 14
- BMT SEC1 L1 STRIP: reduced HV. (This tile will have almost 0 efficiency), https://logbooks.jlab.org/entry/3982425
- RICH recovery only between runs. also when you see problems like a missing tile
- RICH FPGA temperatures can show yellow tiles. Yellow tiles in the RICH temperature map are normal. It is done just to pay attention to the tiles with temp>70 degrees. The alarm is set to 75 degrees https://logbooks.jlab.org/entry/3975547
NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms at least once every 30 - 60 minutes to make sure there are no major detector problems.
(remote) shift worker: see dedicated Remote Shifts tab above. |
TasksEvery Run:
Every Shift:
Regularly:
|
|
Webcams
|
Manuals |
Hall Webcams |
Epics on the web
|
Live Monitoring Links
|
|
Hall-B
Run lists |
AcceleratorReferences |
ZOOM meetings
|