Setting prescale factor for the HRS only (updated 11/03)

   For Left HRS:
 *   log in as adaq on adaq1 machine
 *   type "prescaleL &" to open the GUI
 *   set the desired prescale factors and click "Save" and Exit 
   For Right HRS:
 *   log in as "adaq" on "adaq2" machine
 *   type "prescaleR &" to open the GUI
 *   set the desired prescale factors and click "Save" and Exit 
   Definition of triggers:(Proposed for Argon- 02/07/17)
       T1 = L-arm s0 && s2 && Shower
       T2 = L-arm (s0 || s2) && (Cherenov||Shower)
       T3 = R-arm s0 && s2 
       T4 = R-arm (s0 || s2) && !(Cherenov||Shower)
       T5 = T1 && T3
       T6 = T2 && T4
       T7 = L-arm EDTM trigger
       T8 = 103.7 kHz pulser (for LHRS), 1.024 kHz (for RHRS)
       T9 =