== When hall reaches "Beam Permit", turn on the chicane ([https://wiki.jlab.org/hps-run/images/c/cd/Chicane_controls.pdf])
 
== Establish beam to the tagger dump (see "General instruction" on the right) ==
 
== Establish beam to the tagger dump (see "General instruction" on the right) ==
 
# Take a screenshot of the ECal scaler for reference when beam is established at the tagger
 
# Take a screenshot of the ECal scaler for reference when beam is established at the tagger

Revision as of 16:29, 2 March 2016


[edit]
HPS 2016 run, February 4 to March 14, weekends only.
Shifts are manned from Friday 3pm to 7am on Monday.
Beam energy 2.3 GeV (1 pass).
Important: Document all your work in the logbook!

RC: Nathan Baltzell (Bluejeans info for Run Meetings on Thursdays and Fridays at 2pm)

  • (757) 575-7540
  • 9 575 7540 from Counting Room

PDL: Harut Avakian

Run Plan for February 26 - 29, 2016:

Start close-up of the Hall at 3pm on Friday, March 4 (see "General instruction" on the right)

== When hall reaches "Beam Permit", turn on the chicane ([1])

Establish beam to the tagger dump (see "General instruction" on the right)

  1. Take a screenshot of the ECal scaler for reference when beam is established at the tagger

Bring beam to FC:

  1. Note: in order to have reliable readings on two important for HPS BPMs, 2H00 and 2H02, beam current should be 50 nA. Before moving forward with 2H02A harp scans and beam profile tune, make sure orbit lock is engaged at positions on 2H00(X=0.00,Y=0.00) and on 2H02(X=-1.00,Y=-0.85).
  2. Important Note: Before bringing beams to the FC, be sure that the SVT and ECal are off, the SVT fully retracted, the target out, and the 2.82 mm SVT collimator is in. All beam studies should be done in these conditions with beam currents of 50 nA.
  3. The required beam profile at 2H02A harp is: X-width <~0.25 mm, Y-width <~ 0.10 mm, and the tilt angle <15 degrees. The spot on the Chromax viewer should be close to x=-2mm, y=-5mm. Do not waste too much time on the initial beam tune, as long as rates on the halo counters are low - Downstream L/R/T/B and HPS-L/R <~few Hz/nA, and HP-SC < few x 10 Hz, the following program still can be done:
  4. Set beam position
    • Have MCC move beam to standard values (see "General instructions" on the right)
    • Perform a SVT wire scan
    • Ask for the beam to be moved up by 100um at 2H02
    • Repeat and record 2H02 harp scan, SVT wire scan and BPM values.
    • Scan of the 2.82 mm collimator and re-center it. Record the new position have it entered into the epics data base.See https://logbooks.jlab.org/entry/3379405
  5. Restore ECal and Trigger
    • Turn on ECal
    • Record FADC rates with and without the 4 um target at 200 nA. Agree with last weekend? See https://logbooks.jlab.org/entry/3379417
    • Trigger/DAQ expert checks trigger rates, DAQ, and deadtime with 200 nA beam on 4 um target. Record:
      1. main scaler screen
      2. ecal scaler gui
      3. trigger rate gui (requires DAQ Prestarted with HPS/Run2016/v7_200nA.trg)
  6. SVT Setting (call SVT expert in)
    • If beams are stable, SVT expert moves SVT to 1.0 and then 0.5 mm
    • record occupancy, latency, data size, and deadtimes
  7. Record Data with 4um target
    • Use v7_200nAtrig.
    • Save scalers, trigger gui, FADC display gui each run.
    • Be sure to follow General Guidelines, especially Every Shift and Every Run.
    • Do one 2H02 harp scan per shift;
    • Fill out BTA;
    • Monitor and record BPM 2H02 history carefully to insure stable beams.
    • If beams are not stable, get MCC to fix it!
    • After each run execute this script (replace RunNb by the actual run number):
      • ssh hpsrun@clondaq5
      • > hps2tape.sh RunNb
  8. Beam current scan (to be scheduled by RC)
    • Take data at various currents: 50nA, 100nA, 250nA, 300nA ...


Miscellaneous Notes:

  1. Do not run more than 60 minutes above 30 nA without the beam blocker in front of Faraday cup. Put beam blocker in for long running at high currents.


General Instructions:

Locking up the hall on Fridays

  • At 2pm check the status of the activities in the hall and notify RC if there are potential delays for the lockup at 3pm.
  • Work with the hall work coordinator (Doug Tilles or his designee) to make sure hall is ready for sweep at around 3pm: vacuum is good, magnet power supplies are turned ON and on remote, LCW is on.
  • Make sure experts, beamline, ECal, SVT, and slow controls, checked their systems before the lockup.
  • When ready notify MCC to start sweep and lockup of the hall.
  • Make sure all necessary monitoring GUIs are up and running.
  • Make sure beam viewer screens are up.

Acceptable Beam Conditions:

  1. To establish good beam conditions:
    • Make sure SVT is retracted and both SVT and ECAL are OFF.
    • First send beam to the tagger dump (ask MCC to turn ON the tagger magnet).
    • Check that beam type is "Photon" on the BTA GUI (can be opened from "Beam" GUI).
    • Check the beam position on the tagger viewer, it should be approximately in the centre of the screen
    • Follow instructions under "Procedures" on the documentation tab for "Beamline"[2]. To tune the beam on tagger dump and perform harp scans beam current should be <10 nA.
    • Check profile using 2C21 and tagger harp scans, and compare the positions and widths with previous scans ([3],[4]). Positions on both harps should be with +/- 1mm, widths on 2C21 should be <~0.1+/-0.05 mm, and on the tagger harp (2C24) <~0.35 +/- 0.1mm.
    • Halo counters UPS-L/R and TAG-L/T/T2 should be ~few Hz/nA [5]
  2. Before sending beam to the Faraday cup
    • Check that SVT protection collimator is ON
    • HPS target is OUT
    • SVT is OUT (position 0 mm) and voltages are OFF
    • ECal HV is OFF
  3. Send beam to the Faraday cup
    • Follow the instructions under "Procedures" on the documentation tab for "Beamline"[6] to establish beam to the electron dump. Note: in order to have reliable readings on two important for HPS BPMs, 2H00 and 2H02, beam current should be 50 nA.
    • Ask MCC to establish 50 nA beam with HPS orbit locks on (We need HallBHPSOrb not HallBOrb configuration). For orbit lock positions on 2H00(X=0.00,Y=0.00) and on 2H02(X=-1.00,Y=-0.85). Use the 2.82 mm SVT collimator. .
    • Tune beam profile at HPS using measured widths on 2H02A harp. The required beam profile at 2H02A harp is: X-width <~0.25 mm, Y-width <~ 0.10 mm for commissioning, and Y-width ,~ 0.05 for physics running, and the tilt angle <15 degrees.
    • Check the beam spot on chromax viewer
    • The halo counter rates before HPS must be low:
      1. UPS-L and UPS-R few Hz/nA,
      2. The tagger counters should count less than Hz/nA and downstream counters should count ~Hz/nA
      3. The halo counter rates on HPS, HPS-L/R/T/SC, depends on the collimator and HPS chicane settings, but should not be more than 100 Hz/nA [7]
    • Positions on BPMs must be close to what they were before [8]
    • Insert the 4um W target without turning off the beam.
  4. Before accepting beam, make sure all the previous conditions are met. Always read previous log entries, compare settings of BPMs and correctors with previous settings using scaler_hps GUI.

Recovering from beam trips when running SVT at 0.5 mm:

  1. SVT HV will trip off automatically
  2. Check the FSD GUI to see if high rates in the HPS halo counters generated the trip
    • If it was not an HPS halo counter trip, MCC will restore the beam as usual (following their own instructions). As soon beam is back and stable, restore SVT HV.
    • If it was an HPS halo counter trip, MCC will not restore the beam. Inform MCC that we will get back to them when we are ready for beam.
      1. Retract the SVT to its 1.5 mm stations, both top and bottom.
      2. Tell MCC we are ready for beam.
      3. Once beam is restored, confirm that both 2H02 beam positions x and y are as desired and halo counter rates are as expected.
      4. Once beam is stable for ~1 minute, restore SVT HV and the SVT to its nominal position.
      5. Resume data taking.

Every Shift:

  1. Follow run plan as outlined by RC
  2. If any concern about beam stability, ask MCC if orbit locks are on (they should be).
  3. Keep shift summary up to date in HBLOG. Record all that happens.
    • Check on white board all scalers, strip charts and monitoring plots that need to be logged regularly
    • Document any beam condition change and send scaler GUIs to HBLOG
    • Fill and submit the shift checklist in the logbook
  4. Perform 2H02A harp scan once per shift or when beam conditions have changed, based on beam monitors (BPMs, halo rates, beam-viewer)
  5. With any issue contact On-Call Experts or RC

Every Run:

  1. After "Prestart" but before "Go", Check ECal Latency
  2. After "Go": Check SVT Occupancy
  3. Update the run spreadsheet on Google Docs
  4. After each run execute this script (replace RunNb by the actual run number):
    • ssh hpsrun@clondaq5
    • > hps2tape.sh RunNb
  5. See the whiteboard for everything else that should be done on a per-run basis.

Setting up Chicane for E=2.3 GeV:

Note: This requires Beam Permit and NO beam to HPS / Faraday Cup.

  1. Turn on chicane power supplies following instructions on the Shift Documentation tab ([9])

SVT Instructions:

  1. Turn SVT completely OFF (Bias, FEB, Flange) when entering Beam Permit.
  2. Before sending beam to Faraday cup, verify (and page SVT expert if otherwise):
    • SVT should be open: "Position" at 0.000 mm in the main scaler_hps GUI
    • SVT HV is off: all red/green indicators RED in SVT bias GUI
  3. The first time sending beam to the Faraday cup after the hall is closed, page the SVT expert.

ECAL Instructions:

  • HV must be OFF during FIRST delivery of beam to the Faraday Cup after tuning to the Tagger Dump.
    • Only after stable beam established to Faraday Cup can HV can be turned ON.
  • HV should be OFF when running beam studies with Struck scalers with 1 mm wire or tuning collimator position.


Run Coordinator
Feb 3 - Feb 10 Stepan Stepanyan
Feb 10 - Feb 17 Takashi Maruyama
Feb 17 - Feb 24 John Jaros
Feb 24 - Mar 2 Raphaël Dupré
Mar 2 - Mar 9 Nathan Baltzell
Mar 9 - Mar 16 Maurik Holtrop
Physics Division Liaison
Feb 3 - Mar 16 Harut Avagyan
Beamline
Feb 4 - Feb 10 F.X. Girod
Feb 10 - Feb 17 Stepan Stepanyan
Feb 17 - Feb 24 Rafo Paremuzyan
Feb 24 - Mar 2 Clive Field
Mar 2 - Mar 9 Takashi Maruyama
Mar 9 - Mar 16 John Jaros
SlowControls
Feb 4 - Feb 11 Stepan Stepanyan
Feb 12 - Feb 18 Sho Uemura
Feb 19 - Feb 25 Bryan McKinnon
Feb 26 - Mar 10 Hovanes Egiyan
Mar 11 - Mar 14 Nathan Baltzell
ECAL
Feb 2 - Feb 9 Holly Vance
Feb 9 - Feb 16 Nathan Baltzell
Feb 16 - Feb 23 Raphaël Dupré
Feb 23 - Mar 1 Andrea Celentano
Mar 1 - Mar 8 Gabriel Charles
Mar 8 - Mar 15 Gabriel Charles
SVT
Feb 4 - Feb 12 Matt Graham
Feb 12 - Feb 19 Sho Uemura
Feb 19 - Feb 26 Matt Solt
Feb 26 - Mar 4 Vitaliy Fadeyev
Mar 4 - Mar 14 Tim Nelson
DAQ
Feb 3 - Mar 16 Sergey Boyarinov



Spring 2015 Final @ 1 GeV:

.

Charge.png


System/Person Pager/Phone Number
Run Coordinator (757) 575-7540 (cell)
Physics Div. Liaison (757) 876-1789 (cell)
MCC-OPS 7048
Crew Chief 7045
Crew Chief 9-879-3367 (cell)
Program Deputy 9-876-7997 (cell)
Gate House Guard 5822
DAQ/Online (757) 869-2188 (cell)
SVT (757) 541-7539 (cell)
ECAL (757) 810-1489 (cell)
Slow Controls (757) 748-6922 (cell)
Beamline (757) 303-3996 (cell)
Engineering (757) 748-5048
Hall-B Floor 5165
Hall-B Space Frame 5170, 5171
Hall-B Forward Carriage 5371
Hall-B Counting Room 5126, 5244, 5246, 5247
Hall-B Gas Shed 7115


Svtpic.png

Ecalpic.png