HRS Optics Run

From Tritium Experiments Group
Jump to navigation Jump to search

Back to Installation and Commissioning

  1. Multifoil target:
    1. one DIS run without sieve for y-target calibration
    2. sieve on, take a long DIS run for theta, phi calibration
  2. Hydrogen target: elastic peak check (move RHRS to a larger angle), and delta scan at +-2%, +-4% of elastic peak

Optics Study Page (Back to Tritium-Main) Back to Commissioning Page

Run Info

LHRS optics runs

Step L1: Procedure with Sieve-slit

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Multi-foil carbon Yes Off
15cm LH2 Yes 2 x 2 mm2
Multi-foil carbon Yes Off

Step L2: Delta Scan with Proton Elastic (with sieve slit)

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-4%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=0%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+4%;

Step L3: Dummy Target Runs (with sieve slit)

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
15cm dummy Yes 2 x 2 mm2 +4% delta scan setting

Step L4: Proton Elastic Kinematics

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Single-foil carbon No Off
15cm dummy No 2 x 2 mm2
15cm LH2 No 2 x 2 mm2


RHRS optics runs

Step R1: Procedure with Sieve-slit

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Multi-foil carbon Yes Off
15cm LH2 Yes 2 x 2 mm2
Multi-foil carbon Yes Off

Step R2: Delta Scan with Proton Elastic (with sieve slit)

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-4%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=-2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=0%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+2%;
15cm LH2 Yes 2 x 2 mm2 Delta scan ΔP=+4%;

Step R3: Dummy Target Runs (with sieve slit)

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
15cm dummy Yes 2 x 2 mm2 +4% delta scan setting

Step R4: Proton Elastic Kinematics

Run number Target Sieve Raster Ebeam [GeV] P0 [GeV/c] θe [deg] Comment
Single-foil carbon No Off
15cm dummy No 2 x 2 mm2
15cm LH2 No 2 x 2 mm2