Difference between revisions of "Engineering Run"
Jump to navigation
Jump to search
Line 89: | Line 89: | ||
* Whenever preparing to receive beam, make sure the following conditions are established: all CLAS12 detectors are off and target is empty. For SVT, MVT, FTH and FTT, turn first HV off and then LV off. For any problem, consult with the expert-on-call. | * Whenever preparing to receive beam, make sure the following conditions are established: all CLAS12 detectors are off and target is empty. For SVT, MVT, FTH and FTT, turn first HV off and then LV off. For any problem, consult with the expert-on-call. | ||
* Continue the beamline commissioning following the instructions described in [https://wiki.jlab.org/clas12-run/images/7/74/CLAS12_beamline_commissioning.pdf]: | * Continue the beamline commissioning following the instructions described in [https://wiki.jlab.org/clas12-run/images/7/74/CLAS12_beamline_commissioning.pdf]: | ||
− | ** establish beam to the faraday cup: beam current should be 1.5 nA, positions, quads settings and rates should be as in ; | + | ** establish beam to the faraday cup: beam current should be 1.5 nA, positions, quads settings and rates should be as in https://logbooks.jlab.org/entry/3502318; |
** make sure beam is stable and beam spot is clearly visible on the chromax viewer; | ** make sure beam is stable and beam spot is clearly visible on the chromax viewer; | ||
** with the support of the beamline expert, set FSD thresholds to trigger the beam shutdown in case rates become too high; | ** with the support of the beamline expert, set FSD thresholds to trigger the beam shutdown in case rates become too high; |
Revision as of 00:48, 11 December 2017
[edit]
Shift ScheduleShift ChecklistHot CheckoutBeam Time Accounting |
Manuals |
Procedures |
JLab Logbooks
|
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 Engineering Run, Fall 2017
Beam energy 10.6 GeV (5 pass)
Important: Document all your work in the logbook!
RC: Raffaella DeVita
- (757) 575-7540
- 9 575 7540 from Counting Room
- devita@jlab.org
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
- pasyuk@jlab.org
Run Plan: beamline commissioning
Important Notes:
|
General Instructions:Locking up the hall
|
Every Shift:
|
Every Run:
|
---|
Webcams |
Manuals |
Epics on the web
|