Line 121: | Line 121: | ||
* <font color=red> ======== Do not start the runs below without approval from RC ==========</font> | * <font color=red> ======== Do not start the runs below without approval from RC ==========</font> | ||
− | *Then switch to luminosity scan, still with the constrain of having a stable beam. Take the following runs with trigger_v11_e_only: | + | *Then switch to luminosity scan, still with the constrain of having a stable beam (see the following address [https://logbooks.jlab.org/entry/3549055]). Take the following runs with trigger_v11_e_only: |
** 5 nA - 4 hours (3.5 M events) | ** 5 nA - 4 hours (3.5 M events) | ||
** 10 nA - 2 hours (3.5 M events) | ** 10 nA - 2 hours (3.5 M events) | ||
** 35 nA - 0.5 h (6 M events) | ** 35 nA - 0.5 h (6 M events) | ||
** 50 nA - 0.5 h ( 8.5 M events) | ** 50 nA - 0.5 h ( 8.5 M events) | ||
− | ** 75 nA - 0.5 h (12M events). | + | ** 75 nA - 0.5 h (12M events) <= Call SVT expert for this run. |
<!-- === Updated March 6, 9:39 === | <!-- === Updated March 6, 9:39 === |
Revision as of 21:37, 27 March 2018
[edit]
Shift ScheduleShift ChecklistHot CheckoutBeam Time Accounting
|
Manuals |
Procedures |
JLab Logbooks
|
If calling local numbers (with area code prefix 757) from the counting room dial 9+[last 7 digits]. To call other area codes dial 91+[10 digit number]
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 Run Group A, Spring 2018
Beam energy 10.6 GeV (5 pass)
Important: Document all your work in the logbook!
Remember to fill in the run list at the beginning and end of each run (clas12run@gmail.com can fill the run list)
RC: Maxime Defurne
- (757) 575-7540
- 9 575 7540 from Counting Room
- mdefurne@jlab.org
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
- pasyuk@jlab.org
- Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.
- Note 2: At the end of each run, follow the DAQ restart sequence "end run", "abort", "reset", "download", "prestart", "go". After DAQ prestart is complete reboot the scaler IOCs with the command: iocjscalerRestartAll.sh. Note: After each step, make sure it is complete in the Run Control message window. If a roc has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
- Note 3: Nominal beam positions: 2H01 (X=1.0 mm, Y=-1.5 mm)
- Note 4: With beam to the Faraday Cup, typical rates on all halo counters upstream from the target should be either 0 or of the order of few counts. Count rates in the range of tens or more may indicate bad beam tune or bleed-through from other Halls.