Difference between revisions of "Run Group K"

From clas12-run
Jump to navigation Jump to search
(Created page with "= Shift Documentation = <!--####################################### SHIFT DOCUMENTATION ########################################--> {| {{TableStyle1}} | valign=top | <!--==...")
 
Line 67: Line 67:
 
<center><font color=blue size=4>
 
<center><font color=blue size=4>
 
''' CLAS12 Run Group K, Fall 2018 </font> '''<br>
 
''' CLAS12 Run Group K, Fall 2018 </font> '''<br>
<font color=red size=8> '''Run is Over!'''</font> <br>
 
 
''' Beam energy 10.6 GeV (5 pass) '''<br>
 
''' Beam energy 10.6 GeV (5 pass) '''<br>
 
''' Important: Document all your work in the logbook! '''<br>
 
''' Important: Document all your work in the logbook! '''<br>
Line 74: Line 73:
 
</center>
 
</center>
  
== RC: Somebody ==
+
== RC: Annalisa D'Angelo ==
 
* (757) 575-7540   
 
* (757) 575-7540   
 
* 9 575 7540 from Counting Room
 
* 9 575 7540 from Counting Room
* [mailto:somebody@jlab.org somebody@jlab.org]
+
* [mailto:annalisa@jlab.org annalisa@jlab.org]
  
 
== PDL: Eugene Pasyuk ==
 
== PDL: Eugene Pasyuk ==
Line 87: Line 86:
  
 
* '''Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.'''
 
* '''Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.'''
The integrated rates on UPSTREAM counters has to be in the range 0-15 Hz (rates up 100 Hz are acceptable) and MIDSTREAM has to be in the rage 10-20 Hz (acceptable up to 50 Hz) @50 nA. Count rates in the range of hundreds or more may indicate bad beam tune or bleed-through from other Halls.
+
The integrated rates on the upstream counters have to be in the range 0-15 Hz (rates up 100 Hz are acceptable) and the rates on the midstream counters have to be in the range 10-20 Hz (acceptable up to 50 Hz) @50 nA. Counting rates in the range of hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.
  
* ''' Note 2: At the end of each run, follow the DAQ restart sequence '''
+
* ''' Note 2: At the end of each run, follow the standard DAQ restart sequence '''
 +
"end run", "cancel", "reset", then if the run ended correctly, '''"download", "prestart", "go"'''. If the run did not end correctly or if any ROCs had to be rebooted, "configure", "download", "prestart", "go".
  
''' "end run", "cancel", "reset"''', then
+
After each step, make sure it is complete in the Run Control message window. If a ROC has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
  
if run ended correctly ''' "download", "prestart", "iocjscalerRestartAll.sh", "go". '''
+
* '''Note 3: Nominal beam positions: <font color=red>''' ''' 2C24A (X=0.2 mm, Y=0.2 mm) ''', '''2H01 (X=0.3 mm, Y=-0.9 mm)''' </font>
  
if run did not ended correctly, or ROCs had to be rebooted '''"Configure", "download", "prestart", "iocjscalerRestartAll.sh", "go". '''
+
* '''Note 4: Do not turn OFF FTOF HVs, even during the beam tune with CW beam (turn off when doing a Moller run or if there is tuned/pulsed beam in the upstream beamline)'''
  
After DAQ prestart is complete reboot the scaler IOCs with the command:'''  iocjscalerRestartAll.sh. '''
+
* '''Note 5: In case of a Torus and/or Solenoid Fast Dump do the following:
 
+
*# Notify MCC to request beam OFF and to drop Hall B status to Power Permit
Note: After each step, make sure it is complete in the Run Control message window. If a roc has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
 
 
 
* '''Note 3: Nominal beam positions:''' ''' 2C24A (X=0.5,Y=0.5) ''', '''2H01 (X=1.0 mm, Y=-1.0 mm)''' see log entry https://logbooks.jlab.org/entry/3570290.
 
 
 
* '''Note 4: Do not turn OFF FTOF HVs, even during the beam tune'''
 
 
 
* '''Note 5: In case of the Torus and/or Solenoid Fast Dump do the following -
 
*# Notify MCC, request beam OFF and drop Hall status to Power Permit
 
 
*# Call Engineering on-call
 
*# Call Engineering on-call
*# Make separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" filed add Ruben Fair, Probir Goshal, Dave Kashy and esr-users@jlab.org  
+
*# Make separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Ruben Fair, Probir Goshal, Dave Kashy and esr-users@jlab.org  
 
*# Notify Run Coordinator
 
*# Notify Run Coordinator
*# Call the MM expert to turn the detector off
+
*# Turn off all detectors'''
*# Call SVT expert to turn SVT off
 
*# Turn off all the other detectors'''
 
  
*'''Note 6: When beam is being delivered to the Faraday Cup -'''
+
*'''Note 6: When beam is being delivered to the Faraday Cup:'''
*# the Fast Shut Down: Upstream, Midstream, Downstream, BOM and Solenoid should be always <font color=red> Unmasked</font>,
+
*# the Fast Shut Down elements: Upstream, Midstream, Downstream, BOM, and Solenoid should always be in the state <font color=red>UNMASKED</font>
*# No changes to the FSD threshold without RC or beamline expert approval.
+
*# No changes to the FSD threshold should be made without RC or beamline expert approval
 +
<!--*'''Note 7: Do not turn on the SVT or MM - only the SVT or MM expert can do that''' -->
  
*'''Note 7: Do not turn on or off SVT - only SVT expert can do that'''
+
*'''Note 7: Any request for a special run or change of configuration has to be approved by the RC & documented'''
*'''Note 8: Any request for a special run or change of configuration has to be approved by RC & documented.'''
 
*'''Note 9: Check carefully BTA every hour and run script <font color=red> btaGet.py </font>. It will  print for you what HAS TO BE in BTA for this hour. Edit BTA if it is incorrect.'''
 
*'''Note 10: Reset CLAS12MON frequently to avoid histogram saturation.'''
 
  
{| {{TableStyle1}}
+
*'''Note 8: Carefully check the BTA every hour and run the script <font color=red>btaGet.py</font> to print for you what HAS TO BE in BTA for this hour. Edit BTA if it is incorrect.'''
  
| valign=top width=50% |
+
*'''Note 9: Reset CLAS12MON frequently to avoid histogram saturation.'''
  
== <font color=blue>''' Run Plan: May3-May 6 '''</font>==
+
*'''Note 10: Shift workers must check the occupancies! Use this tool to compare to previous runs: [https://clas12mon.jlab.org/mon12/histograms/ https://clas12mon.jlab.org/mon12/histograms/]'''
  
 +
*'''Note 11 Do not Turn OFF MVT HV: Instead go to 'Restore settings' from the MVT overview screen:
 +
*# SafeMode.snp for beam tuning and Moeller runs
 +
*# MV_HV_FullField.snp for full solenoid field
 +
*# MV_HV_MidField.snp wgeb solenoid < 4T
 +
'''
 +
*'''NOTE 12 Check the vacuum periodically, make sure vacuum id not higher than 5e-5 '''
  
May 4 (Day/Swing)
+
*''' NOTE 13 Always reset the CFD threshold after all power off/on on the CFD crate'''
There are a series of special runs planned.
+
After the CAMAC crate 1 holding the CND CFD boards is switched
 +
off for any reason, it is mandatory to reset the associated thesholds typing the
 +
following command from any clon machine terminal:
 +
>> $CODA/src/rol/Linux_x86_64/bin/cnd_cfd_thresh -w 0
  
1. FT-only trigger runs: Genova group (Raffaella/Andrea) just finished this run
+
*'''NOTE 14: As of 10/25, the issue of detector scalers being frozen and starting a new run has been resolved.''' Shift workers should anyway check routinely scalers to verify they update correctly and make a logbook entry if anomalies are observed after starting a new run.
  
2. Random-trigger with existing PCAL/FTOF map: Started around 9am and should conclude around 2pm. If there is any issue, contact Andrea via bluejeans.com/1342978709
+
*'''NOTE 15: To solve common SVT issues see https://logbooks.jlab.org/entry/3615766'''
  
For 3--5, Sergey will take control of DAQ
+
{| {{TableStyle1}}
 
 
3. DAQ studies(Sergey): Starting from 2:00pm. Sergey must be notified around 1:30pm if he is not already in the counting house. This is a series of short runs
 
 
 
4. DC/Varying readout window size/current scans: This will be a series of short runs (~30min each). For exact setting, please contact Volker (phone # on white board); Sergey will implement the changes.
 
 
 
5. Mode 7: Sergey will perform this run (~2 hrs). Dan should be contacted if needed via FTOF expert phone.
 
 
 
May 4(Swing) --- May 6th (Owl)
 
 
 
When the above special runs are finished. Resume production runs at 50nA with trigger_v12_3.cnf
 
 
 
 
 
 
 
'''May 6 at 5 am''' MCC will terminate beam delivery.<br>
 
 
 
Start preparation for summer shutdown after that
 
* '''Turn HV OFF for:'''
 
** '''DC'''
 
** '''FTOF'''
 
** '''ECAL/PCAL'''
 
** '''LTCC'''
 
** '''HTCC'''
 
** '''FTT'''
 
** '''BMT/FMT'''
 
** '''CTOF'''
 
** '''CND'''
 
* '''Detectors remain ON for post calibrations:'''
 
** '''RICH'''
 
** '''SVT'''
 
** '''FTC/FTH'''
 
** '''Cryotarget stays FULL'''
 
* '''Turn OFF Solenoid and Torus''' (call PDL)
 
 
 
 
 
May 6 7am.
 
 
 
A small reception full of fancy food will be held in the counting house at 7am for the early birds. No reservation needed. Dress code: photo-friendly.
 
 
 
* From time to time, we might experience trigger bit issues (FT bits: 24, 25, and 26 and 27). bit 26 might not trigger the alarm but when this issue happens it will count abnormally high pre-prescale. For the time being, shift leaders cand try to do the sequence of End->Cance->Reset, roc_reboot adcft1 (and adcft2, adcft3), make sure the roc are connected, then Download->Prestart->Go. If this does not work, repeat the sequence and add "Configure" in front of "Download". If the trig issue persist, please continue take production data without fixing it -- please make sure you log this infor in the RCDB "Comment" field.
 
 
 
* If the machine is down for few hours ask for low current first 5 nA make sure that the beam is stable both in  position and current, check that the rates are OK on all the detectors and halo counters. Then ask for 50 nA and continue data for production. If there are issues with the beam call the RC. Sometimes MCC operator might ask to deliver tune beam --- please do not accept it. We need CW beam sent to the Faraday cup. If there is in deed a need for tune beam, it should be sent to the tagger dump with the tagger magent on. If you are uncertain, please call RC/PDL.
 
 
 
 
 
* <font color=red>'''Please contact the Micromegas (BMT, FMT & FTT) expert if there are trips, or if you notice any issues in the online monitoring. Do not turn OFF or ON the MM only the expert  can do that. See Log entry https://logbooks.jlab.org/entry/3556528 '''</font>
 
 
 
Sometimes, a couple of RICH channel scalers would go to 0 and there is no alarm, even though the "# of fjibers connected" would be shown to be the correct 138. Shift takers therefore should periodically, especially at the end of run, check the RICH scalers GUI. If there is an issue, please refer to the instruction below.
 
 
 
* <font color=red>'''For RICH recovery procedures, please see Log entry https://logbooks.jlab.org/entry/3562273.  This would apply in the cases of  1. DAQ crash: rich4 is not responding or 2. RICH alarms (LV,missing tile, temperature etc). If it does not work or you are uncertain about what to do, please contact the RICH expert on call '''</font>
 
 
 
 
 
 
 
 
 
'''In case of other questions or uncertainties of what to do, please call the RC'''
 
 
 
 
 
 
 
<!-- === Updated March 6, 9:39 ===
 
*Due to the power failure, accelerator will be off for some extended time. All shifts are canceled for the 48 hours.
 
Next staffed shift will be Thursday, March 8'th expert day shift.
 
*Machine update https://logbooks.jlab.org/entry/3543255
 
-->
 
<!--
 
Due to the power failure, accelerator will be off for some extended time. All shifts are canceled for the 24 hours. Next staffed shift will be Tuesday, March 6'th expert swing shift.
 
Machine update https://logbooks.jlab.org/entry/3543255
 
 
 
*Take data with the 50 nA beam, trigger file trigger_v9.cnf, 100M  events per run.
 
*Monitor livetime closely.
 
 
 
* ''Sat Feb 23: Take data with 35 nA beam until Sergei creates the new trigger file''
 
* ''When Sergei comes he will test the new trigger file with 50 nA beam '', if it works, then the plan for the weekend is to take production data with 50 nA beam.
 
 
 
* ''' Before Accelerator gets beam off for beam studies we should take empty target run, It will be around Monday 7 AM. RC will notify later if the time for empty target runs is changed '''
 
 
 
* ''' Monday when MCC takes the beam off we might go to "Controlled access" during beam studies. Please ask MCC for controlled access with Radiation survay  '''
 
* ''' Monday when hall is sweeped, ask MCC to energize the tagger magnet, and then follow instructions in section 1 "Beam to tagger-yoke dump" from this link https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf  '''
 
 
 
* ''' When good beam is establisged on tagger magnet Yoke, we should do two Moller runs, 1st with half wave plate OUT, and 2nd with half wave plate "IN", please follow instructions in this link https://wiki.jlab.org/clas12-run/images/1/1d/Moller.pdf'''
 
 
 
* ''' When Moeller runs are finished, ask MCC to deGaus the tagger magnet, and follow instructions for sending the beam to Faraday Cup  https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf Section 2'''.
 
 
 
* ''' As soon a good beam is established (good harpscan, beam is centered in FTCalo), then turn on HV on detectors, and start taking data with trigger_v7 '''.
 
* ''' We want to check whether we can go to a higher current 55 nA, and check whether DAQ is stable and livetime is around 90%, if it works, then we should keep the 55 nA beam current, otherwise we should go back to 50 nA '''
 
-->
 
<!--
 
The beam position should be as indicated above. Make sure FSD thresholds are set correctly for whatever current is selected (refer to instructions in the "Establish-physics quality beam" procedure at [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf]), integration time is set to 5 ms, and that the orbit locks are on. -->
 
  
 +
| valign=top width=50% |
  
<!--
+
<i>(Updated: Nov. 20, 2018 at 11:50>/i>
<font color=blue>''' February 20 swing, February 21 owl and day shifts Run Plan'''</font>
+
* Before beam delivery ramp torus to -3770 A (100% field - negatives outbending) and solenoid to 2416 A (100% field); empty target and turn all detectors off
 +
* Tune beam in upstream beamline following nominal procedures
 +
* Take Moller run
 +
* Tune 5 nA beam to Faraday Cup following nominal procedures
 +
* Ensure the beam position at the target is optimized for minimal rates
 +
* Take 2 hr empty target run (beam current TBD)
 +
* Begin to optimize DAQ and trigger setup
 +
* Turn beam off and fill target
 +
* Take 2 hr run with 5 nA
 +
* Complete initial trigger studies
 +
* Production with configuration PROD66 and '''trigger_v23.trg''' at '''30''' nA.
 +
* Any questions or uncertainty about what to do please call RC
  
* Take data with a production trigger trigger_v4.trg untill 1 PM Wed. Feb. 21, and at 1PM call MCC and request "Restricted" access.
+
'''<font color=red> Make sure to save ROC Rates (MB/s) GUI to logbook for each run together with beam screens and trigger GUI </font>'''
** HV on all detectors should be off, except SVT you can turn HV off, for SVT call Yuri and ask to turn SVT HV off
+
** Call PDL (Eugene) and ask to rump Solenoid and Torus down.
+
* <font color=blue> ''' Make sure that the FSD thresholds are set correctly and they are unmask when ready to receive beam to the FC @50 nA
 +
** Upstream 2000
 +
** Midstream 1000
 +
** Downstream 900000
 +
** BOM 15000
 +
** Dwell time 5 ms
 +
'''</font>
  
* When we back again to beam permit, we should directly go into FCup
+
== <font color=blue>''' Shift Worker Notes:'''</font>==
** Eugune will rump up Solenoid and Torus magnets
 
** Make sure Solenoid FSD is unmasked "There should not be any Yellow or Red lights under the Solenoid FSD"
 
** Make sure HV on all detectors are off except FT CALO.
 
** Tagger magnet is "OFF"
 
** Collimator is at '20 mm' position
 
** Request for 2 nA beam
 
  
** Make sure Solenoid FSD is unmasked "There should not be any Yellow or Red lights under the Solenoid FSD"
+
<!-- * From time to time, we might experience trigger bit issues (FT bits: 24, 25, 26, 27). Bit 26 might not trigger the alarm but when this issue happens it will count abnormally high. For the time being, shift leaders can try to do the sequence of End->Cancel->Reset, roc_reboot adcft1 (and adcft2, adcft3), make sure the ROCs are connected, then Download->Prestart->Go. If this does not work, repeat the sequence and add "Configure" in front of "Download". If the trig issue persists, continue to take production data without fixing it -- please make sure you log this infor in the RCDB "Comment" field. -->
** Make sure HV on all detectors are off except FT CALO.
 
** Tagger magnet is "OFF"
 
** Collimator is at '20 mm' position
 
** Request for 5 nA beam
 
  
** Look carefully int Halo counters, all halo counters upstream of the target are counting less than 10 Hz
+
* If the machine is down for more than 30 min ask for low current first 5 nA ,make sure that the beam is stable both in position and current, check that the rates are OK on all the detectors and halo counters. Then ask for 45 nA and continue data for production. If there are issues with the beam call RC. Sometimes MCC operator may ask to deliver tuned mode beam --- do not accept it. We need CW beam sent to the Faraday cup. If there is indeed a need for tuned beam, it should be sent to the tagger dump with the tagger magnet on. If you are uncertain, please call RC/PDL.
** Look into FT Calo scaler screen, which is the main measure how the beam is centered, for reference look https://logbooks.jlab.org/entry/3535015 this, and make sure X and Y asymmetry is close to 0 (less than +/-6% with 2 nA beam, and less than 3% when you go to production current).
 
** If the beam is centered enough and halo rates on midstream and upstream halo counters don't exceed few Hz, request for 20 nA beam, and ask out orbit lock to be engaged. Check again beam is centered, and halo counters still coun order of few Hz.
 
** Check also beam position on 2H01, should be around '''2H01 (X=1.0 mm, Y=-1.5 mm)'''
 
  
* Next step is to do harp scans with all three harps, 2c21 harp, tagger harp and 2H01 harp
+
<!--* Sometimes, a couple RICH channel scalers go to 0 and there is no alarm, even though the "# of fibers connected" would be shown to be the correct 138. Shift takers therefore should periodically, especially at the end of run, check the RICH scalers GUI. If there is an issue:-->
** Before 2C21 and tagger harps scans put Upstream and midstream FSD thresholds to 100000, and the integration time 50ms.
+
* For RICH recovery procedures, please see Log entry https://logbooks.jlab.org/entry/3562273.  This would apply in the cases of  1. DAQ crash: rich4 is not responding or 2. RICH alarms (LV,missing tile, temperature etc). If it does not work or you are uncertain about what to do, contact the RICH expert on call.
** You should not see any signifcant halo, the bgr/Peak ratio should be below 5e-3
 
** As soon you are done with 2c21 and tagger harp scans, put back FSD hresholds for upstream and midstream counters to 1000, and integration time to 5 ms.
 
  
** For 2H01 harp scan, ask BOM limit to be 1000000 and itegration time 50 ms. then do 2H01 harp scan. Compare harp scan result to the most recent one https://logbooks.jlab.org/entry/3534806, make sure beam sigmas are close to the one in the link.
+
'''In case of other questions or uncertainties of what to do, call the RC'''
  
* Next step is to tur HV on for detectors, for '''SVT''' only call Yuri and ask him to turn SVT HV on.
+
<!--'''[[Every Shift:]]'''
* Sergei has added a new component PCal Ustrips (PCU) in the trigger, it's timing should be checked, call sergei and ask him to take over the DAQ to adjust the relative timing of PCU. This should approximetely take about 1 hour.
 
* As soon Sergei has finished timing adjustment, ask for 35 nA beam, and take production data with trigger_v5.trg
 
-->
 
<!-- * If the machine is down and it is back start with low current first  (2nA and 5 nA)  making sure that the beam is stable in current and position before moving to 30 nA
 
-->
 
 
 
 
 
 
 
 
 
<!--
 
'''[[Every Shift:]]'''
 
 
*Follow run plan as outlined by RC
 
*Follow run plan as outlined by RC
 
* If any concern about beam stability, ask MCC if orbit locks are on (they should be).
 
* If any concern about beam stability, ask MCC if orbit locks are on (they should be).
 
* Keep shift summary up to date in HBLOG. Record all that happens.
 
* Keep shift summary up to date in HBLOG. Record all that happens.
* Check on white board all scalers, strip charts and monitoring plots that need to be logged regularly
 
 
* Document any beam condition change and send scaler GUIs to HBLOG
 
* Document any beam condition change and send scaler GUIs to HBLOG
 
* [https://bta.acc.jlab.org Fill out BTA] hourly.  Click "Load from EPICS" to automatically fill the left side.
 
* [https://bta.acc.jlab.org Fill out BTA] hourly.  Click "Load from EPICS" to automatically fill the left side.
 +
 
*Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook]
 
*Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook]
  
Line 282: Line 186:
 
* main scaler GUI display
 
* main scaler GUI display
 
* Detector occupancy plots
 
* Detector occupancy plots
* Trigger rate gui
+
* Trigger rate GUI
 
* Beam strip charts
 
* Beam strip charts
* FTCalo FADC scalers
+
* FT-Cal FADC scalers
 +
-->
  
-->
 
 
| valign=top |
 
| valign=top |
  
Line 297: Line 201:
 
* In case of loss of communication with IOCBTARG, follow instructions at https://logbooks.jlab.org/entry/3502218
 
* In case of loss of communication with IOCBTARG, follow instructions at https://logbooks.jlab.org/entry/3502218
 
* With any issue contact On-Call Experts or RC - do not spend more than 15-20 min trying to fix the problem.  
 
* With any issue contact On-Call Experts or RC - do not spend more than 15-20 min trying to fix the problem.  
* All jscaler iocs (iocjscalerX) on the health screen (under DAQ tab) must be restarted after every DAQ prestart is completed. Follow this link for detailed instructions https://userweb.jlab.org/~baltzell/CLAS12/SC/jlabScalersOps.txt
+
<!--* All jscaler iocs (iocjscalerX) on the health screen (under DAQ tab) must be restarted after every DAQ prestart is completed. Follow this link for detailed instructions https://userweb.jlab.org/~baltzell/CLAS12/SC/jlabScalersOps.txt-->
* Check that no unecessary beamline-related screens are open.  This includes particularly the big beamline overview screen, but also and any motor/harp/collimator screens, and ioc health screens.
+
* Check that no unnecessary beamline-related screens are open.  This includes particularly the big beamline overview screen, but also and any motor/harp/collimator screens, and ioc health screens.
 +
* Reference harp scans: [https://logbooks.jlab.org/entry/3571664 2C21], [https://logbooks.jlab.org/entry/3571676 2C24], [https://logbooks.jlab.org/entry/3571859 2H01]
  
 
'''Every Shift:'''
 
'''Every Shift:'''
Line 307: Line 212:
 
* Document any beam condition change and send scaler GUIs to HBLOG
 
* Document any beam condition change and send scaler GUIs to HBLOG
 
* [https://bta.acc.jlab.org Fill out BTA] hourly.  Click "Load from EPICS" to automatically fill the left side.
 
* [https://bta.acc.jlab.org Fill out BTA] hourly.  Click "Load from EPICS" to automatically fill the left side.
 +
* When you do BTA keep track of of BANU. Include at the end of shift summary log details of BANU: the reason and duration.
 
* Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook]
 
* Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook]
 
<!-- * Once a shift between the runs Restart FTT gas flow. Follow these steps:
 
<!-- * Once a shift between the runs Restart FTT gas flow. Follow these steps:
Line 318: Line 224:
 
'''Every Run:'''
 
'''Every Run:'''
  
'' Log screenshots of:''
+
'' Log screenshots of the following screens, and
 +
<font color="orange"> make sure at the moment you capture the screen the beam is ON </font> ''
 
* main scaler GUI display
 
* main scaler GUI display
 
* Detector occupancy plots
 
* Detector occupancy plots
* Trigger rate gui
+
* Trigger rate GUI
 +
* Roc Rates (MB/s) GUI
 
* Beam strip charts
 
* Beam strip charts
* FTCalo FADC scalers
+
* FT-Cal FADC scalers
  
 
|}
 
|}

Revision as of 12:56, 20 November 2018

[edit]

If calling local numbers (with area code prefix 757) from the counting room dial 9+[last 7 digits]. To call other area codes dial 91+[10 digit number]

Role Phone Number
Hall B Run Coordinator (757) 575-7540 (cell)
Hall B Physics Division Liaison (757) 876-1789 (cell)
MCC 7048
Crew Chief 7045
Crew Chief (757) 876-3367 (cell)
Program Deputy (757) 876-7997 (cell)
RadCon (757) 876-1743 (cell)
Gate House Guard 5822
Location Phone Number
Hall B Floor 5165
Hall B Space Frame 5170 and 5171
Hall B Forward Carriage 5371
Hall B Gas Shed 7115
Hall B Counting House 5244 (Shift Expert)
Hall B Counting House (757) 329-4846 (Shift Expert cell)
Hall B Counting House 5245 or 5126 (Shift Worker)
Hall A Counting House 5501
Hall C Counting House 6000
Hall D Counting House 5504
Hall B System Phone Number On-Call Person
Engineering (757) 748-5048 (cell)
(757) 897-9060 (cell)
Engineering On-Call (primary)
Denny Insley (secondary)
Slow Controls (757) 748-6922 (cell) Nathan Baltzell
Beamline (757) 303-3996 (cell) Eugene Pasyuk
DC (757) 218-4372 (cell)
(757) 748-5048 (cell)
Florian Hauenstein (primary)
Engineering On-Call (secondary)
SVT/MVT/MM (757) 541-7539 (cell)
(757) 753-7769 (cell)
Yuri Gotra (primary)
Rafo Paremuzyan (secondary)
ECAL (757) 810-1489 (cell) Cole Smith
FTOF/CTOF (757) 344-7204 (cell) Daniel Carman
CND (757) 329-4844 (cell) Pierre Chatagnon
HTCC/LTCC (757) 344-7174 (cell) Youri Sharabian
FT (757) 344-1848 (cell) Raffaella De Vita
BAND (757) 310-7198 (cell) Florian Hauenstein
RICH (757) 344-3235 (cell)
(757) 748-6922 (cell)
Valery Kubarovsky (primary)
Nathan Baltzell (secondary)
DAQ (757) 232-6221 (cell) Sergey Boiarinov
Cryotarget (757) 218-2266 (cell)
(757) 871-5374 (cell)
(757) 897-1415 (cell)
(757) 746-9277 (cell)
Xiangdong Wei (first)
James Brock (second)
James Maxwell (third)
Chris Keith (fourth)
RG-E Solid Target (757) 344-1848 (cell) Antonio Radic
Authorized Hall B Solenoid/Torus Operators
Hall B Denny Insley, Morgan Cook, Eugene Pasyuk
Magnet Group Probir Ghosha, Renuka Rajput-Ghoshal
Detector Support Group Brian Eng, Pablo Campero, Tyler Lemon
DC Power Onish Kumar, Sarin Philip
  • Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
  • To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
  • Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.

Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.


CLAS12 Run Group K, Fall 2018
Beam energy 10.6 GeV (5 pass)
Important: Document all your work in the logbook!
Remember to fill in the run list at the beginning and end of each run (clas12run@gmail.com can fill the run list)

RC: Annalisa D'Angelo

PDL: Eugene Pasyuk


  • Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.

The integrated rates on the upstream counters have to be in the range 0-15 Hz (rates up 100 Hz are acceptable) and the rates on the midstream counters have to be in the range 10-20 Hz (acceptable up to 50 Hz) @50 nA. Counting rates in the range of hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.

  • Note 2: At the end of each run, follow the standard DAQ restart sequence

"end run", "cancel", "reset", then if the run ended correctly, "download", "prestart", "go". If the run did not end correctly or if any ROCs had to be rebooted, "configure", "download", "prestart", "go".

After each step, make sure it is complete in the Run Control message window. If a ROC has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.

  • Note 3: Nominal beam positions: 2C24A (X=0.2 mm, Y=0.2 mm) , 2H01 (X=0.3 mm, Y=-0.9 mm)
  • Note 4: Do not turn OFF FTOF HVs, even during the beam tune with CW beam (turn off when doing a Moller run or if there is tuned/pulsed beam in the upstream beamline)
  • Note 5: In case of a Torus and/or Solenoid Fast Dump do the following:
    1. Notify MCC to request beam OFF and to drop Hall B status to Power Permit
    2. Call Engineering on-call
    3. Make separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Ruben Fair, Probir Goshal, Dave Kashy and esr-users@jlab.org
    4. Notify Run Coordinator
    5. Turn off all detectors
  • Note 6: When beam is being delivered to the Faraday Cup:
    1. the Fast Shut Down elements: Upstream, Midstream, Downstream, BOM, and Solenoid should always be in the state UNMASKED
    2. No changes to the FSD threshold should be made without RC or beamline expert approval
  • Note 7: Any request for a special run or change of configuration has to be approved by the RC & documented
  • Note 8: Carefully check the BTA every hour and run the script btaGet.py to print for you what HAS TO BE in BTA for this hour. Edit BTA if it is incorrect.
  • Note 9: Reset CLAS12MON frequently to avoid histogram saturation.
  • Note 11 Do not Turn OFF MVT HV: Instead go to 'Restore settings' from the MVT overview screen:
    1. SafeMode.snp for beam tuning and Moeller runs
    2. MV_HV_FullField.snp for full solenoid field
    3. MV_HV_MidField.snp wgeb solenoid < 4T

  • NOTE 12 Check the vacuum periodically, make sure vacuum id not higher than 5e-5
  • NOTE 13 Always reset the CFD threshold after all power off/on on the CFD crate

After the CAMAC crate 1 holding the CND CFD boards is switched off for any reason, it is mandatory to reset the associated thesholds typing the following command from any clon machine terminal:

>> $CODA/src/rol/Linux_x86_64/bin/cnd_cfd_thresh -w 0
  • NOTE 14: As of 10/25, the issue of detector scalers being frozen and starting a new run has been resolved. Shift workers should anyway check routinely scalers to verify they update correctly and make a logbook entry if anomalies are observed after starting a new run.

(Updated: Nov. 20, 2018 at 11:50>/i>

  • Before beam delivery ramp torus to -3770 A (100% field - negatives outbending) and solenoid to 2416 A (100% field); empty target and turn all detectors off
  • Tune beam in upstream beamline following nominal procedures
  • Take Moller run
  • Tune 5 nA beam to Faraday Cup following nominal procedures
  • Ensure the beam position at the target is optimized for minimal rates
  • Take 2 hr empty target run (beam current TBD)
  • Begin to optimize DAQ and trigger setup
  • Turn beam off and fill target
  • Take 2 hr run with 5 nA
  • Complete initial trigger studies
  • Production with configuration PROD66 and trigger_v23.trg at 30 nA.
  • Any questions or uncertainty about what to do please call RC

Make sure to save ROC Rates (MB/s) GUI to logbook for each run together with beam screens and trigger GUI

  • Make sure that the FSD thresholds are set correctly and they are unmask when ready to receive beam to the FC @50 nA
    • Upstream 2000
    • Midstream 1000
    • Downstream 900000
    • BOM 15000
    • Dwell time 5 ms

Shift Worker Notes:

  • If the machine is down for more than 30 min ask for low current first 5 nA ,make sure that the beam is stable both in position and current, check that the rates are OK on all the detectors and halo counters. Then ask for 45 nA and continue data for production. If there are issues with the beam call RC. Sometimes MCC operator may ask to deliver tuned mode beam --- do not accept it. We need CW beam sent to the Faraday cup. If there is indeed a need for tuned beam, it should be sent to the tagger dump with the tagger magnet on. If you are uncertain, please call RC/PDL.
  • For RICH recovery procedures, please see Log entry https://logbooks.jlab.org/entry/3562273. This would apply in the cases of 1. DAQ crash: rich4 is not responding or 2. RICH alarms (LV,missing tile, temperature etc). If it does not work or you are uncertain about what to do, contact the RICH expert on call.

In case of other questions or uncertainties of what to do, call the RC


General Instructions:

  • For a given beam current, compute the FSD thresholds according to the Establish Physics Quality Beam document. Call MCC to update the values. Contact the beamline expert if there are questions about setting the FSD thresholds.
  • The main lights in the Hall (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during an access, they should be switched off when leaving the Hall. Note that the dome lights when switched off cannot be turned back on immediately because they require 10-15 min to cooldown.
  • Do not run more than 60 minutes above 30 nA with 5-pass beam without the beam blocker in front of Faraday cup. Put beam blocker in for long running at high currents for 5 pass operations.
  • Turn DC HV off only for beam tuning; if no beam is available or when beam is stable, keep them on even if you are not taking data.
  • In case of loss of communication with IOCBTARG, follow instructions at https://logbooks.jlab.org/entry/3502218
  • With any issue contact On-Call Experts or RC - do not spend more than 15-20 min trying to fix the problem.
  • Check that no unnecessary beamline-related screens are open. This includes particularly the big beamline overview screen, but also and any motor/harp/collimator screens, and ioc health screens.
  • Reference harp scans: 2C21, 2C24, 2H01

Every Shift:

  • Follow run plan as outlined by RC
  • If any concern about beam stability, ask MCC if orbit locks are on (they should be).
  • Keep shift summary up to date in HBLOG. Record all that happens.
  • Check on white board all scalers, strip charts and monitoring plots that need to be logged regularly
  • Document any beam condition change and send scaler GUIs to HBLOG
  • Fill out BTA hourly. Click "Load from EPICS" to automatically fill the left side.
  • When you do BTA keep track of of BANU. Include at the end of shift summary log details of BANU: the reason and duration.
  • Fill and submit the shift checklist in the logbook

Every Run:

Log screenshots of the following screens, and make sure at the moment you capture the screen the beam is ON

  • main scaler GUI display
  • Detector occupancy plots
  • Trigger rate GUI
  • Roc Rates (MB/s) GUI
  • Beam strip charts
  • FT-Cal FADC scalers


Clas12design.png