Difference between revisions of "AI Optimized Polarization"
Jump to navigation
Jump to search
(16 intermediate revisions by 4 users not shown) | |||
Line 22: | Line 22: | ||
!Slides | !Slides | ||
!Proceedings | !Proceedings | ||
+ | |- | ||
+ | | 2024-12-05 | ||
+ | | David L. | ||
+ | | PI Exchange (Washington D.C.) | ||
+ | | [https://docs.google.com/presentation/d/1zmETvW379wcHlj54Mdyc8iuKpfaNbexEMXN9y3VUjCA/edit?usp=sharing slides] | ||
+ | |- | ||
+ | |2024-12-13 | ||
+ | |Patrick Moran | ||
+ | |Italian Institute of Health Friday seminar | ||
+ | |[https://wiki.jlab.org/epsciwiki/images/3/38/ISS_AIOP_Talk_12_13_24.pdf slides] | ||
|} | |} | ||
Line 47: | Line 57: | ||
* Victoria Lagerquist's thesis: [https://www.jlab.org/Hall-B/general/thesis/VLagerquist_thesis.pdf Design and Construction of a Longitudinally Polarized Solid Nuclear Target for CLAS12] | * Victoria Lagerquist's thesis: [https://www.jlab.org/Hall-B/general/thesis/VLagerquist_thesis.pdf Design and Construction of a Longitudinally Polarized Solid Nuclear Target for CLAS12] | ||
* Noémie's polarization extracted from elastic scattering: [https://clasweb.jlab.org/wiki/index.php/Elastic_Analysis_for_PbPt_Extraction Elastic Analysis for PbPt extraction] | * Noémie's polarization extracted from elastic scattering: [https://clasweb.jlab.org/wiki/index.php/Elastic_Analysis_for_PbPt_Extraction Elastic Analysis for PbPt extraction] | ||
+ | |||
+ | == Education/Outreach == | ||
+ | * [https://www.jlab.org/conference/hugs2024 HUGS] | ||
+ | ** [https://indico.jlab.org/event/854/timetable/#all.detailed Timetable] (see talks by Britton, Gavalian/Jeske, and Lersch) | ||
+ | * [Middle School Data Science event] | ||
== Resources == | == Resources == | ||
Line 67: | Line 82: | ||
| | | | ||
|} | |} | ||
+ | |||
+ | == List of observed photon beam coherent peak shifts to take a look at == | ||
+ | * March 30 2018 - before and after the repositioning of the diamond. | ||
+ | * before March 30, last run before the beam went down and first run after it came back, unless Hovanes realigned | ||
+ | * https://logbooks.jlab.org/entry/3761564 - look at difference between reference and observed peak | ||
+ | * [https://halldweb.jlab.org/wiki/index.php/RunPeriod-2022-05_Validation#Launch_v27 CPP - several instances of wild beam energy shifts reported] NB nominal position was around 6 GeV not 9 GeV | ||
+ | * [https://halldweb.jlab.org/gluex_demon/demon.html?RunPeriod=RunPeriod-2017-01&Version=55&Detector=Photon_beam#photons_ps_e Demon's plots] show a variety of interesting coherent peak positions near the start of 2017 | ||
+ | * [https://logbooks.jlab.org/entry/4006983 logbook entry] Cristiano nudged 6-25-22 00:39 run 100667 | ||
+ | * [https://logbooks.jlab.org/entry/3515533 logbook entry] Naomi nudged Jan 17 2018 run ? | ||
+ | * [https://logbooks.jlab.org/entry/3798502 logbook] example of bad fit in the expert? part of the gui | ||
+ | * [https://logbooks.jlab.org/entry/3516243 logbook] nudged the diamond after switching to perp, and then the fit was having issues (because of a bad uscope channel, I think) | ||
+ | * [https://logbooks.jlab.org/entry/3522232 logbook] 27 Jan 2018 Simon had trouble nudging the diamond, hit the button but nothing happened, found that the microscope scaler display was not updating | ||
+ | * [https://logbooks.jlab.org/entry/4029399 logbook] 15 Aug 2022 Simon & Joerg corrected edge position for 101600 | ||
+ | * [https://logbooks.jlab.org/entry/3520871 logbook] Simon, 25 Jan 2018 | ||
+ | * [https://logbooks.jlab.org/entry/3457510 logbook] Simon, 10 Feb 2018 (only the 'after' pic but he said he moved it 70MeV) | ||
+ | |||
+ | == Shopping list == | ||
+ | |||
+ | * date | ||
+ | * run number | ||
+ | * radiator id | ||
+ | * goniometer angles | ||
+ | * e beam position & current | ||
+ | * coherent edge position and width. It looked like the width changed abruptly in the March 30 incident. | ||
+ | |||
+ | * PS scalers | ||
+ | * TAGM & H scalers | ||
+ | |||
+ | * How stable is the PS acceptance, does the PS E histogram from AMO runs change with time? | ||
+ | * Does the PS E histo change between one storing of the TAGM AMO reference and the next? | ||
+ | |||
+ | |||
+ | * myaplot config files and plots for some of the above (edge & width), (edge & width & beam position) |
Latest revision as of 00:34, 17 December 2024
Meetings
Repositories
Raw data storage
- Photon Source: /work/halld3/home/AIOP/source/
- Target: /work/halld3/home/AIOP/target/
Presentations/Papers
Date | Presenter | Event | Slides | Proceedings |
---|---|---|---|---|
2024-12-05 | David L. | PI Exchange (Washington D.C.) | slides | |
2024-12-13 | Patrick Moran | Italian Institute of Health Friday seminar | slides |
Experimental Data Locations
Run Group C, 2022-23
- /group/poltar/HallB/RGC
- Proton data in directory data-p
- Deuteron data in directory data-d
SANE, 2009
- /group/poltar/HallC/SANE
- all_data.csv contains NMR system meta-data
- epics_export.txt contains EPICS meta-data
- events folder contains online data with raw NMR signals
- Several ipynb files give examples of reading the above files
EG4, 2006
- /group/poltar/HallB/EG4/eg4_nmr_clean
- Data is in binary format. I'll provide a script to convert to text.
Documentation
Target
- Victoria Lagerquist's thesis: Design and Construction of a Longitudinally Polarized Solid Nuclear Target for CLAS12
- Noémie's polarization extracted from elastic scattering: Elastic Analysis for PbPt extraction
Education/Outreach
- HUGS
- Timetable (see talks by Britton, Gavalian/Jeske, and Lersch)
- [Middle School Data Science event]
Resources
Title/Link | Type | Notes |
---|---|---|
The Stonehenge Technique. A new method for aligning coherent bremsstrahlung radiators (NIM, arXiv) | Paper | |
Coherent Bremsstrahlun of Electrons in Crystals(GlueX DocDB) | Paper | |
Development of Novel Attention-Aware Deep Learning Models and Their Applications in Computer Vision and Dynamical System Calibration | Thesis |
List of observed photon beam coherent peak shifts to take a look at
- March 30 2018 - before and after the repositioning of the diamond.
- before March 30, last run before the beam went down and first run after it came back, unless Hovanes realigned
- https://logbooks.jlab.org/entry/3761564 - look at difference between reference and observed peak
- CPP - several instances of wild beam energy shifts reported NB nominal position was around 6 GeV not 9 GeV
- Demon's plots show a variety of interesting coherent peak positions near the start of 2017
- logbook entry Cristiano nudged 6-25-22 00:39 run 100667
- logbook entry Naomi nudged Jan 17 2018 run ?
- logbook example of bad fit in the expert? part of the gui
- logbook nudged the diamond after switching to perp, and then the fit was having issues (because of a bad uscope channel, I think)
- logbook 27 Jan 2018 Simon had trouble nudging the diamond, hit the button but nothing happened, found that the microscope scaler display was not updating
- logbook 15 Aug 2022 Simon & Joerg corrected edge position for 101600
- logbook Simon, 25 Jan 2018
- logbook Simon, 10 Feb 2018 (only the 'after' pic but he said he moved it 70MeV)
Shopping list
- date
- run number
- radiator id
- goniometer angles
- e beam position & current
- coherent edge position and width. It looked like the width changed abruptly in the March 30 incident.
- PS scalers
- TAGM & H scalers
- How stable is the PS acceptance, does the PS E histogram from AMO runs change with time?
- Does the PS E histo change between one storing of the TAGM AMO reference and the next?
- myaplot config files and plots for some of the above (edge & width), (edge & width & beam position)