Difference between revisions of "AI For Experimental Controls"
Jump to navigation
Jump to search
Line 9: | Line 9: | ||
* [https://www.sciencedirect.com/science/article/abs/pii/S0168900220312043 GlueX beamline & detector NIM paper] | * [https://www.sciencedirect.com/science/article/abs/pii/S0168900220312043 GlueX beamline & detector NIM paper] | ||
* [https://www.sciencedirect.com/science/article/pii/S0168900220302771 CDC NIM paper] | * [https://www.sciencedirect.com/science/article/pii/S0168900220302771 CDC NIM paper] | ||
− | * [https://halldweb.jlab.org/DocDB/0048/004800/ | + | * [https://halldweb.jlab.org/DocDB/0048/004800/002/CDC_calibrations.pdf CDC calibrations and CCDB tables] |
* [https://halldweb.jlab.org/wiki/index.php/Getting_Started_At_GlueX#Software Getting started with GlueX software] | * [https://halldweb.jlab.org/wiki/index.php/Getting_Started_At_GlueX#Software Getting started with GlueX software] | ||
* [https://halldweb.jlab.org/cgi-bin/ccdb/objects Calibration const database CCDB browser] [https://github.com/JeffersonLab/ccdb/wiki/CCDB-CLI CCDB wiki on CLI] | * [https://halldweb.jlab.org/cgi-bin/ccdb/objects Calibration const database CCDB browser] [https://github.com/JeffersonLab/ccdb/wiki/CCDB-CLI CCDB wiki on CLI] |
Revision as of 03:07, 4 April 2021
Documentation
Resources
- Intro to GlueX - links to videos
- GlueX beamline & detector NIM paper
- CDC NIM paper
- CDC calibrations and CCDB tables
- Getting started with GlueX software
- Calibration const database CCDB browser CCDB wiki on CLI
- Run conditions database RCDB browser example search query
Useful logbook entries
- Pressure calibration (uncalibrated mean is ~100 kPa)
- gain const fit attempt summer 2020
- gain const fit attempt Jan 2020
- occupancy plot connector map
Raw data files
/cache/halld/RunPeriod-2018-08/rawdata/Run051051/hd_rawdata_051051_001.evio fall 2018 production, 180nA, 100kPa
source /group/halld/Software/build_scripts/gluex_env_boot_jlab.csh hd_root /cache/halld/RunPeriod-2018-08/rawdata/Run051051/hd_rawdata_051051_001.evio -PPLUGINS=CDC_dedx,CDC_amp,CDC_TimeToDistance -PEVENTS_TO_KEEP=10000 -o outputfile.root
Add to resources
- EPICS documentation & tools names whatever replaced myaviewer, myaplot
- List of EPICS vars eg
IBCAD00CRCUR6 Hall D beam current RESET:i:GasPanelBarPress1 atmospheric pressure uncalibrated GAS:i::CDC_Temps-CDC_D1_Temp
many shown on https://logbooks.jlab.org/entry/3861759
Where's Naomi's list of particularly useful runs?