Difference between revisions of "Engineering Run"
Jump to navigation
Jump to search
Line 112: | Line 112: | ||
* At 100% solenoid field take 30 of data at the highest current authorized by the SVT/MM folks (ensuring that the DC and other detector currents/rates are acceptable). Select the trigger file based on high threshold ECAL clusters (to select electrons). Contact the DAQ expert to set this up. | * At 100% solenoid field take 30 of data at the highest current authorized by the SVT/MM folks (ensuring that the DC and other detector currents/rates are acceptable). Select the trigger file based on high threshold ECAL clusters (to select electrons). Contact the DAQ expert to set this up. | ||
* Fill the target. Contact Engineering on-call to complete this work. | * Fill the target. Contact Engineering on-call to complete this work. | ||
− | * Restore beam to the Faraday cup at 0.5 nA. Record rates in all detectors, and currents in the DC, SVT, and MM, at beam currents of 0.5 nA, 5 nA, 10 nA, 15 nA, ... The | + | * Restore beam to the Faraday cup at 0.5 nA. Record rates in all detectors, and currents in the DC, SVT, and MM, at beam currents of 0.5 nA, 5 nA, 10 nA, 15 nA, ... The beam intensity and duration will be established by the beamline expert, the SVT and MM experts, the DC experts, and the Forward Carriage experts. |
− | beam intensity and duration will be established by the beamline expert, the SVT and MM experts, the DC experts, and the Forward Carriage experts. | ||
* Allocate several hours to work on detector optimization. This includes: | * Allocate several hours to work on detector optimization. This includes: | ||
** Reduce the DC time windows closer to their nominal production values | ** Reduce the DC time windows closer to their nominal production values |
Revision as of 14:00, 14 December 2017
[edit]
Shift ScheduleShift ChecklistHot CheckoutBeam Time Accounting |
Manuals |
Procedures |
JLab Logbooks
|
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 Engineering Run, Fall 2017
Beam energy 10.6 GeV (5 pass)
Torus : +3770 A (100% field); Solenoid : +1208 A (50% field)
Important: Document all your work in the logbook!
RC: Daniel S. Carman
- (757) 575-7540
- 9 575 7540 from Counting Room
- carman@jlab.org
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
- pasyuk@jlab.org
Run Plan:
|
General Instructions:
Beam Tuning:
|
Every Shift:
|