(45 intermediate revisions by 7 users not shown) |
Line 20: |
Line 20: |
| * [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf Torus] | | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf Torus] |
| * [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf Solenoid] | | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf Solenoid] |
− | * [https://docs.google.com/document/d/1kBNmLYg2gqa4XjWgMpbh0rBUxkSAupqdnMV4THepv7k/edit#heading=h.13kef88y2w8q Cryotarget] | + | <!--* [https://docs.google.com/document/d/1kBNmLYg2gqa4XjWgMpbh0rBUxkSAupqdnMV4THepv7k/edit#heading=h.13kef88y2w8q Cryotarget]--> |
− | * [https://github.com/HaykHakobyan/RGE-Target/blob/main/RG-E-expert-brief-manual.pdf RG-E Double Target] | + | * [https://wiki.jlab.org/clas12-run/images/4/49/Hall_B_Cryotarget_Controls_Manual_and_RGE_Solid_Target.pdf Cryotarget & RG-E Solid-foil Assembly] |
| * [https://github.com/JeffersonLab/clas12-manuals/raw/master/daq/opman_master.pdf DAQ] | | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/daq/opman_master.pdf DAQ] |
| * [[Media:clas12controls_shift.pdf|Slow Controls]] | | * [[Media:clas12controls_shift.pdf|Slow Controls]] |
Line 73: |
Line 73: |
| | | |
| 1. Double Target system alignment with all solid targets successively on beam position: app. 12 hrs --> | | 1. Double Target system alignment with all solid targets successively on beam position: app. 12 hrs --> |
− |
| |
− | <!--####################################### General ########################################-->
| |
− | = General =
| |
− |
| |
− | {| {{TableStyle1}}
| |
− |
| |
− | | valign=top |
| |
− | ==General==
| |
− | ===[https://logbooks.jlab.org/book/hallb Logbook]===
| |
− | ===[http://www.jlab.org/Hall-B/shifts Shift Schedule]===
| |
− | ===[https://docs.google.com/spreadsheets/d/1p_NaWUtR5q7lrO3np076EcClwUNqVzb2NymTndiqI8k/edit?usp=sharing Run Coordinator Schedule]===
| |
− | ===[https://www.jlab.org/Hall-B/run-web/rgk/ESAD_HallB-CLAS12_rgK.pdf ESAD], [https://www.jlab.org/Hall-B/run-web/rgk/COO_HallB-CLAS12_RGK.pdf COO], [https://www.jlab.org/Hall-B/run-web/rgk/RSAD_HallB-CLAS12_rgk.pdf RSAD]===
| |
− | ===[https://logbooks.jlab.org/checklists/151 Shift Checklist] ===
| |
− | ===[https://ace.jlab.org/btm/timesheet/eb Beam Time Accounting]===
| |
− | * '''[https://ace.jlab.org/cdn/doc/btm/userguide.pdf Beam Time Accounting User Guide]'''.
| |
− | ===[https://accweb.acc.jlab.org/hco/readiness Hot Checkout]===
| |
− |
| |
− | | valign=top |
| |
− | ==Manuals==
| |
− | =====Systems=====
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/beamline/manual/beamline_manual.pdf Beamline]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf Torus]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/torus/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf Solenoid]
| |
− | * [https://docs.google.com/document/d/1kBNmLYg2gqa4XjWgMpbh0rBUxkSAupqdnMV4THepv7k/edit#heading=h.13kef88y2w8q Cryotarget]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/daq/opman_master.pdf DAQ]
| |
− | * [[Media:clas12controls_shift.pdf|Slow Controls]]
| |
− | =====Detectors=====
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/blob/master/dc/Drift-chamber-operating-procedure.pdf DC]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/ftof/ftof_manual.pdf FTOF]
| |
− | * [https://clasweb.jlab.org/wiki/images/a/a2/Ec_manual.pdf ECAL]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/blob/master/ltcc/manual/ltcc_manual.pdf LTCC]
| |
− | * [https://clasweb.jlab.org/wiki/images/f/f1/HTCC_MANUAL.pdf HTCC]
| |
− | * RICH: [https://github.com/JeffersonLab/clas12-manuals/raw/master/rich/RICH_Manual.pdf Expert] [https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf Shift]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/ctof/ctof_manual.pdf CTOF]
| |
− | * [https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf CND]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/blob/master/svt/svt_operation_manual.pdf SVT]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/blob/master/mm/Documentation_Shifters_MVT.pdf MVT] and its [https://wiki.jlab.org/clas12-run/images/b/bf/MVT_for_Dummies.pdf Turn-on procedure]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/blob/master/ft/FT-Manual.pdf FT]
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/band/band_om.pdf BAND]
| |
− |
| |
− | =====Software=====
| |
− | * [https://wiki.jlab.org/clas12-run/images/c/c9/CedManual.pdf CED]
| |
− | * [https://wiki.jlab.org/clas12-run/images/f/fd/CLAS12Mon_documentation.pdf mon12]
| |
− |
| |
− | | valign=top |
| |
− | ==Procedures==
| |
− | * [https://github.com/JeffersonLab/clas12-manuals/raw/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]
| |
− | * [[Media:clas12moller.pdf|Performing Møller Runs]]
| |
− | * [[Media:HarpScanManual.pdf|Performing Harp Scans]]
| |
− | * [https://wiki.jlab.org/hps-run/images/0/0c/Accessing_the_tunnel.pdf Accessing the Tunnel/Hall]
| |
− |
| |
− | ==Logbooks==
| |
− | <font size=3>
| |
− | * [https://logbooks.jlab.org/book/elog MCC]
| |
− | * [https://logbooks.jlab.org/book/halog Hall-A]
| |
− | * [https://logbooks.jlab.org/book/hblog Hall-B]
| |
− | * [https://logbooks.jlab.org/book/hclog Hall-C]
| |
− | * [https://logbooks.jlab.org/book/hdlog Hall-D]
| |
− | </font>
| |
− |
| |
− | |}
| |
− |
| |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− |
| |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− |
| |
− | == '''Recent Changes''' ==
| |
− |
| |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− |
| |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− |
| |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− |
| |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− |
| |
− | == '''Current Issues''' ==
| |
− |
| |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− |
| |
− | === Beamline ===
| |
− |
| |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− |
| |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− |
| |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− |
| |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− |
| |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− |
| |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− |
| |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− |
| |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− |
| |
− | == '''Beam Restoration''' ==
| |
− |
| |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− |
| |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− |
| |
− | === Restoring Beam after Short Downtime ===
| |
− |
| |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− |
| |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− |
| |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− |
| |
− | * If good, log the new scan results.
| |
− |
| |
− | === Møller run ===
| |
− |
| |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− |
| |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− |
| |
− | === Beam Tuning to Faraday Cup ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− |
| |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron
| |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− |
| |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− |
| |
− |
| |
− |
| |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− |
| |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− |
| |
− | == '''Recent Changes''' ==
| |
− |
| |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− |
| |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− |
| |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− |
| |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− |
| |
− | == '''Current Issues''' ==
| |
− |
| |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− |
| |
− | === Beamline ===
| |
− |
| |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− |
| |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− |
| |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− |
| |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− |
| |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− |
| |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− |
| |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− |
| |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− |
| |
− | == '''Beam Restoration''' ==
| |
− |
| |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− |
| |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− |
| |
− | === Restoring Beam after Short Downtime ===
| |
− |
| |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− |
| |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− |
| |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− |
| |
− | * If good, log the new scan results.
| |
− |
| |
− | === Møller run ===
| |
− |
| |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− |
| |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− |
| |
− | === Beam Tuning to Faraday Cup ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− |
| |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron
| |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− |
| |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− |
| |
− |
| |
− |
| |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− |
| |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− |
| |
− | == '''Recent Changes''' ==
| |
− |
| |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− |
| |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− |
| |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− |
| |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− |
| |
− | == '''Current Issues''' ==
| |
− |
| |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− |
| |
− | === Beamline ===
| |
− |
| |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− |
| |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− |
| |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− |
| |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− |
| |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− |
| |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− |
| |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− |
| |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− |
| |
− | == '''Beam Restoration''' ==
| |
− |
| |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− |
| |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− |
| |
− | === Restoring Beam after Short Downtime ===
| |
− |
| |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− |
| |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− |
| |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− |
| |
− | * If good, log the new scan results.
| |
− |
| |
− | === Møller run ===
| |
− |
| |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− |
| |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− |
| |
− | === Beam Tuning to Faraday Cup ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− |
| |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron
| |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− |
| |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− |
| |
− |
| |
− |
| |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− |
| |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− |
| |
− | == '''Recent Changes''' ==
| |
− |
| |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− |
| |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− |
| |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− |
| |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− |
| |
− | == '''Current Issues''' ==
| |
− |
| |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− |
| |
− | === Beamline ===
| |
− |
| |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− |
| |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− |
| |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− |
| |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− |
| |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− |
| |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− |
| |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− |
| |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− |
| |
− | == '''Beam Restoration''' ==
| |
− |
| |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− |
| |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− |
| |
− | === Restoring Beam after Short Downtime ===
| |
− |
| |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− |
| |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− |
| |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− |
| |
− | * If good, log the new scan results.
| |
− |
| |
− | === Møller run ===
| |
− |
| |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− |
| |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− |
| |
− | === Beam Tuning to Faraday Cup ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− |
| |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron
| |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− |
| |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− |
| |
− |
| |
− |
| |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− |
| |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− |
| |
− | == '''Recent Changes''' ==
| |
− |
| |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− |
| |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− |
| |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− |
| |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− |
| |
− | == '''Current Issues''' ==
| |
− |
| |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− |
| |
− | === Beamline ===
| |
− |
| |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− |
| |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− |
| |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− |
| |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− |
| |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− |
| |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− |
| |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− |
| |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− |
| |
− | == '''Beam Restoration''' ==
| |
− |
| |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− |
| |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− |
| |
− | === Restoring Beam after Short Downtime ===
| |
− |
| |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− |
| |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− |
| |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− |
| |
− | * If good, log the new scan results.
| |
− |
| |
− | === Møller run ===
| |
− |
| |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− |
| |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− |
| |
− | === Beam Tuning to Faraday Cup ===
| |
− |
| |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− |
| |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− |
| |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− |
| |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron
| |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− |
| |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− |
| |
− |
| |
| | | |
| <!--####################################### GENERAL INFORMATION #############################################--> | | <!--####################################### GENERAL INFORMATION #############################################--> |
Line 991: |
Line 85: |
| | | |
| === New '''MVT LV''' Reboot Procedure === | | === New '''MVT LV''' Reboot Procedure === |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only. | + | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT experts only. |
| * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black; | | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black; |
| * '''Wait 20 seconds''', then '''turn LV back from the same menu'''. | | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''. |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON. | + | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates"; the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 minutes after LV is turned back ON. |
| * Reboot mvt1, mvt2, and mvt3 ROCS. | | * Reboot mvt1, mvt2, and mvt3 ROCS. |
| * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go). | | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go). |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''. | + | * '''If we have a beam and a reboot process takes more than 5 minutes, call the DAQ or MVT expert'''. |
| | | |
| === RICH issues === | | === RICH issues === |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure]. | + | * The RICH fibers alarm leads to web guidance, aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure]. |
| * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf''' | | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf''' |
| * See below for current issues | | * See below for current issues |
Line 1,006: |
Line 100: |
| === Rapid/Controlled Access to the Hall === | | === Rapid/Controlled Access to the Hall === |
| * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon. | | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon. |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House. | + | * After a higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House. |
| | | |
| === 24/7 ZOOM connection for Counting House === | | === 24/7 ZOOM connection for Counting House === |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker" | + | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], which is included in "Remote Shifts" in the "{{#switchtablink:Shift_Worker|Shift Worker}}" tab. |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,. | + | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows. |
− | * Enter the passcode from the logbook entry in tab "Shift Worker" | + | * Enter the passcode from the logbook entry in "{{#switchtablink:Shift_Worker|Shift Worker}}" tab. |
| | | |
| == '''Current Issues''' == | | == '''Current Issues''' == |
| | | |
| === Lights in the Hall === | | === Lights in the Hall === |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''. | + | * The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks from some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''. |
| * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731] | | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731] |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460 | + | * We have a '''new dome light switch outside the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460 |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down. | + | * When the dome lights are switched off, they cannot be turned back on immediately; they require 10-15 min to cool down. |
| | | |
| === Beamline === | | === Beamline === |
| | | |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running"). | + | * Orbit locks are on BPMs '''2C24A and 2H01''', which should generally be on ("Running"). |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| + | :- Beam positions at 2C24A and 2H01 must be kept within ±0.1 mm at the nominal beam positions listed under "References" at the {{#switchtablink:Short_Term_Schedule|Short Term Schedule}} tab. |
| * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy. | | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy. |
| ** The beam position at 2C21A is important for initial beam tuning (on tagger dump). | | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump). |
| *'''After the HWP change''' | | *'''After the HWP change''' |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| + | :- The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert. |
| ** Start a new run | | ** Start a new run |
| * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall. | | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall. |
Line 1,036: |
Line 130: |
| * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance. | | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance. |
| * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview | | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview | + | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset= 0 V) - appears blue in MVT overview |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview | + | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset= 0 V) - appears blue in MVT overview |
| + | * <font color=red>'''As of 05/10/24: BMT HV S2/3 L4/5 strip frequent trips'''</font>: The HV, Vset, was lowered by 10 V until it calmed down. If the problem persists, reduce the HV VSet value by an increment of 10 V after clicking the '''"Expert" button'''. Then, make a logbook entry and CC MVT/SVT/MM experts on it. |
| + | * If FMT gas errors appear, please follow the instructions in [https://logbooks.jlab.org/entry/4286305] |
| | | |
| === CND === | | === CND === |
| * CAMAC crate alarm: | | * CAMAC crate alarm: |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| + | :- CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, which can be done via the alarm handler. |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| + | :- After reboot, the CFD thresholds need to be set by running a script; see page 12 in the CND manual at the "General" tab: https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf |
| | | |
| === DAQ === | | === DAQ === |
| * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected! | | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected! |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate. | + | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u>, Prestart, Go. This will ensure proper compression of the FADCs and, therefore, a smaller data rate. |
| * roc reboot instructions: | | * roc reboot instructions: |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| + | :- To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1 |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| + | :- To check that the crate is back alive, type:clasrun> ping adcecal1 |
− | ** The ping will start to answer as soon as the crate communicates again.
| + | :- The ping will start to answer as soon as the crate communicates again. |
| | | |
| === DC === | | === DC === |
Line 1,056: |
Line 152: |
| | | |
| === ECAL/PCAL === | | === ECAL/PCAL === |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957 | + | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957 |
| * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400 | | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400 |
| | | |
Line 1,065: |
Line 161: |
| === RICH === | | === RICH === |
| * '''Known problematic PMTs and tile''': | | * '''Known problematic PMTs and tile''': |
− | ** You don't need to report about it.
| + | :- You don't need to report about it. |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| + | :- PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics. |
− | ** Problematic tiles and PMTs:
| + | :- Problematic tiles and PMTs: |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| + | ::• Sector 1 Tile 21 dead (PMT 55,56,57) |
− | *** Sector 1 Tile 1 PMT 2
| + | ::• Sector 1 Tile 1 PMT 2 |
− | *** Sector 4 Tile 34 PMT 92
| + | ::• Sector 4 Tile 34 PMT 92 |
| | | |
| == '''Beam Restoration''' == | | == '''Beam Restoration''' == |
| | | |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert. | + | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident doing this alone, contact the Beamline Expert. |
| | | |
− | * Find all Reference values on the white board at tab Short_Term_Schedule | + | * Find all Reference values on the CH whiteboard as well as the {{#switchtablink:Short_Term_Schedule|Short Term Schedule}} tab. |
| | | |
| === Restoring Beam after Short Downtime === | | === Restoring Beam after Short Downtime === |
| | | |
| * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after | | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after |
− | ** beam steering or orbit change
| + | :- beam steering or orbit change |
− | ** change in beam current, e.g., after a target change
| + | :- change in beam current, e.g., after a target change |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| + | :- If BPM 2C24A and 2H01 positions are off (not within +/-0.1 mm), ask MCC to bring them to the reference values |
| | | |
| === Beam Tuning to Tagger Yoke Dump === | | === Beam Tuning to Tagger Yoke Dump === |
| | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. | + | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. |
| * Contact Eugene Pasyuk if issues arise. | | * Contact Eugene Pasyuk if issues arise. |
| | | |
Line 1,099: |
Line 195: |
| * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF; | | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF; |
| * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values | | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values |
− | * Take harp scans | + | * Take harp scans: |
| :- at Harp 2C21A (Upstream Right Counter) | | :- at Harp 2C21A (Upstream Right Counter) |
| :- at Tagger Harp 2C24A Upstream Right Counter) | | :- at Tagger Harp 2C24A Upstream Right Counter) |
Line 1,110: |
Line 206: |
| === Møller run === | | === Møller run === |
| | | |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs]. | + | * Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs]. |
| * Contact Nathan Baltzell if issues arise | | * Contact Nathan Baltzell if issues arise |
| | | |
− | A few points to note: | + | * A few points to note: |
− | * '''Request 20 nA''' , Orbit Locks should be off
| + | :- '''Request 20 nA''' , Orbit Locks should be off |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| + | :- The BPMs 2C21 and 2C24A may be out of range after the Møller configuration. |
− | * Keep running until the polarization uncertainty is < 1.5%
| + | :- Keep running until the polarization uncertainty is < 1.5% |
| | | |
| === Beam Tuning to Faraday Cup === | | === Beam Tuning to Faraday Cup === |
| | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein. | + | * Study the manual [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam] and consider the first steps mentioned therein. |
| | | |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run). | + | * This is typically done after tuning to the tagger dump (and possibly taking a Moller run). |
| | | |
| * All CLAS12 detectors HV off (BMT HV in safe mode) | | * All CLAS12 detectors HV off (BMT HV in safe mode) |
Line 1,130: |
Line 226: |
| :- beam type electron | | :- beam type electron |
| :- beam blocker out | | :- beam blocker out |
− | * If initial beam tune, target should be "Empty" | + | * If initial beam tune, the target should be "Empty" |
| * Ask MCC to unmask beam halos | | * Ask MCC to unmask beam halos |
| * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds | | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds |
Line 1,141: |
Line 237: |
| * If good, log the new scan results. | | * If good, log the new scan results. |
| | | |
− | Once done and before resuming the production data-taking: | + | * Once done and before resuming the production data-taking: |
− | * Retract the Downstream Viewer from the beamline
| + | :- Retract the Downstream Viewer from the beamline |
− | * Put the FSDs thresholds and integration time to their reference values
| + | :- Put the FSDs thresholds and integration time to their reference values |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| + | :- Turn all detector HV ON, for MVT "HV ON - Full Voltage" |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| + | :- MCC might need to adjust the beam positions after going to the production beam current. |
− | | |
− | | |
− | | |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− | | |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− | | |
− | == '''Recent Changes''' ==
| |
− | | |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− | | |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− | | |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− | | |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− | | |
− | == '''Current Issues''' ==
| |
− | | |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− | | |
− | === Beamline ===
| |
− | | |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− | | |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | | |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− | | |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− | | |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− | | |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− | | |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− | | |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− | | |
− | == '''Beam Restoration''' ==
| |
− | | |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− | | |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− | | |
− | === Restoring Beam after Short Downtime ===
| |
− | | |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− | | |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− | | |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− | | |
− | * If good, log the new scan results.
| |
− | | |
− | === Møller run ===
| |
− | | |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− | | |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− | | |
− | === Beam Tuning to Faraday Cup ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− | | |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron | |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− | | |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− | | |
− | | |
− | | |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− | | |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− | | |
− | == '''Recent Changes''' ==
| |
− | | |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− | | |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− | | |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− | | |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− | | |
− | == '''Current Issues''' ==
| |
− | | |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− | | |
− | === Beamline ===
| |
− | | |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− | | |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | | |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− | | |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− | | |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− | | |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− | | |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− | | |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− | | |
− | == '''Beam Restoration''' ==
| |
− | | |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− | | |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− | | |
− | === Restoring Beam after Short Downtime ===
| |
− | | |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− | | |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− | | |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− | | |
− | * If good, log the new scan results.
| |
− | | |
− | === Møller run ===
| |
− | | |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− | | |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− | | |
− | === Beam Tuning to Faraday Cup ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− | | |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron
| |
− | :- beam blocker out | |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− | | |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− | | |
− | | |
− | | |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− | | |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− | | |
− | == '''Recent Changes''' ==
| |
− | | |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− | | |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− | | |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− | | |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− | | |
− | == '''Current Issues''' ==
| |
− | | |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− | | |
− | === Beamline ===
| |
− | | |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− | | |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | | |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− | | |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− | | |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− | | |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− | | |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− | | |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− | | |
− | == '''Beam Restoration''' ==
| |
− | | |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− | | |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− | | |
− | === Restoring Beam after Short Downtime ===
| |
− | | |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− | | |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− | | |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− | | |
− | * If good, log the new scan results.
| |
− | | |
− | === Møller run ===
| |
− | | |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− | | |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− | | |
− | === Beam Tuning to Faraday Cup ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− | | |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator | |
− | :- beam type electron
| |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− | | |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
− | | |
− | | |
− | | |
− | = Phone Numbers =
| |
− | <!--####################################### PHONE NUMBERS #############################################-->
| |
− | {{PhoneNumbers}}
| |
− | <!--- JUST MODIFY AND SAVE ANYTHING IN THIS COMMENT BLOCK TO FORCE A REFRESH OF THE PHONE NUMBERS TEMPLATE! -->
| |
− | | |
− | <!--####################################### Short Term Schedule #############################################-->
| |
− | = Short Term Schedule =
| |
− | | |
− | '''[https://wiki.jlab.org/clas12-run/index.php?title=Template:ShortTermSchedule-RGK&action=edit Click to Edit]''' solely this tab. P.S.: You must click on the top Edit, next to Read, followed by "Save changes" to force the current page to refresh. <br>
| |
− | | |
− | {{ShortTermSchedule-RGK}}
| |
− | | |
− | <!--####################################### GENERAL INFORMATION #############################################-->
| |
− | = General Information =
| |
− | | |
− | This tab contains information on
| |
− | * '''Recent Changes'''
| |
− | * '''Current Issues'''
| |
− | *'''Beam Restoration'''
| |
− | | |
− | == '''Recent Changes''' ==
| |
− | | |
− | === New '''MVT LV''' Reboot Procedure ===
| |
− | See '''https://logbooks.jlab.org/entry/4217011''' for detailed information on rebooting the MVT LV when observing a drop in BMT strip occupancies. This gets done upon request of DAQ or MVT expert only.
| |
− | * Turn '''LV OFF from MVT Overview->Low Voltage->MVT-All'''. LV status indicators should change from green to black;
| |
− | * '''Wait 20 seconds''', then '''turn LV back from the same menu'''.
| |
− | * In the alarm handler, with a 2-minute alarm delay, there can be an alarm "NActiveCrates", the status is also seen on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON.
| |
− | * Reboot mvt1, mvt2, and mvt3 ROCS.
| |
− | * Start a run with restart DAQ (Cancel → Reset → Configure → Download → Prestart → Go).
| |
− | * '''If we have beam, and a reboot process takes more than 5 min, call the DAQ or MVT expert'''.
| |
− | | |
− | === RICH issues ===
| |
− | * The RICH fibers alarm leads to web guidance aka logbook entry [https://logbooks.jlab.org/entry/3562273 3562273 - RICH recovery procedure].
| |
− | * Check the RICH manual for the current guidance: '''https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf'''
| |
− | * See below for current issues
| |
− | | |
− | === Rapid/Controlled Access to the Hall ===
| |
− | * Ask MCC to stop the beam. Wait for the beacon to stop flashing (15-20 minutes) before access. Rapid access is controlled access without RadCon.
| |
− | * After higher beam current or a Moller run, the beacon will not stop flashing anytime soon. Then, escorted access, viz the ARM, is needed. In that case, keep the beam until the ARM arrives at the Counting House.
| |
− | | |
− | === 24/7 ZOOM connection for Counting House ===
| |
− | * Click on [https://jlab-org.zoomgov.com/j/1618614939 https://jlab-org.zoomgov.com/j/1618614939], included in "Remote Shifts" in tab "Shift Worker"
| |
− | * choose the option to "'''join from browser'''" (''Chrome is recommended'') and ignore all other messages to update the ZOOM APP in the pop-up windows,.
| |
− | * Enter the passcode from the logbook entry in tab "Shift Worker"
| |
− | | |
− | == '''Current Issues''' ==
| |
− | | |
− | === Lights in the Hall ===
| |
− | The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights must be OFF because of light leaks of some of the detectors. If these lights are switched on during an access, they '''should be switched off when leaving the Hall'''.
| |
− | * Refer to these photos: ON: [https://logbooks.jlab.org/entry/3825712], OFF: [https://logbooks.jlab.org/entry/3825731]
| |
− | * We have a '''new dome light switch outside of the hall''' in the labyrinth. See logbook entry: https://logbooks.jlab.org/entry/4204460
| |
− | * When the dome lights are switched off, they cannot be turned back on immediately, they require 10-15 min to cool down.
| |
− | | |
− | === Beamline ===
| |
− | | |
− | * Orbit locks are on BPMs '''2C24A and 2H01''' and the locks should generally be on ("Running").
| |
− | ** Beam positions at 2C24A and 2H01 have to be kept, within ±0.1mm, at the nominal beam positions listed below ("Reference Values").
| |
− | * The beam position at '''2C21A''' is not important for production runs but should be stable. Here, significantly drifting positions can indicate instabilities in beam energy.
| |
− | ** The beam position at 2C21A is important for initial beam tuning (on tagger dump).
| |
− | *'''After the HWP change'''
| |
− | ** The absolute values of the SLM and FCUP '''charge asymmetry''' (Q-Asym) should be less than 0.1%. If they are not, contact the Beamline Expert.
| |
− | ** Start a new run
| |
− | * '''Tagger Magnet Procedure:''' If the tagger magnet needs to be turned off, tell the operator to '''ONLY''' use '''the script for degaussing, NEVER do it "by hand"!''' The latter method might/will trip the circuit breaker for the power supply in the Hall.
| |
− | | |
− | === BMT / SVT ===
| |
− | * If new hot channels appear, '''call the SVT/MM expert Yuri Gotra''' (757-541-7539). These channels need to be addressed by the expert.
| |
− | * '''BMT HV trips''': no screenshots are necessary, power-cycle the channel HV '''as fast as possible''' (the ''underlying script will take care of ramping it up''), note the information in the shift summary. If the same channel trips frequently, ask the expert on call for guidance.
| |
− | * BMT HV S1 L2 STRIP in safe mode (low voltage) by expert - appears blue in MVT overview
| |
− | * BMT HV S1 L5 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | * BMT HV S2 L6 STRIP and DRIFT are OFF (Vset=0V) - appears blue in MVT overview
| |
− | | |
− | === CND ===
| |
− | * CAMAC crate alarm:
| |
− | ** CAMAC crate (CND Constant Fraction Discriminators) needs rebooting, can be done via the alarm handler.
| |
− | ** After reboot, the CFD thresholds need to be set by running a script, see page 12 in the CND manual at tab "General", https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf
| |
− | | |
− | === DAQ ===
| |
− | * Some ROCs keep printing error messages while functioning properly; please see their list in this logbook entry # [https://logbooks.jlab.org/entry/4215299 4215299] to avoid unnecessary reboots since the printout in the ROC terminal won't change. The message will appear in the DAQ run control if they get disconnected!
| |
− | * <font color=red>'''NEW STANDARD''' end and start of the run:</font> End run, Cancel, Reset, <u> Download</u> , Prestart, Go. This will ensure proper compression of the FADCs and therefore a smaller data rate.
| |
− | * roc reboot instructions:
| |
− | ** To reboot i.e. adcecal1, type on a clasrun terminal: clasrun> roc_reboot adcecal1
| |
− | ** To check that the crate is back alive, type:clasrun> ping adcecal1
| |
− | ** The ping will start to answer as soon as the crate communicates again.
| |
− | | |
− | === DC ===
| |
− | * Make sure to log every DC trip in the shift summary. Make sure to list WHERE and why, possibly, the trip occurred.
| |
− | | |
− | === ECAL/PCAL ===
| |
− | * "ECAL_SEC6_UO26 Noisy" https://logbooks.jlab.org/entry/4241957
| |
− | * "PCAL_HV_SEC2_U25 turned off" https://logbooks.jlab.org/entry/4247187, https://logbooks.jlab.org/entry/4247400
| |
− | | |
− | === FTOF ===
| |
− | * FTOF S2 Paddle 19-left and S4 Paddle 16-left are known to be "weak" channels that tend to come and go depending on torus polarity and rates. This cannot be fixed during this run period; see https://logbooks.jlab.org/entry/4219555 and https://logbooks.jlab.org/entry/4219876.
| |
− | * "FTOF HV Adjustment - S5 P2 2R" https://logbooks.jlab.org/entry/4249754
| |
− | | |
− | === RICH ===
| |
− | * '''Known problematic PMTs and tile''':
| |
− | ** You don't need to report about it.
| |
− | ** PMT 2 (sector 1) and PMT 92 (sector 4) are not completely dead and may be visible depending on statistics.
| |
− | ** Problematic tiles and PMTs:
| |
− | *** Sector 1 Tile 21 dead (PMT 55,56,57)
| |
− | *** Sector 1 Tile 1 PMT 2
| |
− | *** Sector 4 Tile 34 PMT 92
| |
− | | |
− | == '''Beam Restoration''' ==
| |
− | | |
− | * Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam]. If you do not feel confident to do this by yourself, contact the Beamline Expert.
| |
− | | |
− | * Find all Reference values on the white board at tab Short_Term_Schedule
| |
− | | |
− | === Restoring Beam after Short Downtime ===
| |
− | | |
− | * Ask for 5 nA beam current and check the 2C24A and 2H01 beam (x, y) positions against the Reference Values (tab "Short Term Schedule") after
| |
− | ** beam steering or orbit change
| |
− | ** change in beam current, e.g., after a target change
| |
− | ** If BPM 2C24A and 2H01 positions are off, (not within +/-0.1 mm), ask MCC to bring them to the reference values
| |
− | | |
− | === Beam Tuning to Tagger Yoke Dump ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam].
| |
− | * Contact Eugene Pasyuk if issues arise.
| |
− | | |
− | * Ask MCC to energize the tagger magnet
| |
− | :- blank collimator
| |
− | :- beam type "Photon"
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to mask the beam halo counters (FSDs: Upstream, Midstream, Downstream, BOM)
| |
− | * Ask MCC for 5 nA beam current and make sure the Orbit Locks are OFF;
| |
− | * If necessary, ask MCC to bring the 2C21A and 2C24A beam positions to the Reference Values
| |
− | * Take harp scans
| |
− | :- at Harp 2C21A (Upstream Right Counter)
| |
− | :- at Tagger Harp 2C24A Upstream Right Counter)
| |
− | * If the beam trips, abort the scan and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * The fit ranges might need to be adjusted manually to assess the fit results
| |
− | | |
− | * If good, log the new scan results.
| |
− | | |
− | === Møller run ===
| |
− | | |
− | Follow the standard procedure as described in the manual [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf Performing Møller Runs].
| |
− | * Contact Nathan Baltzell if issues arise
| |
− | | |
− | A few points to note:
| |
− | * '''Request 20 nA''' , Orbit Locks should be off
| |
− | * The BPMs 2C21 and 2C24A may be out of range after the Møller configuration.
| |
− | * Keep running until the polarization uncertainty is < 1.5%
| |
− | | |
− | === Beam Tuning to Faraday Cup ===
| |
− | | |
− | Study the manual: [https://raw.githubusercontent.com/JeffersonLab/clas12-manuals/master/beamline/manual/beam_estab_rgd.pdf Establishing Physics-Quality Beam], and take into account the first steps mentioned therein.
| |
− | | |
− | This is typically done after tuning to the tagger dump (and possibly taking a Moller run).
| |
− | | |
− | * All CLAS12 detectors HV off (BMT HV in safe mode)
| |
− | | |
− | * Ask MCC to de-energize the tagger magnet
| |
− | :- 20 mm collimator
| |
− | :- beam type electron
| |
− | :- beam blocker out
| |
− | * If initial beam tune, target should be "Empty"
| |
− | * Ask MCC to unmask beam halos
| |
− | * Set the halo counter FSD thresholds to 1 MHz and the integration time interval to 50 milliseconds
| |
− | * Insert the Downstream Viewer, Chromax, in the beamline
| |
− | * Ask MCC for 5 nA beam current
| |
− | * If necessary, ask MCC to bring the beam positions at 2C24A and 2H01 to the Reference Values
| |
− | * Take a harp scan at 2H01 (Midstream Left)
| |
− | * If the beam trips, abort and restart. The beam must be on during the scan, otherwise the fit to the beam profile will not work.
| |
− | * Compare the results with the Harp Scan References
| |
− | * If good, log the new scan results.
| |
− | | |
− | Once done and before resuming the production data-taking:
| |
− | * Retract the Downstream Viewer from the beamline
| |
− | * Put the FSDs thresholds and integration time to their reference values
| |
− | * Turn all detector HV ON, for MVT "HV ON - Full Voltage"
| |
− | * MCC might need to adjust the beam positions after going to the production beam current.
| |
| | | |
| <!--####################################### Shift Expert ################################################--> | | <!--####################################### Shift Expert ################################################--> |
| = Shift Expert = | | = Shift Expert = |
| | | |
− | Come to your shift in time for the '''shift change''', 10-15 minutes before the start of your shift.
| + | * Arrive at your shift in time for the '''shift change''', 10-15 minutes before the start of your shift. |
− | * If it is your first shift or a shift after a long pause, do <font color=red> '''shadow an earlier shift for at least 4 hours''' </font> to familiarize yourself with all shift duties and technicalities of the ongoing experiment.
| + | :- If it is your first shift or a shift after a long pause, do <font color=red> '''shadow an earlier shift for at least 4 hours''' </font> to familiarize yourself with all shift duties and technicalities of the ongoing experiment. |
| | | |
− | Follow the '''Short Term Schedule''' | + | * Follow the '''{{#switchtablink:Short_Term_Schedule|Short Term Schedule}}'''; |
− | * The RC must be notified before changing run conditions
| + | :- The RC must be notified before changing run conditions. |
| | | |
− | Operate the '''Data Acquisition''' | + | * Operate the '''Data Acquisition'''. |
| | | |
− | Take action on and log '''alarms''' | + | * Take action on and log '''alarms'''. |
| | | |
− | At '''the end of the shift''', submit the '''strip charts''' to the logbook
| + | * '''Communicate''' with your co-shift person: |
− | * If they are not up already: (CS-Studio → Tools → Strip Charts → livePlot)
| + | :- Remind them to read the tab 'Shift Worker'. |
− | * Right click within the grid, choose "Load a Configuration", select "Beamline4Logbook_visibleHaloCounters"
| + | :- The shift worker should discuss an issue with the shift expert before making extra logbook entries. |
− | * Choose a '''time-span width of 10 hours''' (right-click below x-axis)
| + | :- During production, not in extended downtime, the shift expert should ensure the shift worker is filling their '''end-of-shift Checklist''' when the beam is ON, not in the period of beam trips. |
− | * <font color=red> To make a logbook entry:</font>
| + | :- <font color=red> Use the CS-Studio '''Logbook entry tool''' for all screenshots (but the strip charts)!</font> |
− | :- Right click within the grid of one of the charts, choose "Make Logbook Entry" | + | :- Note that the Logbook Entry tool defaults the entry in the HBRUN logbook. Other logbooks can be added or selected from the drop-down menu. |
− | :- The title of the logbook entry can be changed, eg to Strip charts
| |
− | :- Un-click ELOG, select HBLOG, and click on "Make Entry" to submit
| |
| | | |
− | '''Communicate''' with your co-shift person:
| + | * Check for and read any comments made to '''log-book entries''' during your shift. |
− | * Remind them to read the tab 'Shift Worker'. | |
− | * Discuss any issues with the shift worker before making extra logbook entries.
| |
− | * Remind the shift worker of the '''end-of-shift Checklist'''.
| |
− | * <font color=red> Use the CS-Studio '''Logbook entry tool''' for all screen shots (but the strip charts)!</font>
| |
− | * Note that the Logbook Entry tool puts the entry in the HBRUN logbook by default. Other logbooks can be added or selected from the drop down menu.
| |
| | | |
− | Check for and read any comments to '''logbook entries''' made during your shift.
| + | * Keep your '''shift summary''' up to date in HBLOG. Record all shift activities, issues, if any, and related communications with experts with details and/or reference to any associated logbook entries: |
| + | :- Refer to relevant logbook entries in the shift summary. |
| + | :- Include a list of runs taken during the shift with relevant run information; |
| + | ::- See, for instance, this [https://logbooks.jlab.org/entry/4214804 shift summary] where all relevant run info, links, and shift activities are cited. |
| | | |
− | Keep your '''shift summary''' up to date in HBLOG. Record all significant happenings.
| + | * Ensure that all '''MON12 monitoring plots''' are logged and checked against the reference plots for every single run; see the links under {{#switchtablink:Monitoring|Monitoring}} tab; |
− | * Refer to relevant logbook entries in the shift summary. | + | :- Both, you and the shift worker should run MON12 and '''reset & check spectra frequently'''. |
− | * Include a run list for the shift with relevant run information.
| |
− | | |
− | Ensure that all '''monitoring plots''' and are logged and checked against the reference plots for every single run. | |
− | * Both, you and the shift worker should run mon12 and '''reset & check spectra frequently'''.
| |
| | | |
| * If the worker shift is remote, maintain communication over Zoom. | | * If the worker shift is remote, maintain communication over Zoom. |
Line 1,877: |
Line 277: |
| * If you have any other questions or uncertainties about what to do, call the RC. | | * If you have any other questions or uncertainties about what to do, call the RC. |
| | | |
− | The shift worker (if in person) should log the '''clas12online'' reconstruction plots at the end of a run. Running the program on more than one CH computer has been causing problems.
| + | * In case of '''RICH issues''', check the RICH manual for the current guidance: https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf |
| | | |
− | In case of '''RICH issues''', check the RICH manual for the current guidance: https://github.com/JeffersonLab/clas12-manuals/blob/master/rich/Novice/RICH_Controls.pdf
| + | * '''New MVT LV Reboot Procedure''' can be found in the {{#switchtablink:General_Information|General_Information}} tab. |
| | | |
− | '''New MVT LV Reboot Procedure''' can be found at tab 'GENERAL INFORMATION'. | + | * At '''the end of the shift''', submit the '''strip charts''' to the logbook: |
| + | :- If they are not up already: (CS-Studio → Tools → Strip Charts → livePlot) |
| + | :- Right-click within the grid, choose "Load a Configuration", select "Beamline4Logbook_visibleHaloCounters" |
| + | :- Choose a '''time-span width of 10 hours''' (right-click below x-axis) |
| + | :- <font color=red> To make a logbook entry:</font> |
| + | ::• Right-click within the grid of one of the charts, choose "Make Logbook Entry" |
| + | ::• The title of the logbook entry can be changed, eg to Strip charts |
| + | ::• Un-click ELOG, select HBLOG and click "Make Entry" to submit. |
| | | |
− | '''[https://ace.jlab.org/btm Fill out BTA]''' hourly; | + | * '''[https://ace.jlab.org/btm Fill out BTA]''' hourly; |
| * Accelerator beam time (do not change these values): | | * Accelerator beam time (do not change these values): |
− | ** ABU: acceptable beam used
| + | :- ABU: acceptable beam used |
− | ** BANU: beam acceptable but not used (should be reflected in our PCC and UED)
| + | :- BANU: beam acceptable but not used (should be reflected in our PCC and UED) |
− | ** BNA: beam not acceptable (e.g., tuning, drifting, not focused)
| + | :- BNA: beam not acceptable (e.g., tuning, drifting, not focused) |
− | ** ACC: Accelerator Configuration Change (e.g., pass change)
| + | :- ACC: Accelerator Configuration Change (e.g., pass change) |
− | ** OFF: Accelerator is down
| + | :- OFF: Accelerator is down |
| * Experiment beam time (do change these values): | | * Experiment beam time (do change these values): |
− | ** ER: Experiment ready (should be 60 minutes - PCC - UED)
| + | :- ER: Experiment ready (should be 60 minutes - PCC - UED) |
− | ** PCC: Planned configuration change (when the beam is masked while radiators are moved, target change, DAQ (stopping/starting runs, tests, etc.)
| + | :- PCC: Planned configuration change (when the beam is masked while radiators are moved, target change, DAQ (stopping/starting runs, tests, etc.) |
− | ** UED: Unplanned experiment down (hardware failure, DAQ crashes, our problems, ...)
| + | :- UED: Unplanned experiment down (hardware failure, DAQ crashes, our problems, ...) |
− | ** ''Exception'': ''BANU, due to time spent on beam tuning and BPM checks after beam down, should be counted as ER on our side''.
| + | :- ''Exception'': ''BANU, due to time spent on beam tuning and BPM checks after beam down, should be counted as ER on our side''. |
| * Enter fields at the "Shift Information" tab. | | * Enter fields at the "Shift Information" tab. |
− | * You must save at 7:00, 15:00, and 23:00, to send info to MCC. To see the save button, click 'edit all' or 'edit cc hours.' | + | * To send information to MCC, you must save at 7:00, 15:00, and 23:00. To see the save button, click 'edit all' or 'Edit CC Hours.' |
| * Acknowledge the popup error message about the last hour not being completed by clicking OK. | | * Acknowledge the popup error message about the last hour not being completed by clicking OK. |
| * Sign, viz log completed 8-hour sheet. | | * Sign, viz log completed 8-hour sheet. |
| * '''Note: we can change the time sheet up to 48 hours after completion.''' | | * '''Note: we can change the time sheet up to 48 hours after completion.''' |
| + | |
| | | |
| <!--####################################### Shift Worker ################################################--> | | <!--####################################### Shift Worker ################################################--> |
Line 1,979: |
Line 387: |
| * '''Report at the PD/RC and attend the MCC/OPS meetings''' (weekdays 7:45 AM and 8 AM Daily, MCC building). The PD will communicate when and how meetings happen on the weekend. | | * '''Report at the PD/RC and attend the MCC/OPS meetings''' (weekdays 7:45 AM and 8 AM Daily, MCC building). The PD will communicate when and how meetings happen on the weekend. |
| | | |
− | * Update the run plan in tab '''{{#switchtablink:Short_Term_Schedule|Short Term Schedule}}''' (and on the white board in CH) in coordination with the RG-K experiment coordinators (i.e., Annalisa, Daniel) and communicate it to the shift crew. | + | * Update the run plan in the '''{{#switchtablink:Short_Term_Schedule|Short Term Schedule}}''' tab (and on the whiteboard in CH) in coordination with the RG-K experiment coordinators (i.e., Annalisa, Daniel) and communicate it to the shift crew. |
| | | |
| * Log the '''RC Daily summary''' in the HBLOG. | | * Log the '''RC Daily summary''' in the HBLOG. |
Line 1,985: |
Line 393: |
| * Update the '''list of runs''' taken on the [https://docs.google.com/spreadsheets/d/1xplXDIiio_TkimucPBSf7i-bAbbM7mpWzZ1zevt4edQ/edit#gid=0 Google Spreadsheet] | | * Update the '''list of runs''' taken on the [https://docs.google.com/spreadsheets/d/1xplXDIiio_TkimucPBSf7i-bAbbM7mpWzZ1zevt4edQ/edit#gid=0 Google Spreadsheet] |
| | | |
− | * '''[[https://ace.jlab.org/btm/timesheet/eb BTA time sheet]''': Make sure, the "Beam Available Not Used" (BANU) time is accounted for as explained at tab {{#switchtablink:Shift_Expert|Shift Expert}}. The BTA information can be modified post-signature. | + | * '''[https://ace.jlab.org/btm/timesheet/eb BTA time sheet]''': Make sure the "Beam Available Not Used" (BANU) time is accounted for as explained at the {{#switchtablink:Shift_Expert|Shift Expert}} tab. The BTA information can be modified post-signature. |
− | ** NOTE: "After 48 hours you cannot modify a User signed timesheet unless you are the signer, Hall Manager, or Admin" | + | ** NOTE: "After 48 hours, you cannot modify a User signed timesheet unless you are the signer, Hall Manager, or Admin". |
| | | |
| * Run the daily '''RC meetings''' in CH Room 200C and on ZOOM | | * Run the daily '''RC meetings''' in CH Room 200C and on ZOOM |
Line 1,992: |
Line 400: |
| ** Wednesdays at 3 PM, zoom only | | ** Wednesdays at 3 PM, zoom only |
| ** Weekends upon agreement | | ** Weekends upon agreement |
− | ** Send a '''daily invitation''' for the RC meeting to mailing lists hallb, clas12_rgk, clas_members. | + | ** Send a '''daily invitation''' for the RC meeting to mailing lists hallb, clas12_rge, clas_members. |
− | ** Keep the '''Daily RC Meeting Minutes''' at [https://clasweb.jlab.org/wiki/index.php/Run_Group_K Run_Group_K wiki], tab "RGK FALL 2023 / SPRING 2024"
| |
| | | |
| * Connect to '''Zoom in CH Room 200C''': | | * Connect to '''Zoom in CH Room 200C''': |
| ** Turn on the projector with the white remote control, then log into your CUE account. If not listed yet, click "Not listed?" in the bottom left to add your account. | | ** Turn on the projector with the white remote control, then log into your CUE account. If not listed yet, click "Not listed?" in the bottom left to add your account. |
| ** Once logged in, use the recommended Google Chrome to join the ZOOM meeting on the browser or use the ZOOM application. | | ** Once logged in, use the recommended Google Chrome to join the ZOOM meeting on the browser or use the ZOOM application. |
− | ** Since the room doesn't have audio, don't connect with the computer audio, but choose "Call Me," then enter the number in the small Cisco answering device. Once it rings, answer the call, and you will be prompted to join the meeting. | + | ** Since the room doesn't have audio, don't connect with the computer audio, but '''Call the 1-833-xxx-xxxx number shown in the ZOOM session on the small Cisco answering device'''. Once prompted, enter the '''meeting ID''' followed by the '''participant ID''' displayed in the ZOOM session to join the meeting. |
| ** The room has a camera, which can be turned on via ZOOM. | | ** The room has a camera, which can be turned on via ZOOM. |
| | | |
Line 2,005: |
Line 412: |
| *'''MCC/OPS planning meeting''', on Wednesdays at 13:30, MCC building. | | *'''MCC/OPS planning meeting''', on Wednesdays at 13:30, MCC building. |
| ** Submit (save) the online form '''[https://ace.jlab.org/apps/pd/run-coordinator-reports Run Coordinator Weekly Summary]''' before the meeting and present the contents at the meeting. | | ** Submit (save) the online form '''[https://ace.jlab.org/apps/pd/run-coordinator-reports Run Coordinator Weekly Summary]''' before the meeting and present the contents at the meeting. |
− | ** The summary covers the data taking status '''from 7 am on the previous Wednesday to 7 am on the current Wednesday'''. | + | ** The summary covers the data-taking status '''from 7 a.m. on the previous Wednesday to 7 a.m. on the current Wednesday'''. |
| ** '''Beam time accounting''': [https://ace.jlab.org/btm/reports/physics-summary Beam Time Manager; Physics Time Accounting] | | ** '''Beam time accounting''': [https://ace.jlab.org/btm/reports/physics-summary Beam Time Manager; Physics Time Accounting] |
− | ** For the '''percentage of scheduled experiment hours to date''' contact Daniel Carman.
| + | ** The '''total experiment data collected to date''' could be retrieved from the up-to-date "Accumulated Charge" depicted on the "RGE 2024 Progress" plot. See the {{#switchtablink:Monitoring|Monitoring}} tab |
− | ** The '''total experiment data collected to date''' can be retrieved from the up-to-date "Accumulated Charge" depicted at [https://clasweb.jlab.org/clas12online/timelines/rg-k/RGK2024_progress_all.html] | + | *'''Hall B meeting''' is on Mondays at 9 AM. Present your summary slides, which should be sent beforehand to the Hall B leader, Patrick Achenbach. |
− | | |
− | *'''Hall B meeting''' is on Mondays at 9 AM. Present your summary slides that should be sent beforehand to the Hall B leader, Patrick Achenbach. | |
| | | |
| | | |
Line 2,034: |
Line 439: |
| | valign=top | | | | valign=top | |
| === Data Quality === | | === Data Quality === |
− | * mon12 histograms: [https://clas12mon.jlab.org/mon12/histograms/?reference=4263114 reference (run 19868)] | + | * MON12 histograms: reference and most recent uploads |
| + | :• '''New''': LD2+Al dual-target @ 70 nA: [https://clas12mon.jlab.org/mon12/histograms/?reference=4299824 run #: 20438] |
| + | :• '''Old''': LD2+Sn dual-target @ 65 nA: [https://clas12mon.jlab.org/mon12/histograms/?reference=4295017 run #: 20367] |
| * [https://clasweb.jlab.org/hydra/dashboard2.html Hydra] (CUE Login) Google-Chrome ONLY, Not Firefox! | | * [https://clasweb.jlab.org/hydra/dashboard2.html Hydra] (CUE Login) Google-Chrome ONLY, Not Firefox! |
− | * [https://github.com/JeffersonLab/caos/tree/main#readme clas12mltrack/clas12online]: | + | * [https://github.com/JeffersonLab/caos/tree/main#readme clas12mltrack]: real-time reconstructed vertices & various event topologies |
− | :• '''New'''; displaying real-time reconstructed vertices & various event topologies
| + | * [https://clasweb.jlab.org/clas12online/timelines/rg-e/RGE2024_progress_all_charge.html] Data CHARGE accumulation timeline [https://clasweb.jlab.org/clas12online/timelines/rg-e/RGE2024_progress_all_lumi_unzoom.html] LUMINOSITY accumulation timeline |
− | * [https://clasweb.jlab.org/clas12online/timelines/rg-k/RGK2024_progress_all.html Data Accumulation Timeline] [https://clasweb.jlab.org/clas12online/timelines/rg-k/RGK2024_progress_all.pdf PDF] [https://clasweb.jlab.org/clas12online/timelines/rg-k/RGK2024_progress_all.xlsx Excel Spreadsheet] | + | <!--https://clasweb.jlab.org/clas12online/timelines/rg-e/RGE2024_progress_all_lumi.html] --> |
| |} | | |} |
| | | |
Line 2,048: |
Line 455: |
| ===Hall-B=== | | ===Hall-B=== |
| * [https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc Operation Safety Procedures] | | * [https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc Operation Safety Procedures] |
− | * [https://clasweb.jlab.org/wiki/index.php/Run_Group_K Run Group K Analysis Wiki] | + | * [https://clasweb.jlab.org/wiki/index.php/Run_Group_E Run Group E Analysis Wiki] |
| * [http://clasweb.jlab.org/rcdb RCDB] | | * [http://clasweb.jlab.org/rcdb RCDB] |
| * [https://clasweb.jlab.org/cgi-bin/ccdb/objects CCDB] | | * [https://clasweb.jlab.org/cgi-bin/ccdb/objects CCDB] |
Line 2,056: |
Line 463: |
| * [http://accboard.acc.jlab.org Accelerator Whiteboard] | | * [http://accboard.acc.jlab.org Accelerator Whiteboard] |
| * [https://accweb.acc.jlab.org/apps/pd/shift-plans Program Deputy Shift Plans] | | * [https://accweb.acc.jlab.org/apps/pd/shift-plans Program Deputy Shift Plans] |
− | * [https://cebaf.jlab.org/pd/run-coordinator-reports Run Coordinator Reports] | + | * [https://ace.jlab.org/apps/pd/run-coordinator-reports Run Coordinator Reports] |
| * [https://ace.jlab.org/btm/reports/physics-summary Beam Time Accounting Reports] | | * [https://ace.jlab.org/btm/reports/physics-summary Beam Time Accounting Reports] |
| * [https://opsweb.acc.jlab.org/CSUEApps/PSSestamp/psslog.php?numdays=5&entry_types_wanted%5BACCESS%5D=ACCESS&group_by=AREA&output_format=SCROLLABLE PSS Elog] | | * [https://opsweb.acc.jlab.org/CSUEApps/PSSestamp/psslog.php?numdays=5&entry_types_wanted%5BACCESS%5D=ACCESS&group_by=AREA&output_format=SCROLLABLE PSS Elog] |
Line 2,063: |
Line 470: |
| | valign=top | | | | valign=top | |
| ===ZOOM Meetings=== | | ===ZOOM Meetings=== |
− | * 07:45 [https://jlab-org.zoomgov.com/j/1611456010?pwd=d2RJWTJQRDM0ZkNaZ1dpTmtLWDAwQT09 RC/PD Morning Meeting] | + | * 07:45 [https://jlab-org.zoomgov.com/j/1611740648 RC/PD Morning Meeting], passcode is 933173 |
| * 08:00 [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 MCC/OPS Morning and Wednesday 1:30 Meeting] | | * 08:00 [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 MCC/OPS Morning and Wednesday 1:30 Meeting] |
| * [https://logbooks.jlab.org/entry/4000274 See also this logbook entry] | | * [https://logbooks.jlab.org/entry/4000274 See also this logbook entry] |
| * Daily Hall B Run Coordinator Meeting: | | * Daily Hall B Run Coordinator Meeting: |
− | ** [https://jlab-org.zoomgov.com/j/1613823885?pwd=U0FYcUNObys4dEZmRlNnbG1aVDN4UT09 URL Link] (''including Passcode'') | + | ** [https://jlab-org.zoomgov.com/j/1605705819#success URL Link] (''including Passcode'') |
− | ** Meeting ID: 161 382 3885 | + | ** Meeting ID: 160 570 5819 |
| ** Passcode: see emails | | ** Passcode: see emails |
| * [https://logbooks.jlab.org/entry/4158818 Hall B Remote Shifts & Counting House] | | * [https://logbooks.jlab.org/entry/4158818 Hall B Remote Shifts & Counting House] |
Line 2,086: |
Line 493: |
| | | |
| | | |
− | = Run Coordinator = | + | <!--= Run Coordinator =--> |
| <!--####################################### Run Coordinator ################################################--> | | <!--####################################### Run Coordinator ################################################--> |
− | {{RunCoordinatorDuties}} | + | <!--{{RunCoordinatorDuties}}--> |
| | | |
− | = Shift Expert = | + | <!--= Shift Expert =--> |
| <!--####################################### Shift Expert ################################################--> | | <!--####################################### Shift Expert ################################################--> |
| | | |
− | == Tasks == | + | <!--== Tasks == |
| | | |
| * Come to your shift in time for the '''shift change''', 10-15 minutes before the start of your shift. | | * Come to your shift in time for the '''shift change''', 10-15 minutes before the start of your shift. |
Line 2,128: |
Line 535: |
| *# In the alarm handler, with a 2-minute alarm delay, there can be alarm NActiveCrates, status also reported on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON; | | *# In the alarm handler, with a 2-minute alarm delay, there can be alarm NActiveCrates, status also reported on the MVT Overview GUI. This alarm will be cleared 2 min after LV is turned back ON; |
| *# At this point, mvt1, mvt2, and mvt3 ROCS can be rebooted; | | *# At this point, mvt1, mvt2, and mvt3 ROCS can be rebooted; |
− | *# Start a run by initializing DAQ from scratch: cancel-->reset-->configure-->download-->Prestart-->Go. | + | *# Start a run by initializing DAQ from scratch: cancel->reset->configure->download->Prestart->Go. |
| *# '''If the beam is ON, and a reboot process takes more than 5 min, please call the DAQ and/or SVT/MVT/MM expert'''. | | *# '''If the beam is ON, and a reboot process takes more than 5 min, please call the DAQ and/or SVT/MVT/MM expert'''. |
| | | |
− | * '''[https://bta.acc.jlab.org Fill out BTA]''' hourly; | + | * '''[https://bta.acc.jlab.org Fill out BTA]''' hourly;--> |
| | | |
− | = Shift Worker = | + | <!--= Shift Worker =--> |
| <!--####################################### Shift Worker ################################################--> | | <!--####################################### Shift Worker ################################################--> |
− | == Tasks == | + | <!--== Tasks == |
| | | |
| * Come to your shift in time for the shift change, 10-15 minutes before the start of your shift; | | * Come to your shift in time for the shift change, 10-15 minutes before the start of your shift; |
Line 2,175: |
Line 582: |
| :- EPICS GUIs should be accessed '''ONLY''' via the desktop menu or by running <tt>clascss-remote</tt>. | | :- EPICS GUIs should be accessed '''ONLY''' via the desktop menu or by running <tt>clascss-remote</tt>. |
| <!--* [https://userweb.jlab.org/~baltzell/clas12/shift/remote-demo.mp4 Remote Demonstration Video (150 MB)]--> | | <!--* [https://userweb.jlab.org/~baltzell/clas12/shift/remote-demo.mp4 Remote Demonstration Video (150 MB)]--> |
− | :◊ Some charts are also accessible via web browser: [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Upstream+and+Midstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scaler_cS3b&pv=scaler_cS4b&pv=scaler_cS6b&pv=scaler_cS12b&pv=scaler_cS13b&pv=scaler_cS14b&pv=scaler_cS15b&scaler_cS3blabel=scaler_cS3b&scaler_cS3bcolor=%23a6cee3&scaler_cS3byAxisLabel=Rate++%28Hz%29&scaler_cS3byAxisMin=&scaler_cS3byAxisMax=&scaler_cS3byAxisLog&scaler_cS3bscaler=&start=2020-08-08+09%3A02%3A36&end=2020-08-08+09%3A07%3A36&scaler_cS4blabel=scaler_cS4b&scaler_cS4bcolor=%231f78b4&scaler_cS4byAxisLabel=&scaler_cS4byAxisMin=&scaler_cS4byAxisMax=&scaler_cS4byAxisLog=&scaler_cS4bscaler=&scaler_cS5byAxisLabel=&scaler_cS5byAxisMin=&scaler_cS5byAxisMax=&scaler_cS5byAxisLog=&scaler_cS5bscaler=&scaler_cS6blabel=scaler_cS6b&scaler_cS6bcolor=%2333a02c&scaler_cS6byAxisLabel=&scaler_cS6byAxisMin=&scaler_cS6byAxisMax=&scaler_cS6byAxisLog=&scaler_cS6bscaler=&scaler_cS7byAxisLabel=&scaler_cS7byAxisMin=&scaler_cS7byAxisMax=&scaler_cS7byAxisLog=&scaler_cS7bscaler=&scaler_cS12blabel=scaler_cS12b&scaler_cS12bcolor=%23e31a1c&scaler_cS12byAxisLabel=&scaler_cS12byAxisMin=&scaler_cS12byAxisMax=&scaler_cS12byAxisLog=&scaler_cS12bscaler=&scaler_cS13blabel=scaler_cS13b&scaler_cS13bcolor=%23fdbf6f&scaler_cS13byAxisLabel=&scaler_cS13byAxisMin=&scaler_cS13byAxisMax=&scaler_cS13byAxisLog=&scaler_cS13bscaler=&scaler_cS14blabel=scaler_cS14b&scaler_cS14bcolor=%23ff7f00&scaler_cS14byAxisLabel=&scaler_cS14byAxisMin=&scaler_cS14byAxisMax=&scaler_cS14byAxisLog=&scaler_cS14bscaler=&scaler_cS15blabel=scaler_cS15b&scaler_cS15bcolor=%23cab2d6&scaler_cS15byAxisLabel=&scaler_cS15byAxisMin=&scaler_cS15byAxisMax=&scaler_cS15byAxisLog=&scaler_cS15bscaler= Upstream/Midstream Halo Counters], [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Downstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scalerS8b&pv=scalerS9b&scalerS8blabel=scalerS8b&scalerS8bcolor=%23a6cee3&scalerS8byAxisLabel=Rate++%28Hz%29&scalerS8byAxisMin=&scalerS8byAxisMax=&scalerS8byAxisLog&scalerS8bscaler=&pv=scalerS10b&pv=scalerS11b&scalerS9blabel=scalerS9b&scalerS9bcolor=%231f78b4&scalerS9byAxisLabel=&scalerS9byAxisMin=&scalerS9byAxisMax=&scalerS9byAxisLog=&scalerS9bscaler=&scalerS10blabel=scalerS10b&scalerS10bcolor=%23b2df8a&scalerS10byAxisLabel=&scalerS10byAxisMin=&scalerS10byAxisMax=&scalerS10byAxisLog=&scalerS10bscaler=&scalerS11blabel=scalerS11b&scalerS11bcolor=%2333a02c&scalerS11byAxisLabel=&scalerS11byAxisMin=&scalerS11byAxisMax=&scalerS11byAxisLog=&scalerS11bscaler= Downstream Halo Counters], [https://epicsweb.jlab.org/wave/?start=2020-07-08+16%3A50%3A02&end=2020-07-08+16%3A55%3A02&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Beam+Currents&fullscreen=false&layoutMode=2&viewerMode=2&pv=IPM2C21A&pv=IPM2C24A&pv=scaler_calc1b&IPM2C21Alabel=IPM2C21A&IPM2C21Acolor=%23a6cee3&IPM2C21AyAxisLabel=Beam+Current+%28nA%29&IPM2C21AyAxisMin=0&IPM2C21AyAxisMax=300&IPM2C21AyAxisLog&IPM2C21Ascaler=&scaler_calc1blabel=Faraday+Cup&scaler_calc1bcolor=%23b2df8a&scaler_calc1byAxisLabel=&scaler_calc1byAxisMin=&scaler_calc1byAxisMax=&scaler_calc1byAxisLog&scaler_calc1bscaler= Beam Currents], [https://epicsweb.jlab.org/wave/?start=2020-08-03+12%3A30%3A57&end=2020-08-03+12%3A35%3A57&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=BPM+Positions+%28Y-Axis+is+mean+%2B%2F-+0.5+mm%29&fullscreen=false&layoutMode=3&viewerMode=2&pv=IPM2C24A.XPOS&pv=IPM2C24A.YPOS&pv=IPM2H01.XPOS&pv=IPM2H01.YPOS&IPM2C24A.XPOSlabel=IPM2C24A.XPOS&IPM2C24A.XPOScolor=%23e31a1c&IPM2C24A.XPOSyAxisLabel=&IPM2C24A.XPOSyAxisMin=-2.0&IPM2C24A.XPOSyAxisMax=+1.0&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=pink&IPM2C24A.YPOSyAxisLabel=&IPM2C24A.YPOSyAxisMin=-2.0&IPM2C24A.YPOSyAxisMax=1.0&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=darkgreen&IPM2H01.XPOSyAxisLabel=&IPM2H01.XPOSyAxisMin=-2.0&IPM2H01.XPOSyAxisMax=1.0&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=lightgreen&IPM2H01.YPOSyAxisLabel=&IPM2H01.YPOSyAxisMin=-2.0&IPM2H01.YPOSyAxisMax=1.0&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler=#a6cee3&IPM2C24A.XPOSyAxisLabel=2C24+X+(mm)&IPM2C24A.XPOSyAxisMin=-1.5&IPM2C24A.XPOSyAxisMax=-0.5&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=%231f78b4&IPM2C24A.YPOSyAxisLabel=2C24+Y+(mm)&IPM2C24A.YPOSyAxisMin=0.3&IPM2C24A.YPOSyAxisMax=1.3&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=pink&IPM2H01.XPOSyAxisLabel=2H01+X+(mm)&IPM2H01.XPOSyAxisMin=-0.6&IPM2H01.XPOSyAxisMax=0.4&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=darkred&IPM2H01.YPOSyAxisLabel=2H01+Y+(mm)&IPM2H01.YPOSyAxisMin=0.4&IPM2H01.YPOSyAxisMax=1.4&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler= BPM Positions] | + | <!--:◊ Some charts are also accessible via web browser: [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Upstream+and+Midstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scaler_cS3b&pv=scaler_cS4b&pv=scaler_cS6b&pv=scaler_cS12b&pv=scaler_cS13b&pv=scaler_cS14b&pv=scaler_cS15b&scaler_cS3blabel=scaler_cS3b&scaler_cS3bcolor=%23a6cee3&scaler_cS3byAxisLabel=Rate++%28Hz%29&scaler_cS3byAxisMin=&scaler_cS3byAxisMax=&scaler_cS3byAxisLog&scaler_cS3bscaler=&start=2020-08-08+09%3A02%3A36&end=2020-08-08+09%3A07%3A36&scaler_cS4blabel=scaler_cS4b&scaler_cS4bcolor=%231f78b4&scaler_cS4byAxisLabel=&scaler_cS4byAxisMin=&scaler_cS4byAxisMax=&scaler_cS4byAxisLog=&scaler_cS4bscaler=&scaler_cS5byAxisLabel=&scaler_cS5byAxisMin=&scaler_cS5byAxisMax=&scaler_cS5byAxisLog=&scaler_cS5bscaler=&scaler_cS6blabel=scaler_cS6b&scaler_cS6bcolor=%2333a02c&scaler_cS6byAxisLabel=&scaler_cS6byAxisMin=&scaler_cS6byAxisMax=&scaler_cS6byAxisLog=&scaler_cS6bscaler=&scaler_cS7byAxisLabel=&scaler_cS7byAxisMin=&scaler_cS7byAxisMax=&scaler_cS7byAxisLog=&scaler_cS7bscaler=&scaler_cS12blabel=scaler_cS12b&scaler_cS12bcolor=%23e31a1c&scaler_cS12byAxisLabel=&scaler_cS12byAxisMin=&scaler_cS12byAxisMax=&scaler_cS12byAxisLog=&scaler_cS12bscaler=&scaler_cS13blabel=scaler_cS13b&scaler_cS13bcolor=%23fdbf6f&scaler_cS13byAxisLabel=&scaler_cS13byAxisMin=&scaler_cS13byAxisMax=&scaler_cS13byAxisLog=&scaler_cS13bscaler=&scaler_cS14blabel=scaler_cS14b&scaler_cS14bcolor=%23ff7f00&scaler_cS14byAxisLabel=&scaler_cS14byAxisMin=&scaler_cS14byAxisMax=&scaler_cS14byAxisLog=&scaler_cS14bscaler=&scaler_cS15blabel=scaler_cS15b&scaler_cS15bcolor=%23cab2d6&scaler_cS15byAxisLabel=&scaler_cS15byAxisMin=&scaler_cS15byAxisMax=&scaler_cS15byAxisLog=&scaler_cS15bscaler= Upstream/Midstream Halo Counters], [https://epicsweb.jlab.org/wave/?myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Downstream+Halo+Counters&fullscreen=false&layoutMode=2&viewerMode=2&pv=scalerS8b&pv=scalerS9b&scalerS8blabel=scalerS8b&scalerS8bcolor=%23a6cee3&scalerS8byAxisLabel=Rate++%28Hz%29&scalerS8byAxisMin=&scalerS8byAxisMax=&scalerS8byAxisLog&scalerS8bscaler=&pv=scalerS10b&pv=scalerS11b&scalerS9blabel=scalerS9b&scalerS9bcolor=%231f78b4&scalerS9byAxisLabel=&scalerS9byAxisMin=&scalerS9byAxisMax=&scalerS9byAxisLog=&scalerS9bscaler=&scalerS10blabel=scalerS10b&scalerS10bcolor=%23b2df8a&scalerS10byAxisLabel=&scalerS10byAxisMin=&scalerS10byAxisMax=&scalerS10byAxisLog=&scalerS10bscaler=&scalerS11blabel=scalerS11b&scalerS11bcolor=%2333a02c&scalerS11byAxisLabel=&scalerS11byAxisMin=&scalerS11byAxisMax=&scalerS11byAxisLog=&scalerS11bscaler= Downstream Halo Counters], [https://epicsweb.jlab.org/wave/?start=2020-07-08+16%3A50%3A02&end=2020-07-08+16%3A55%3A02&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=Beam+Currents&fullscreen=false&layoutMode=2&viewerMode=2&pv=IPM2C21A&pv=IPM2C24A&pv=scaler_calc1b&IPM2C21Alabel=IPM2C21A&IPM2C21Acolor=%23a6cee3&IPM2C21AyAxisLabel=Beam+Current+%28nA%29&IPM2C21AyAxisMin=0&IPM2C21AyAxisMax=300&IPM2C21AyAxisLog&IPM2C21Ascaler=&scaler_calc1blabel=Faraday+Cup&scaler_calc1bcolor=%23b2df8a&scaler_calc1byAxisLabel=&scaler_calc1byAxisMin=&scaler_calc1byAxisMax=&scaler_calc1byAxisLog&scaler_calc1bscaler= Beam Currents], [https://epicsweb.jlab.org/wave/?start=2020-08-03+12%3A30%3A57&end=2020-08-03+12%3A35%3A57&myaDeployment=ops&myaLimit=100000&windowMinutes=30&title=BPM+Positions+%28Y-Axis+is+mean+%2B%2F-+0.5+mm%29&fullscreen=false&layoutMode=3&viewerMode=2&pv=IPM2C24A.XPOS&pv=IPM2C24A.YPOS&pv=IPM2H01.XPOS&pv=IPM2H01.YPOS&IPM2C24A.XPOSlabel=IPM2C24A.XPOS&IPM2C24A.XPOScolor=%23e31a1c&IPM2C24A.XPOSyAxisLabel=&IPM2C24A.XPOSyAxisMin=-2.0&IPM2C24A.XPOSyAxisMax=+1.0&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=pink&IPM2C24A.YPOSyAxisLabel=&IPM2C24A.YPOSyAxisMin=-2.0&IPM2C24A.YPOSyAxisMax=1.0&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=darkgreen&IPM2H01.XPOSyAxisLabel=&IPM2H01.XPOSyAxisMin=-2.0&IPM2H01.XPOSyAxisMax=1.0&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=lightgreen&IPM2H01.YPOSyAxisLabel=&IPM2H01.YPOSyAxisMin=-2.0&IPM2H01.YPOSyAxisMax=1.0&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler=#a6cee3&IPM2C24A.XPOSyAxisLabel=2C24+X+(mm)&IPM2C24A.XPOSyAxisMin=-1.5&IPM2C24A.XPOSyAxisMax=-0.5&IPM2C24A.XPOSyAxisLog&IPM2C24A.XPOSscaler=&IPM2C24A.YPOSlabel=IPM2C24A.YPOS&IPM2C24A.YPOScolor=%231f78b4&IPM2C24A.YPOSyAxisLabel=2C24+Y+(mm)&IPM2C24A.YPOSyAxisMin=0.3&IPM2C24A.YPOSyAxisMax=1.3&IPM2C24A.YPOSyAxisLog&IPM2C24A.YPOSscaler=&IPM2H01.XPOSlabel=IPM2H01.XPOS&IPM2H01.XPOScolor=pink&IPM2H01.XPOSyAxisLabel=2H01+X+(mm)&IPM2H01.XPOSyAxisMin=-0.6&IPM2H01.XPOSyAxisMax=0.4&IPM2H01.XPOSyAxisLog&IPM2H01.XPOSscaler=&IPM2H01.YPOSlabel=IPM2H01.YPOS&IPM2H01.YPOScolor=darkred&IPM2H01.YPOSyAxisLabel=2H01+Y+(mm)&IPM2H01.YPOSyAxisMin=0.4&IPM2H01.YPOSyAxisMax=1.4&IPM2H01.YPOSyAxisLog&IPM2H01.YPOSscaler= BPM Positions]--> |
| | | |
| | | |
| | | |
− | = Monitoring = | + | <!--= Monitoring =--> |
| <!--####################################### MONITORING ################################################--> | | <!--####################################### MONITORING ################################################--> |
− | {| {{TableStyle1}} | + | <!--{| {{TableStyle1}} |
| | valign=top | | | | valign=top | |
| === Webcams === | | === Webcams === |
Line 2,199: |
Line 606: |
| === Data Quality === | | === Data Quality === |
| * MON12 histograms: reference and most recent uploads | | * MON12 histograms: reference and most recent uploads |
− | ** [https://clas12mon.jlab.org/mon12/histograms/?reference=4274417 run 20085] | + | ** [https://clas12mon.jlab.org/mon12/histograms/?reference=4295017 run 20367] |
| * [https://github.com/JeffersonLab/caos/tree/main#readme clas12mltrack]: real-time reconstructed vertices & various event topologies | | * [https://github.com/JeffersonLab/caos/tree/main#readme clas12mltrack]: real-time reconstructed vertices & various event topologies |
| * [https://clasweb.jlab.org/clas12online/timelines/rg-e/RGE2024_progress_all.html Total Charge on Target Plot] | | * [https://clasweb.jlab.org/clas12online/timelines/rg-e/RGE2024_progress_all.html Total Charge on Target Plot] |
| * [https://clasweb.jlab.org/clas12online/timelines/rg-e/RGE2024_progress_all.pdf Total Charge on Target Plot pdf version] | | * [https://clasweb.jlab.org/clas12online/timelines/rg-e/RGE2024_progress_all.pdf Total Charge on Target Plot pdf version] |
| * [https://clasweb.jlab.org/hydra/dashboard2.html Hydra] (CUE Login) | | * [https://clasweb.jlab.org/hydra/dashboard2.html Hydra] (CUE Login) |
− | |} | + | |}--> |
| | | |
| | | |
− | = Important Links = | + | <!--= Important Links =--> |
| <!--####################################### USEFUL LINKS ################################################--> | | <!--####################################### USEFUL LINKS ################################################--> |
− | {| {{TableStyle1}} | + | <!--{| {{TableStyle1}} |
| | valign=top | | | | valign=top | |
| ===Hall-B=== | | ===Hall-B=== |
Line 2,228: |
Line 635: |
| | valign=top | | | | valign=top | |
| ===ZOOM Meetings=== | | ===ZOOM Meetings=== |
− | * 07:45 [https://jlab-org.zoomgov.com/j/1611456010?pwd=d2RJWTJQRDM0ZkNaZ1dpTmtLWDAwQT09 RC/PD Morning Meeting, 9:00AM weekends] | + | * [https://jlab-org.zoomgov.com/j/1611740648?pwd=aUlybTg2VExQL1FJN0VSbnNRaEc1dz09 RC/PD 7:45 Morning Meeting] |
− | * 08:00 [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 MCC/OPS Morning and Wednesday 1:30 Meeting] | + | * [https://jlab-org.zoomgov.com/j/1601304841?pwd=Z1RIOVVUdkdXL2R2LzREZUNOUlh1dz09 MCC/OPS 8:00 MTThF and 1:30 Wednesday Meeting] |
| * [https://logbooks.jlab.org/entry/4000274 See also this logbook entry] | | * [https://logbooks.jlab.org/entry/4000274 See also this logbook entry] |
| * [https://jlab-org.zoomgov.com/j/1605705819 Daily Hall B Run Coordinator Meeting] | | * [https://jlab-org.zoomgov.com/j/1605705819 Daily Hall B Run Coordinator Meeting] |
| * [https://logbooks.jlab.org/entry/4158818 Hall B Remote Shifts & Counting House] | | * [https://logbooks.jlab.org/entry/4158818 Hall B Remote Shifts & Counting House] |
− | |} | + | |}--> |
| | | |
| | | |
− | <headertabs/> | + | <!--headertabs/> |
| __NOEDITSECTION__ | | __NOEDITSECTION__ |
| __NOTOC__ | | __NOTOC__ |
Line 2,242: |
Line 649: |
| | valign=top style="text-align:center"| | | | valign=top style="text-align:center"| |
| [[Image:clas12design.png|500px]] | | [[Image:clas12design.png|500px]] |
− | |} | + | |}--> |