Starting CODA From Scratch

You do not need to do this routinely - only if you are starting from a fresh login or after a computer crash. Log in a a-onl account on adaql2 ( check with Run Coordinator in case you don't know the password )

(Contact: Bob Michaels)

Power cycling Fastbus crates

Right HRS only : go in Tools screen -> Crate Resets -> Lower Fastbus AC

This will power cycle all 3 ROCs of the fastbus

Same for Left HRS but it will get stuck off. To get the Fastbus back on login into hareboot2 from an accelerator account or hlal00 and power cycle iocha4 which is on port 1

Reboot crates

On one workspace you will see six xterms with names of the crates in the title, e.g. "ROC4--hallasfi4--hatsv40-port6". From each of the six xterms, you should telnet into the appropriate RS232 interface, e.g. for the above, "telnet hatsv40 2006" (if the prompt in the xterm is "->", it is already connected). The "hallasfi4" is the internet name of the crate's cpu.

If the xterms are missing, type "setupxterms".

From these xterms, you reboot by typing "ctrl-X". Yes, you hold down the Ctrl key, then hit X. You can also type reboot but "ctrl-X" is better. You can also reboot from the crate resets GUI on HA Tools.

To power cycle the DVCS crates, type crateOff in a terminal in logged as a-onl and after crateON to turn both ROC17 and ROC18 back on.

For full details about the Hall A DAQ (including reboot procedures) see This or This

|