Cryo Xferline Oct 6, 2017

From LCLS-II testing
Revision as of 11:13, 9 October 2017 by Jordan (talk | contribs) (Created page with "LERF PIPING ARRANGEMENT Location: ted-2504@jlab.org Date: Oct 6, 2017 from 10:00 AM to 11:00 AM GMT -05:00 US/Canada Eastern Organizer: James Henry Attendees: Edward Daly gre...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

LERF PIPING ARRANGEMENT Location: ted-2504@jlab.org Date: Oct 6, 2017 from 10:00 AM to 11:00 AM GMT -05:00 US/Canada Eastern Organizer: James Henry Attendees: Edward Daly gregory Keith Harding Kevin Jordan

Key points:

  • Transfer line simplified that to K. Dixon inputs
  • While CHL line to LERF is warm valves should be leak checked
  • No 'clean' beam tube work is needed at transfer line end of module pair - no need for clean room
  • Center section (in between the two CMs) assembly was discussed. Beam tube first then cryo piping then shields. Center extension ring & 'big' bellows sequence discussed. May need trolly cart for shifting ring and bellows