− | == '''Run Plan for | + | == '''Run Plan for Friday April 6 Owl and day shift:''' == |
− | * Continue to take production data with <b> | + | * Continue to take production data with <b>trigger_6gev_elas.trg</b> at 5nA with solenoid at half field |
* Stop the run if it reached 100M events or 3 hours duration. | * Stop the run if it reached 100M events or 3 hours duration. | ||
* <b>Note to shift leader:</b> please include relevant links for runs/events to your logbook summary, like here: https://logbooks.jlab.org/entry/3553286 | * <b>Note to shift leader:</b> please include relevant links for runs/events to your logbook summary, like here: https://logbooks.jlab.org/entry/3553286 | ||
− | * If the machine is down and it is back start with low current first (2nA | + | * If the machine is down and it is back start with low current first (2nA) making sure that the beam is stable in current and position before moving to 5 nA. If the beam position or rates have changed call RC. |
+ | |||
+ | * At 7:30 AM RC/PDL will ramp down the solenoid to Zero field and empty the target | ||
+ | * We will take short run with zero field and empty target (RC, PDL and SVT expert will be present | ||
+ | * After that we will stop beam for pass change from 3 pass to 5 pass | ||
+ | * PDL/RC Ramp the Solenoid to full filed | ||
+ | * Prepare for beam tunning following the procedure outlined in establishing beam procedure document | ||
+ | * One MCC ready to deliver beam ask MCC for 5 nA and follow the procedure outlined in esablishing beam document for beam tuning to the tagger | ||
+ | |||
+ | |||
Revision as of 01:23, 6 April 2018
[edit]
Shift ScheduleShift ChecklistHot CheckoutBeam Time Accounting
|
Manuals |
Procedures |
JLab Logbooks
|
If calling local numbers (with area code prefix 757) from the counting room dial 9+[last 7 digits]. To call other area codes dial 91+[10 digit number]
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 Run Group A, Spring 2018
Beam energy 10.6 GeV (5 pass)
Important: Document all your work in the logbook!
Remember to fill in the run list at the beginning and end of each run (clas12run@gmail.com can fill the run list)
RC: Latifa Elouadrhiri
- (757) 575-7540
- 9 575 7540 from Counting Room
- latifa@jlab.org
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
- pasyuk@jlab.org
- Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.
- Note 2: At the end of each run, follow the DAQ restart sequence "end run", "abort", "reset", "download", "prestart", "go". After DAQ prestart is complete reboot the scaler IOCs with the command: iocjscalerRestartAll.sh. Note: After each step, make sure it is complete in the Run Control message window. If a roc has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
- Note 3: Nominal beam positions: 2H01 (X=1.0 mm, Y=-1.5 mm)
- Note 4: With beam to the Faraday Cup, typical rates on all halo counters upstream from the target should be either 0 or of the order of few counts. Count rates in the range of tens or more may indicate bad beam tune or bleed-through from other Halls.
Run Plan:(last update 4/04- 19:00)
Run Plan for Friday April 6 Owl and day shift:
In case of other questions or uncertainties of what to do, please call the RC
|
General Instructions:
Every Shift:
Every Run: Log screenshots of:
|