Difference between revisions of "Run Group F"
Jump to navigation
Jump to search
(42 intermediate revisions by 4 users not shown) | |||
Line 12: | Line 12: | ||
'''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf Beam Time Accounting User Guide]'''. | '''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf Beam Time Accounting User Guide]'''. | ||
<!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation]=== --> | <!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation]=== --> | ||
+ | ===[https://www.jlab.org/Hall-B/run-web/rgf/ESAD_HallB-CLAS12_rgF.pdf ESAD], [https://www.jlab.org/Hall-B/run-web/rgf/COO_HallB-CLAS12_rgF.pdf COO], [https://www.jlab.org/Hall-B/run-web/rgf/RSAD_HallB-CLAS12_rgF.pdf RSAD], [https://www.jlab.org/div_dept/train/SAF111/Hall%20B%20worker%20Safety%20Training%20%28SAF111%29%20%2008%2001-12-1.pdf ERG] === | ||
+ | ===[https://www.jlab.org/Hall-B/run-web/rgf/RTPC_OSP.pdf OSP for Radial Time Projection Chamber]=== | ||
+ | ===[https://www.jlab.org/Hall-B/run-web/rgf/bonus12_gas_target_osp_97803.pdf OSP for BONUS12 gas target system]=== | ||
| valign=top | | | valign=top | | ||
Line 120: | Line 123: | ||
− | == RC: | + | == RC: Mohammad Hattawy == |
=== RC phone: === | === RC phone: === | ||
Line 126: | Line 129: | ||
* 9 757-575-7540 from Counting Room. | * 9 757-575-7540 from Counting Room. | ||
* If you can't reach the RC on the RC phone, use the personal phone numbers (Mohammad: (423) 596-8352, Sebastian: (757) 639-6640) | * If you can't reach the RC on the RC phone, use the personal phone numbers (Mohammad: (423) 596-8352, Sebastian: (757) 639-6640) | ||
− | |||
* RC meeting held at 12 pm online. Bluejeans 757 683 5804 | * RC meeting held at 12 pm online. Bluejeans 757 683 5804 | ||
− | + | * Get the number of events from SQL --> [http://clasweb.jlab.org/rcdb RCDB] | |
− | * | ||
Line 137: | Line 138: | ||
== NEW SHIFT INFORMATION - PLEASE READ == | == NEW SHIFT INFORMATION - PLEASE READ == | ||
− | Due to travel restrictions, only local people will be able to come to Jefferson Lab for their shifts. To deal with this situation, Jefferson Lab leadership has developed a new [https://userweb.jlab.org/~kuhn/BONuS12/Documents/shift-policy_20200317.docx POLICY] that requires only an expert shift taker during Day and Swing shifts (Owl shifts will still be covered by 2 people). There will be remote backup | + | Due to travel restrictions, only local people will be able to come to Jefferson Lab for their shifts. To deal with this situation, Jefferson Lab leadership has developed a new [https://userweb.jlab.org/~kuhn/BONuS12/Documents/shift-policy_20200317.docx POLICY] that requires only an expert shift taker during Day and Swing shifts (Owl shifts will still be covered by 2 people). There will be remote backup ("Ghost Shifts") for some of the worker shifts during Day/Swing - '''please read the instructions under the "Remote Shifts" tab and make sure that Bluejeans is properly connected (Screen share and audio)'''. All counting houses have been equipped with a direct camera feed so that shift takers for ANY hall can monitor the counting houses of Hall B and Hall D when only 1 person is present. Shift Experts will carry a cell phone that can be used to call in help. IF YOU ARE ALONE ON SHIFT, you may not go into the Hall - call the relevant experts instead. Shift experts during Day and Swing are expected, in addition to their regular duties, to also check monitoring histograms and CED and log them (as well as standard screen shots) to the logbook, and to respond to any alarms, as well as fill out shift checklists. These new rules take effect on Tuesday, March 24. |
Starting immediately, please follow these rules: Keep a distance of 6 ft from all other people AT ALL TIMES. In particular, expert and worker (when both present) should sit 6 feet apart, facing in different directions. In addition, only the RC OR an RTPC expert should be inside the counting house B at any time - a maximum room occupancy of THREE has to be obeyed at all times. The RC, PDL and shift expert have the authority to ask non-essential people to leave if overcrowding occurs. Any work that requires 2 people to work in closer proximity than 6' must be first approved. | Starting immediately, please follow these rules: Keep a distance of 6 ft from all other people AT ALL TIMES. In particular, expert and worker (when both present) should sit 6 feet apart, facing in different directions. In addition, only the RC OR an RTPC expert should be inside the counting house B at any time - a maximum room occupancy of THREE has to be obeyed at all times. The RC, PDL and shift expert have the authority to ask non-essential people to leave if overcrowding occurs. Any work that requires 2 people to work in closer proximity than 6' must be first approved. | ||
− | At present, we expect the experimental run to continue until '''September 21, 2020'''. Obviously, this puts extra burden on many people, and we are grateful especially for those local volunteers who have signed up for shifts. | + | At present, we expect the experimental run to continue until '''September 21, 2020'''. Obviously, this puts extra burden on many people, and we are grateful especially for those local volunteers who have signed up for shifts.Please also read the relevant information on COVID-19 and MEDCON5 operations at Jefferson Lab: [https://jlab.servicenowservices.com/cv19?id=cv19_index] |
================================================================================================================================== | ================================================================================================================================== | ||
Line 152: | Line 153: | ||
===<font color=black>There will be an audible Beamline alarm when the half-wave plate (HWP) state changes. Please end the ongoing run and start a new run.</font>=== | ===<font color=black>There will be an audible Beamline alarm when the half-wave plate (HWP) state changes. Please end the ongoing run and start a new run.</font>=== | ||
− | ===<font color=blue>'' 2. For every run (~ | + | ===<font color=blue>'' 2. For every run (~15-20 M events)''</font>=== |
# In the '''begin run dialog''', enter the requested '''beam current''', the '''state of the half-wave plate (IN or OUT)''' and any conditions changed since the last run (target, B-fields, HVs, DAQ config, trigger, ...). In the end run dialog, check boxes ("junk" etc.) and add to the dialog any significant changes during the run. | # In the '''begin run dialog''', enter the requested '''beam current''', the '''state of the half-wave plate (IN or OUT)''' and any conditions changed since the last run (target, B-fields, HVs, DAQ config, trigger, ...). In the end run dialog, check boxes ("junk" etc.) and add to the dialog any significant changes during the run. | ||
# *) Near the beginning of the run, submit the following screenshots (can be all in one elog entry) '''while beam is on'''. Sample plots for reference: | # *) Near the beginning of the run, submit the following screenshots (can be all in one elog entry) '''while beam is on'''. Sample plots for reference: | ||
Line 188: | Line 189: | ||
== <font color=blue>'''B. Run Plan'''</font> (see also [https://userweb.jlab.org/~kuhn/BONuS12/Documents/RunPlan.pdf initial run plan]) == | == <font color=blue>'''B. Run Plan'''</font> (see also [https://userweb.jlab.org/~kuhn/BONuS12/Documents/RunPlan.pdf initial run plan]) == | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | * Collect 30M on H2 | |
− | + | * Call Mohammad to set the target to empty | |
+ | * continue taking data on empty target setting till 7:00AM on Monday, Sep 21st. | ||
<b>DAQ config: PROD66 </b>, | <b>DAQ config: PROD66 </b>, | ||
− | <b>Trigger file: | + | <b>Trigger file: rgf_inbending_v4_2.trg (.cnf)</b> |
− | # Continue taking data | + | # Continue taking data with 270 nA beam current (@2C24). '''NOTE:''' This is 280 nA on the SLM, which means we have to ask MCC for 270 nA on 2C24 (which is what they see). |
# <font color=red> Please write the target pressure and comments in the dialogue box when starting/stopping a run </font> | # <font color=red> Please write the target pressure and comments in the dialogue box when starting/stopping a run </font> | ||
# Start a run and check that live time is above 85%. If not decrease current and log it. | # Start a run and check that live time is above 85%. If not decrease current and log it. | ||
− | # Restart a new run every | + | # Restart a new run every (15-20)M events (wait till beam trips). '''END A RUN''' if beam will be off > 20 min, RTPC HV trip, or '''whenever half-wave plate is changed'''! |
− | # Submit the list of screenshots at the beginning and at the | + | # Submit the list of screenshots + clas12mon +ced at the beginning and at after the first 10M events in every run. |
# Keep BTA (beam time accounting) up to date, including reasons for any entries with experiment not ready. | # Keep BTA (beam time accounting) up to date, including reasons for any entries with experiment not ready. | ||
# <b> When checking the ECAL response, make sure to look at the histograms for each sector by using the sector buttons at the bottom of the clas12mon window - if adcecal* or/and adcpcal* ROC crashes, there will be no alarm and the histograms are the way to notice this issue. | # <b> When checking the ECAL response, make sure to look at the histograms for each sector by using the sector buttons at the bottom of the clas12mon window - if adcecal* or/and adcpcal* ROC crashes, there will be no alarm and the histograms are the way to notice this issue. | ||
Line 213: | Line 210: | ||
# b. if the run did not end correctly or if any ROCs had to be rebooted:-> "configure", "download", "prestart", "go"<br> | # b. if the run did not end correctly or if any ROCs had to be rebooted:-> "configure", "download", "prestart", "go"<br> | ||
+ | === Plan for Monday Morning, Sep 21st === | ||
+ | # 07:00 : The beam will be taken away for some MCC studies. Gagik, will confirm with MCC that the Hall goes to Controlled Access. | ||
+ | # 07:00 to 8:00: Gagik will call Eugene to ramp down the torus and ramp the solenoid to 1.5T. | ||
+ | # 07:00- 08:00: Gagik can turn off HV on the following detectors ONLY (LTCC, HTCC, DC, RICH, FMT, FTC, FTH) | ||
+ | # 08:00: Gagik leaves the counting house and the BONuS team (Jiwan and Sebastian) will join to do final cosmic tests. | ||
+ | # Before 12:00: the solenoid be totally ramped down. the bonus team will be in contact with Eugene. | ||
+ | # 12:00: The bonus team will turn off HV on ECAL, PCAL, and CND. | ||
+ | # FTOF and CTOF must be left turned ON. | ||
================================================================================================================================== | ================================================================================================================================== | ||
Line 219: | Line 224: | ||
===* Establish beam in the Hall ( CALL RC )=== | ===* Establish beam in the Hall ( CALL RC )=== | ||
− | |||
# ALL the detectors must be off. Don't forget the FT and RTPC HV (separate GUIs). | # ALL the detectors must be off. Don't forget the FT and RTPC HV (separate GUIs). | ||
# Ask MCC to energize the tagger magnet. | # Ask MCC to energize the tagger magnet. | ||
Line 228: | Line 232: | ||
# Set alarms and interlocks. | # Set alarms and interlocks. | ||
# Call the MCC and tell them that the beam is good and must keep the beam current at 5 nA. | # Call the MCC and tell them that the beam is good and must keep the beam current at 5 nA. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<b> Default solenoid current and B field </b> 1800 A (~3.78 T) | <b> Default solenoid current and B field </b> 1800 A (~3.78 T) | ||
<b> Nominal Beam Positions </b> | <b> Nominal Beam Positions </b> | ||
− | ''(last update | + | ''(last update Sep 10th, 2020 @ 23:50 PM)'' |
− | *2H01, X: +0. | + | *2H01, X: +0.7 mm, Y: -1.6 mm |
− | *2C24, X: - | + | *2C24, X: -2.0 mm, Y: -1.0 mm |
*2C21, X: -0.4 mm, Y: 0.3 mm | *2C21, X: -0.4 mm, Y: 0.3 mm | ||
<b> FSD Thresholds </b> | <b> FSD Thresholds </b> | ||
− | * Upstream: 2, | + | * Upstream: 2,600 Hz |
* Midstream: 2,000 Hz | * Midstream: 2,000 Hz | ||
* Downstream: 500,000 Hz | * Downstream: 500,000 Hz | ||
− | * BOM: | + | * BOM: 7,000 Hz |
<b> FSD Dwell (Integration) Time </b> | <b> FSD Dwell (Integration) Time </b> | ||
Line 461: | Line 452: | ||
* Audio for the bluejeans session goes through the phone, 269-5247. This is the phone attached on the second row of tables (former RC station), behind the shift expert station. | * Audio for the bluejeans session goes through the phone, 269-5247. This is the phone attached on the second row of tables (former RC station), behind the shift expert station. | ||
** DO NOT HANG UP or MUTE the phone, if you have to mute then do not forget to unmute. | ** DO NOT HANG UP or MUTE the phone, if you have to mute then do not forget to unmute. | ||
− | ** About every 6 hours the bluejeans will disconnect the phone if this happens, use the microphone tab in the bluejeans window and choose "Switch to phone audio" then select "Call me" and give the phone number, 757 269 5247. Once you are connected, you have to press "'''*4'''" on the phone to unmute yourself. | + | ** CHECK AT THE BEGINNING OF EACH SHIFT: About every 6 hours the bluejeans will disconnect the phone if this happens, use the microphone tab in the bluejeans window and choose "Switch to phone audio" then select "Call me" and give the phone number, 757 269 5247. Once you are connected, you have to press "'''*4'''" on the phone to unmute yourself. |
<headertabs/> | <headertabs/> |