*# ask MCC to degauss and turn the tagger dipole off; | *# ask MCC to degauss and turn the tagger dipole off; | ||
*# position 20 mm collimator on the beam and move \Chromox" screen of the downstream viewer in beam position (if it is not already) | *# position 20 mm collimator on the beam and move \Chromox" screen of the downstream viewer in beam position (if it is not already) | ||
+ | *# move the beam blocker out: in this configuration beam current readings at 2C24, 2H01 and Faraday Cup should be close. | ||
*# ask for <= 1 nA, positions, quads settings and rates should be as in https://logbooks.jlab.org/entry/3502404; pay particular attention to halo counter rates: if very different from what shown in the link, call MCC and ask them to verify their settings; note that BOM gains were lowered today and rates should be lower (see https://logbooks.jlab.org/entry/3502559). | *# ask for <= 1 nA, positions, quads settings and rates should be as in https://logbooks.jlab.org/entry/3502404; pay particular attention to halo counter rates: if very different from what shown in the link, call MCC and ask them to verify their settings; note that BOM gains were lowered today and rates should be lower (see https://logbooks.jlab.org/entry/3502559). | ||
− | *# make sure beam is stable, beam spot is clearly visible on the chromax viewer | + | *# make sure beam is stable, beam spot is clearly visible on the chromax viewer and current does not exceed 1 nA; |
*# repeat harp scans at 2c21, 2c24 (tagger harp) and 2h01: profile should be as in https://logbooks.jlab.org/entry/3502250, https://logbooks.jlab.org/entry/3502252 and https://logbooks.jlab.org/entry/3502313. Make sure you select the proper PMT for the analysis. The profile at 2c21a and 2c24 should be as in the scans performed with beam to the tagger. If necessary ask MCC to adjust the beam profile at 2H01 to match the previous scan. | *# repeat harp scans at 2c21, 2c24 (tagger harp) and 2h01: profile should be as in https://logbooks.jlab.org/entry/3502250, https://logbooks.jlab.org/entry/3502252 and https://logbooks.jlab.org/entry/3502313. Make sure you select the proper PMT for the analysis. The profile at 2c21a and 2c24 should be as in the scans performed with beam to the tagger. If necessary ask MCC to adjust the beam profile at 2H01 to match the previous scan. | ||
− | * once beam tuning is complete ask for 1.5 nA and ask MCC to unmask the FSD. | + | * once beam tuning is complete move the beam blocker in (beam should be off for this), ask for 1.5 nA and ask MCC to unmask the FSD. |
+ | * ask MCC to use BPM current readings from 2H01 for current lock (see https://logbooks.jlab.org/entry/3502484) | ||
* turn on the forward carriage detectors: EC, PCAL, FTOF; check rates and record them in the logbook; | * turn on the forward carriage detectors: EC, PCAL, FTOF; check rates and record them in the logbook; | ||
* if rates are consistent with previous, proceed to turning on LTCC, DC, HTCC; | * if rates are consistent with previous, proceed to turning on LTCC, DC, HTCC; |
Revision as of 19:02, 11 December 2017
[edit]
Shift ScheduleShift ChecklistHot CheckoutBeam Time Accounting |
Manuals |
Procedures |
JLab Logbooks
|
|
|
- Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
- To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
- Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.
Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.
CLAS12 Engineering Run, Fall 2017
Beam energy 10.6 GeV (5 pass)
Important: Document all your work in the logbook!
RC: Raffaella DeVita
- (757) 575-7540
- 9 575 7540 from Counting Room
- devita@jlab.org
PDL: Eugene Pasyuk
- (757) 876-1789
- 9 876-1789 from Counting Room
- pasyuk@jlab.org
Run Plan:
|
General Instructions:
|
Every Shift:
|
Every Run:
|
---|
Webcams |
Manuals |
Epics on the web
|