Here

From Tritium Experiments Group
Jump to navigation Jump to search

Back to Tritium-Main Back to How to Back to Third Person

Direct link to the entire repository of information.

When Running CODA it is all crucial to control the prescales. Find how to control these here:

Setting prescale factor for the HRS only (updated 11/03)

   For Left HRS:
 *   log in as adaq on adaq1 machine
 *   type "prescaleL &" to open the GUI
 *   set the desired prescale factors and click "Save" and Exit 
   For Right HRS:
 *   log in as "adaq" on "adaq2" machine
 *   type "prescaleR &" to open the GUI
 *   set the desired prescale factors and click "Save" and Exit 
   Definition of triggers:(Proposed for Argon- 02/07/17)
       T1 = L-arm s0 && s2 && Shower
       T2 = L-arm (s0 || s2) && (Cherenov||Shower)
       T3 = R-arm s0 && s2 
       T4 = R-arm (s0 || s2) && !(Cherenov||Shower)
       T5 = T1 && T3
       T6 = T2 && T4
       T7 = L-arm EDTM trigger
       T8 = 103.7 kHz pulser (for LHRS), 1.024 kHz (for RHRS)
       T9 =