Difference between revisions of "Run Group A"
Jump to navigation
Jump to search
Line 102: | Line 102: | ||
'''</font> | '''</font> | ||
− | === Updated Feb- | + | === Updated Feb-24, 15:16 === |
* ''Sat Feb 23: Take data with 35 nA beam until Sergei creates the new trigger file'' | * ''Sat Feb 23: Take data with 35 nA beam until Sergei creates the new trigger file'' | ||
* ''When Sergei comes he will test the new trigger file with 50 nA beam '', if it works, then the plan for the weekend is to take production data with 50 nA beam. | * ''When Sergei comes he will test the new trigger file with 50 nA beam '', if it works, then the plan for the weekend is to take production data with 50 nA beam. | ||
− | * ''' Before Accelerator gets beam off for beam studies we should take empty target run, It will | + | * ''' Before Accelerator gets beam off for beam studies we should take empty target run, It will be around Monday 7 AM. RC will notify later if the time for empty target runs is changed ''' |
* ''' Monday when MCC takes the beam off we might go to "Restricted access" during beam studies. ''' | * ''' Monday when MCC takes the beam off we might go to "Restricted access" during beam studies. ''' |
Revision as of 15:10, 24 February 2018
[edit]
Shift ScheduleShift ChecklistHot CheckoutBeam Time Accounting
|
Manuals |
Procedures |
JLab Logbooks
|
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 Run Group A, Winter 2018
Beam energy 10.6 GeV (5 pass)
Important: Document all your work in the logbook!
Remember to fill in the run list at the beginning and end of each run (clas12run@gmail.com can fill the run list)
RC: Rafayel Paremuzyan
- (757) 575-7540
- 9 575 7540 from Counting Room
- rafopar@jlab.org
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
- pasyuk@jlab.org
- Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.
- Note 2: At the end of each run, follow the DAQ restart sequence "end run", "abort", "reset", "download", "prestart", "go". After DAQ prestart is complete reboot the scaler IOCs with the command: iocjscalerRestartAll.sh. Note: After each step, make sure it is complete in the Run Control message window. If a roc has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
- Note 3: Nominal beam positions: 2H01 (X=1.0 mm, Y=-1.5 mm)
- Note 4: With beam to the Faraday Cup, typical rates on all halo counters upstream from the target should be either 0 or of the order of few counts. Count rates in the range of tens or more may indicate bad beam tune or bleed-through from other Halls.
Run Plan:(last update 2/20 - 1:15 AM)
Updated Feb-24, 15:16
|
General Instructions:
Every Shift:
Every Run: Log screenshots of:
|
Webcams |
Manuals |
Epics on the web
|
Hall-B
Run lists |
Accelerator |
Bluejean meetings
|