Difference between revisions of "Optics Calibration"

From Tritium Experiments Group
Jump to navigation Jump to search
 
(3 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
[https://wiki.jlab.org/tegwiki/index.php/Installation_and_Commissioning#Optics_commissioning_runs <b>Back to Commissioning Page</b>]
 
[https://wiki.jlab.org/tegwiki/index.php/Installation_and_Commissioning#Optics_commissioning_runs <b>Back to Commissioning Page</b>]
 
==Run Info==
 
==Run Info==
* With Raster '''On''', the Maximum Beam Current on Multi-Foils, I_max = 20uA
+
* With Raster '''Off''', the Maximum Beam Current on Multi-Foils, I_max = 10uA
* With Raster '''Off''', the Maximum Beam Current on Multi-Foils, I_max = 40uA
+
* With Raster '''ON''', the Maximum Beam Current on Multi-Foils, I_max = 40uA
 
=== LHRS optics runs===
 
=== LHRS optics runs===
 
==== <b>Step L1: Procedure with Sieve-slit</b>====
 
==== <b>Step L1: Procedure with Sieve-slit</b>====
Line 47: Line 47:
 
     <td> 3.8 </td>
 
     <td> 3.8 </td>
 
     <td> 17 </td>
 
     <td> 17 </td>
     <td> </td>
+
     <td> Taken during the Production-Run</td>
 
   </tr>
 
   </tr>
  
Line 80: Line 80:
 
     <td>3.0 </td>
 
     <td>3.0 </td>
 
     <td>17 </td>
 
     <td>17 </td>
     <td> </td>
+
     <td>May not take this </td>
 
   </tr>
 
   </tr>
 
</table>
 
</table>
Line 193: Line 193:
 
     <td> 3.8 </td>
 
     <td> 3.8 </td>
 
     <td> 17 </td>
 
     <td> 17 </td>
     <td> </td>
+
     <td>Taken during the Production-Run</td>
 
   </tr>
 
   </tr>
  
Line 215: Line 215:
 
     <td>3.0 </td>
 
     <td>3.0 </td>
 
     <td>17 </td>
 
     <td>17 </td>
     <td> </td>
+
     <td>May not take this run </td>
 
   </tr>
 
   </tr>
  
Line 226: Line 226:
 
     <td>3.0 </td>
 
     <td>3.0 </td>
 
     <td>17 </td>
 
     <td>17 </td>
     <td> </td>
+
     <td></td>
 
   </tr>
 
   </tr>
</table>  
+
</table>
+
 
 
==== <b>Step R2: Delta Scan with Proton Elastic </b>====
 
==== <b>Step R2: Delta Scan with Proton Elastic </b>====
 
* Note: Depending on the beam-time and quality, this run may be pushed to the Jan./2018 Runs.
 
* Note: Depending on the beam-time and quality, this run may be pushed to the Jan./2018 Runs.

Latest revision as of 11:40, 1 December 2017

Optics Study Page (Back to Tritium-Main) Back to Commissioning Page

Run Info

  • With Raster Off, the Maximum Beam Current on Multi-Foils, I_max = 10uA
  • With Raster ON, the Maximum Beam Current on Multi-Foils, I_max = 40uA

LHRS optics runs

Step L1: Procedure with Sieve-slit

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Multi-foil carbon In Off 4.3 3.8 17
Multi-foil carbon In On 4.3 3.8 17
Multi-foil carbon Out On 4.3 3.8 17 Taken during the Production-Run
Multi-foil carbon In Off 4.3 3.0 17
Multi-foil carbon In On 4.3 3.0 17
Multi-foil carbon Out On 4.3 3.0 17 May not take this

Step L2: Delta Scan with Proton Elastic

  • Note: Depending on the beam-time and quality, this run may be pushed to the Jan./2018 Runs.
Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
H2 Gas In 2 x 2 mm2 Delta scan ΔP=-4%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=-2%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=0%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=+2%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=+4%;

RHRS optics runs

Step R1: Procedure with Sieve-slit

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Multi-foil carbon In Off 4.3 3.8 17
Multi-foil carbon In On 4.3 3.8 17
Multi-foil carbon Out On 4.3 3.8 17 Taken during the Production-Run
Multi-foil carbon In Off 4.3 3.0 17
Multi-foil carbon In On 4.3 3.0 17 May not take this run
Multi-foil carbon Out On 4.3 3.0 17

Step R2: Delta Scan with Proton Elastic

  • Note: Depending on the beam-time and quality, this run may be pushed to the Jan./2018 Runs.
Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
H2 Gas In 2 x 2 mm2 Delta scan ΔP=-4%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=-2%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=0%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=+2%;
H2 Gas In 2 x 2 mm2 Delta scan ΔP=+4%;

Calibration