* When adding more FADCs for the aerogel detector, double check for possible Base Address overlap. This may cause no visual error, but may increase the deadtime significantly due to bus error or even crash the VME crate. | * When adding more FADCs for the aerogel detector, double check for possible Base Address overlap. This may cause no visual error, but may increase the deadtime significantly due to bus error or even crash the VME crate. | ||
+ | * MLU was installed on 01/10/18 | ||
=== Left HRS === | === Left HRS === | ||
Line 32: | Line 33: | ||
| MLU || 1 || 0x0052 || -- || 0x00520000 | | MLU || 1 || 0x0052 || -- || 0x00520000 | ||
|} | |} | ||
+ | |||
+ | * MLU was installed on 01/10/18 |
Revision as of 09:08, 12 January 2018
VME addresses
Right HRS
Configuration valid starting from run 90465 (December 5, 2017):
Number of modules | Address 1st module | Address increment | Base Address | |
---|---|---|---|---|
FADC | 4 | 0xB01000 | 0xEA00 | 0x0A000000 |
F1-TDC | 2 | 0xB000 | 0x1000 | 0x08000000 |
VETROC | 1 | 0x980000 (19<<19) | -- | 0x0D8000000 |
MLU | 1 | 0x0053 | -- | 0x00530000 |
- When adding more FADCs for the aerogel detector, double check for possible Base Address overlap. This may cause no visual error, but may increase the deadtime significantly due to bus error or even crash the VME crate.
- MLU was installed on 01/10/18
Left HRS
Configuration valid starting from run 675 (December 5, 2017):
Number of modules | Address 1st module | Address increment | Base Address | |
---|---|---|---|---|
FADC | 4 | 0xA80000 | 0xEA00 | 0x0A000000 |
F1-TDC | 2 | 0xFF3000 | 0x1000 | 0x08000000 |
MLU | 1 | 0x0052 | -- | 0x00520000 |
- MLU was installed on 01/10/18