Revision as of 22:13, 30 November 2017

Optics Study Page (Back to Tritium-Main) Back to Commissioning Page

Run Info

LHRS optics runs

Step L1: Procedure with Sieve-slit

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Multi-foil carbon In Off 4.3 3.8 17
Multi-foil carbon In On 4.3 3.8 17
Multi-foil carbon Out On 4.3 3.8 17
Multi-foil carbon In Off 4.3 3.0 17
Multi-foil carbon In On 4.3 3.0 17
Multi-foil carbon Out On 4.3 3.0 17

Step L2: Delta Scan with Proton Elastic

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-4%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=0%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+4%;

RHRS optics runs

Step R1: Procedure with Sieve-slit

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Multi-foil carbon In Off 4.3 3.8 17
Multi-foil carbon In On 4.3 3.8 17
Multi-foil carbon Out On 4.3 3.8 17
Multi-foil carbon In Off 4.3 3.0 17
Multi-foil carbon In On 4.3 3.0 17
Multi-foil carbon Out On 4.3 3.0 17

Step R2: Delta Scan with Proton Elastic

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-4%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=0%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+4%;

Calibration