Difference between revisions of "Run Group C"
Line 279: | Line 279: | ||
** CLAS12 Trigger rates and DAQ status | ** CLAS12 Trigger rates and DAQ status | ||
* upload monitoring plots (mon12) to logook | * upload monitoring plots (mon12) to logook | ||
− | ** '''look at the spectra''': Reference, current, and 5 most recent runs, choose a reference run (the reference numbers refer to logbook entries): | + | ** [https://clas12mon.jlab.org/mon12/histograms/?reference=4002157 '''look at the spectra''']: Reference, current, and 5 most recent runs, choose a reference run (the reference numbers refer to logbook entries): |
** In particular, take note of the new Raster Monitoring interface - see "Monitoring" Tab. | ** In particular, take note of the new Raster Monitoring interface - see "Monitoring" Tab. | ||
Revision as of 12:37, 13 June 2022
- Shift Documentation
- Phone Numbers
- Short Term Schedule
- Shift Expert
- Worker Shift
- Monitoring
- Useful Links
Shift ScheduleHall B LogbookESAD, COO, RSADShift ChecklistHot CheckoutBeam Time Accounting
|
Manuals
|
Procedures |
JLab Logbooks
|
NOTE: All NON-JLab numbers MUST be dialed with (757) area code. When calling from a CH landline, dial "9" first.
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
CLAS12 Run Group C, Summer 2022
Daily RC Meetings at 14:00: CH Room 200C, and on Zoom
Zoom information: Link, Meeting ID: 160 867 4253, Passcode: 786506
- Dial "9" before all numbers when calling from CH
Run Group Coordinator: Sebastian Kuhn
- (9-)757 639-6640
RC: Sebastian Kuhn
- (9-)757 575-7540 or
- (9-)757 639-6640
PDL: Eugene Pasyuk
- (9-)757 876-1789 , x6020 office
Run Coordinator and Target Expert Schedule
Longterm Run Plan
IMPORTANT NOTES:
- If you have symptoms or a positive COVID test, do NOT come to your shift - instead, inform the PDL and the RC immediately so that replacements can be arranged
- If needed, worker shifts can also be taken from off-site - again, inform the PDL and RC. Also, make sure that you follow the instructions under the "Worker Shift" Tab - you need some lead time to set up!
- Before leaving the hall and going to beam permit check that dome lights, forward carriage lights, and pie tower lights are OFF
- NEW: We have a new policy NOT to leave the beam viewer in the beam at all times, to avoid damage to electronics, cameras etc. Please ask MCC to REMOVE the beam viewer unless we are actively tuning the beam or calibrating beam position/raster.
- NEW: We have a new FSD condition that the raster is operating.
- IF there is any ammonia sample (NH3 and ND3) in the target, the raster MUST be operating at all times. The Raster FSD must be UNMASKED.
- For beam tuning or other non-rastered beam, the Raster FSD must be MASKED.
- REMINDER FOR ALL EXPERTS: Please take care to fill out the BTA carefully and correctly. The info from EPICS is not always correct, e.g. when taking data with low beam current, you should change the ABU to the proper (estimated) time by hand instead of simply accepting "0" if you are actually taking data.
Run Plan: June 2022
- plan for owl Sa, 12-Jun-2022: run on empty target
- finish raster test (run 16042)
- raster off, mask on raster can stay, orbit lock on
- all detectors ON
- luminosity scan 5-25nA (watch DC occupancy, trigger rate ca 10kHz max)
- run 100 million or 4 hours on empty target
- call Eugene and ask to ramp down magnets, then run with 1nA until shift ends
- All shifts are cancelled until Saturday 7:00 a.m.
- Fri, 6/10: Target maintenance. Install cross-hair target probe for beam. (No LHe in target)
- Sat, 6/11: Establish beam following "Physics-Quality Beam" Procedure under "Shift Documentation" tab.
- Center beam on target, using rates in downstream beam monitors. Establish wire positions (2H01 x and y). Center beam on target and turn on orbit lock on 2C24.
- Follow Raster Manual under "Shift Documentation" tab to calibrate raster settings.
- Turn on rastering and check all alarms and interlocks (unmask raster FSD).
- Take one run with standard DAQ and raster to check RasterMon.
- Turn raster off and mask raster FSD. Scan beam current up to 50 nA while keeping DAQ trigger rate below 10 kHz and all occupancies in reasonable range (check with clas12mon).
- Take one run with raster off and beam current as established above (2-4 hours).
- Finalize raster setup and set CCDB parameters.
- Sun, 6/11:
- If time, take a zero field run (sub-1 nA).
- Swap to 12C target. Do a current scan to determine optimum combination of raster size and luminosity.
- Complete other calibration runs as requested: DC HV, BMT HV, TOF.
- Early next week: Take data with MT, 12C and polarized NH3 targets.
- If time allows, take data on CH2, CD2 and polarized ND3.
- Then change from 1-pass to 5 pass.
1-pass (2.1 GeV) Running conditions
- Torus at 50% current, inbending electrons. Setpoint +1885 A
- Solenoid setpoint +2417.5 A
- Establish optimal compromise between raster size (if possible, 7 mm radius), luminosity (goal: 5 nA), and background.
- Run duration 100M events or 4 hours, whichever comes first.
- For empty target runs, increase beam current as much as possible (up to 50 nA).
DAQ configuration
- Configuration PROD66_PIN, trigger file rgc_100MeV_V1.0_no_DC.trg
- NOTE: UNLESS a RICH problem crashes the DAQ, do NOT interrupt an otherwise smooth run to do a RICH recovery - instead do this in between runs.
- NOTE: BOTH the shift expert AND the shift worker MUST check and reset monitoring histograms at least once every 30-60 minutes to make sure there are no major detector problems.Watch the raster pattern!
- At the end of each run, follow the STANDARD DAQ RESTART SEQUENCE:
- "end run", if the run ended correctly then: "prestart", "go"
- if the run did not end correctly or if any ROCs had to be rebooted:
- "cancel", "reset"
- "configure", "download", "prestart", "go"
- After each step, make sure it is completed in the Run Control message window. If a ROC has crashed, find which one it is, issue a roc_reboot command ON JUST THAT ROC and try again. Contact the DAQ expert if there are any questions.
References and Standards
Solenoid set-point of 2417.5 A results in read back 2419.57 A and exactly 5.00 T field on center
Nominal Beam Positions
- 2H01, X: -0.2 mm, Y: -0.2 mm (only used/useful without rastering)
- 2C24, X: -2 mm, Y: 0.6 mm (orbit lock)
FSD Thresholds (to be updated)
- Upstream: 2000 Hz
- Midstream: 2000 Hz
- Downstream: 500000 Hz
- BOM: masked. Not used in this run.
- 5 ms dwell time
Reference Harp Scans for Beam on Faraday Cup 2H01 [1]
Reference Harp Scans for Beam on Tagger dump 2C21 [2], tagger harp [3]
Reference Monitoring Histograms
Counter rates
- Upstream counters integrated rates: 0-15 Hz (acceptable up to 100 Hz are acceptable) @50 nA.
- Midstream counters: 10-20 Hz (acceptable up to 50 Hz) @50 nA.
- Counting rates of ~ hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.
NOTE: BOTH the shift expert AND the shift worker MUST check monitoring histograms at least once every 30 - 60 minutes to make sure there are no major detector problems.
(remote) shift worker: see dedicated Worker Shift tab above. |
For REMOTE Shifts (offsite):
Shift Worker TasksEvery Run:
Every Shift:
Regularly:
|
|
Webcams
|
Manuals |
Epics on the web
|
Live Monitoring Links |
Hall-B |
Accelerator |
ZOOM meetings
|