Line 3: Line 3:
 
:*"old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
 
:*"old" existing electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-3
 
:*"new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
 
:*"new" niobium electrode here : https://wiki.jlab.org/ciswiki/index.php/CIS-ASY-R28-1
* 4/8 Leak check good, cathode assembly going to S&A for fiducials
+
:: LgGnNb leak check => done 4/8, Carlos leak tested complete assembly in 1137
* 4/7 Walked S&A jobs w/ Chris, agreed to following:
+
:: S&A fiducialize =>
: S&A Gun-to-Y as found 4/9, tell us about Y ports, NEG tube and where cathode is pointing, no idea about anode
+
 
: We decide if we want to do/move anything and run beam again
+
 
: We decide when to vent HV and Depo, remembering to look for schneedle, clean out Ag flakes
+
* Alignment Jobs in Cave
 +
: Walk job with Carlos & Chris => done 4/7
 +
: S&A perform an as-found of the Gun through Y chamber => [[media:210414_UITF_15degLine_Summary.xlsx]]
 +
: Matt's "Have-Want" summary pics [[media:210414_HaveWant.pptx]]
 +
: Decide if we want to run beam before venting => don't think so, agree at 4/15 UITF meeting
 +
 
 
: S&A will fiducialize upstream anode face in UITF
 
: S&A will fiducialize upstream anode face in UITF
 
: S&A will be able to help us align new schneedle where cathode will go
 
: S&A will be able to help us align new schneedle where cathode will go

Revision as of 05:27, 14 April 2021

HV chamber : Replace cathode electrode

  • Electrodes
LgGnNb leak check => done 4/8, Carlos leak tested complete assembly in 1137
S&A fiducialize =>


  • Alignment Jobs in Cave
Walk job with Carlos & Chris => done 4/7
S&A perform an as-found of the Gun through Y chamber => media:210414_UITF_15degLine_Summary.xlsx
Matt's "Have-Want" summary pics media:210414_HaveWant.pptx
Decide if we want to run beam before venting => don't think so, agree at 4/15 UITF meeting
S&A will fiducialize upstream anode face in UITF
S&A will be able to help us align new schneedle where cathode will go
S&A will be able to align cathode to anode
S&A will be able to align cathode/anode combo on whatever line we want (thinking Y ports)
CIS follows up for puck in/out tests, and laser alignment

Depo chamber : Replace schneedle, fix pucks, opportunistic jobs

4/6 - Shop is fabricating two, trying to have one ready by 4/18
one from 316 or 316L SS and one from Nitronic 60 https://mis.jlab.org/mis/apps/job_request/mshop/view_request.cfm?request_id=330210&code=1
  • Nitronic 60 data sheet (Nitronic trademark AK Steel)
  • won't use this ... although probably not a problem, can be mildly magnetic Mir50 (Mir50 trademark ASC Steel)

Other jobs