Difference between revisions of "Bubble Chamber Meeting Wednesday January 20, 2016"
Jump to navigation
Jump to search
(22 intermediate revisions by the same user not shown) | |||
Line 4: | Line 4: | ||
Phone number: 1-888-240-2560 | Phone number: 1-888-240-2560 | ||
Meeting ID: 3528502673# | Meeting ID: 3528502673# | ||
− | |||
Meeting URL: http://bluejeans.com/3528502673 | Meeting URL: http://bluejeans.com/3528502673 | ||
Line 13: | Line 12: | ||
# Gamma Flux: [[media:G4Flux_Sept2015.pdf]] [[media:G4Flux_Sept2015.pptx]] | # Gamma Flux: [[media:G4Flux_Sept2015.pdf]] [[media:G4Flux_Sept2015.pptx]] | ||
# Expected Rates: | # Expected Rates: | ||
− | ## [[media:O18ga_rate_G4.txt]] | + | ## <sup>18</sup>O(γ,α)<sup>14</sup>C with no ThrCut: [[media:O18ga_rate_G4.txt]] |
− | ## [[media: | + | ## <sup>17</sup>O(γ,n)<sup>16</sup>O with: |
− | ## [[media: | + | ### ThrCut = 90 keV: [[media:O17gn_rate_G4_90keV.txt]] |
+ | ### ThrCut = 130 keV: [[media:O17gn_rate_G4_130keV.txt]] | ||
+ | ## <sup>14</sup>N(γ,p)<sup>13</sup>C with: | ||
+ | ### ThrCut = 20 keV: [[media:N14gp_rate_G4_20keV.txt]] | ||
+ | ### ThrCut = 50 keV: [[media:N14gp_rate_G4_50keV.txt]] | ||
− | |||
− | + | 2- Sept beam test data analysis: [[media:Analyses_Rashi_Jan2016.pdf]] [[media:Analyses_Rashi_Jan2016.pptx]] | |
− | + | 3- Discussion of June 2016 beam test | |
− | + | ||
+ | |||
+ | |||
+ | ---- | ||
+ | |||
+ | '''Notes from this meeting:''' | ||
+ | |||
+ | * In the simulation, the collimator inner radius is correct (8.0 mm). | ||
+ | |||
+ | * Bubble chamber simulation remaining tasks: | ||
+ | # Complete geometry: add stainless steel cube and flanges | ||
+ | # Add electron beam energy spread and beam size | ||
+ | # Measure fraction of photons that are absorbed in the N<sub>2</sub>O target as a function of E<sub>γ</sub> | ||
+ | |||
+ | * Next Bubble Chamber beam test will measure <sup>19</sup>F(γ,α)<sup>15</sup>N | ||
+ | |||
+ | * Old fluorine chamber has a height of 36 inches. Beamline height on the concrete platform is 27 inches. Beamline height before the platform is 42 inches. |
Latest revision as of 15:00, 24 January 2016
We will meet in TL 2221 on Wednesday January 20 at 3:30 pm EST.
For those calling in we'll use the Blue Jeans [1] audio conference system.
Phone number: 1-888-240-2560 Meeting ID: 3528502673# Meeting URL: http://bluejeans.com/3528502673
Agenda:
1- GEANT4 Simulation:
- Gamma Flux: media:G4Flux_Sept2015.pdf media:G4Flux_Sept2015.pptx
- Expected Rates:
- 18O(γ,α)14C with no ThrCut: media:O18ga_rate_G4.txt
- 17O(γ,n)16O with:
- ThrCut = 90 keV: media:O17gn_rate_G4_90keV.txt
- ThrCut = 130 keV: media:O17gn_rate_G4_130keV.txt
- 14N(γ,p)13C with:
- ThrCut = 20 keV: media:N14gp_rate_G4_20keV.txt
- ThrCut = 50 keV: media:N14gp_rate_G4_50keV.txt
2- Sept beam test data analysis: media:Analyses_Rashi_Jan2016.pdf media:Analyses_Rashi_Jan2016.pptx
3- Discussion of June 2016 beam test
Notes from this meeting:
- In the simulation, the collimator inner radius is correct (8.0 mm).
- Bubble chamber simulation remaining tasks:
- Complete geometry: add stainless steel cube and flanges
- Add electron beam energy spread and beam size
- Measure fraction of photons that are absorbed in the N2O target as a function of Eγ
- Next Bubble Chamber beam test will measure 19F(γ,α)15N
- Old fluorine chamber has a height of 36 inches. Beamline height on the concrete platform is 27 inches. Beamline height before the platform is 42 inches.