Difference between revisions of "Run Group B"

From clas12-run
Jump to navigation Jump to search
 
(427 intermediate revisions by 16 users not shown)
Line 11: Line 11:
 
* See guidance for BTA in '''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf Beam Time Accounting User Guide]'''.
 
* See guidance for BTA in '''[https://accwiki.acc.jlab.org/pub/SWDocs/BeamTimeAccounting/Machine_Time_Accounting_User_Guide.pdf Beam Time Accounting User Guide]'''.
 
<!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation]=== -->
 
<!-- ===[https://clasweb.jlab.org/wiki/index.php/CLAS12_OPS_Doc#CLAS12_Operations_Documentation Operations Documentation]=== -->
 +
===[https://www.jlab.org/Hall-B/run-web/rgb/ESAD_HallB-CLAS12_rgB.pdf ESAD], [https://www.jlab.org/Hall-B/run-web/rgb/COO_HallB-CLAS12_rgB.pdf COO], [https://www.jlab.org/Hall-B/run-web/rgb/RSAD_HallB-CLAS12_rgB.pdf RSAD], [https://www.jlab.org/div_dept/train/SAF111/Hall%20B%20worker%20Safety%20Training%20%28SAF111%29%20%2008%2001-12-1.pdf ERG] ===
  
 
| valign=top |
 
| valign=top |
Line 18: Line 19:
 
* [https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf CND]
 
* [https://clasweb.jlab.org/wiki/images/9/97/Ops_manual_cnd.pdf CND]
 
* [https://clasweb.jlab.org/wiki/images/c/c1/Shift_Worker_Manual_January_2018.pdf Cryo-Target]
 
* [https://clasweb.jlab.org/wiki/images/c/c1/Shift_Worker_Manual_January_2018.pdf Cryo-Target]
* [https://clasweb.jlab.org/wiki/images/0/0f/Ctof_manual.pdf CTOF]
+
* [https://www.jlab.org/Hall-B/ctof/notes/ctof_manual.pdf CTOF]
 
* [https://clasweb.jlab.org/wiki/images/a/ab/Opman_master.pdf DAQ]
 
* [https://clasweb.jlab.org/wiki/images/a/ab/Opman_master.pdf DAQ]
 
* [https://clasweb.jlab.org/wiki/images/b/b2/Drift-chamber-operating-procedure.pdf DC]
 
* [https://clasweb.jlab.org/wiki/images/b/b2/Drift-chamber-operating-procedure.pdf DC]
 
* [https://clasweb.jlab.org/wiki/images/a/a2/Ec_manual.pdf ECAL]
 
* [https://clasweb.jlab.org/wiki/images/a/a2/Ec_manual.pdf ECAL]
 
* [https://clasweb.jlab.org/wiki/images/3/3b/FT-Manual.pdf FT]
 
* [https://clasweb.jlab.org/wiki/images/3/3b/FT-Manual.pdf FT]
* [https://clasweb.jlab.org/wiki/images/b/b0/Ftof_manual.pdf  FTOF]
+
* [https://www.jlab.org/Hall-B/ftof/notes/ftof_manual.pdf  FTOF]
 
* [https://clasweb.jlab.org/wiki/images/f/f1/HTCC_MANUAL.pdf HTCC]
 
* [https://clasweb.jlab.org/wiki/images/f/f1/HTCC_MANUAL.pdf HTCC]
 
* [https://wiki.jlab.org/clas12-run/images/d/d2/Ltcc_manual.pdf LTCC]
 
* [https://wiki.jlab.org/clas12-run/images/d/d2/Ltcc_manual.pdf LTCC]
Line 31: Line 32:
 
* [[Media:clas12controls_shift.pdf|Slow Controls]]
 
* [[Media:clas12controls_shift.pdf|Slow Controls]]
 
* [https://clasweb.jlab.org/wiki/images/d/dc/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf Solenoid Power-Up and Power-Down Procedure]
 
* [https://clasweb.jlab.org/wiki/images/d/dc/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf Solenoid Power-Up and Power-Down Procedure]
* [https://clasweb.jlab.org/wiki/images/9/96/Svt_operation_manual_v1_1.pdf SVT]
+
* [[Media:Svt_operation_manual_v1_7.pdf | SVT]] To switch on SVT see [https://logbooks.jlab.org/files/2018/10/3615766/svt_problem_solving_0.pdf SVT short]
 
* [https://clasweb.jlab.org/wiki/images/d/d6/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf Torus Power-Up and Power-Down Procedure]
 
* [https://clasweb.jlab.org/wiki/images/d/d6/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf Torus Power-Up and Power-Down Procedure]
  
Line 53: Line 54:
 
| valign=top |
 
| valign=top |
 
===RC schedule===
 
===RC schedule===
* Jan 26 - Feb 6: S. Niccolai
+
* Nov 20 - Nov 27: S. Stepanyan
* Feb 6 - Feb 13: Y. Ilieva
+
* Nov 27 - Dec 4: M. Contalbrigo
* Feb 13 - Feb 20: S. Stepanyan
+
* Dec 4 - Dec 11: D. Sokhan
* Feb 20 - Feb 27: F. Hauenstein
+
* Dec 11 - Dec 18: S. Niccolai
* Feb 27 - Mar 6: S. Niccolai
+
* Dec 18 - Dec 20 S. Stepanyan
* Mar 6 to Mar 12: J. Gilfoyle  
+
* Jan 7 - Jan 15: J. Gilfoyle
* Mar 12 to Mar 19: V. Kubarowsky
+
* Jan 15 - Jan 22: F. Hauenstein /W. Phelps
 +
* Jan 22 - Jan 30: B. McKinnon
  
 
</font>
 
</font>
Line 70: Line 72:
 
[https://wiki.jlab.org/clas12-run/index.php?title=Template:PhoneNumbers&action=edit Click Here]  to edit Phone Numbers.  Note, you then also have to [https://wiki.jlab.org/clas12-run/index.php?title=Run_Group_B&action=edit&section=11 edit this page] to force a refresh.
 
[https://wiki.jlab.org/clas12-run/index.php?title=Template:PhoneNumbers&action=edit Click Here]  to edit Phone Numbers.  Note, you then also have to [https://wiki.jlab.org/clas12-run/index.php?title=Run_Group_B&action=edit&section=11 edit this page] to force a refresh.
  
<!-- JUST MODIFY AND SAVE ANYTHING IN THIS COMMENT BLOCK TO FORCE A REFRESH OF THE PHONE NUMBERS TEMPLATEs-->
+
<!-- JUST MODIFY AND SAVE ANYTHING IN THIS COMMENT BLOCK TO FORCE A REFRESH OF THE PHONE NUMBERS TEMPLATE-->
  
 
= Short Term Schedule =
 
= Short Term Schedule =
 
<!--#######################################  SHORT TERM  ################################################-->
 
<!--#######################################  SHORT TERM  ################################################-->
 
<center><font color=blue size=4>
 
<center><font color=blue size=4>
''' CLAS12 Run Group B, spring 2019 </font> '''<br>
+
''' CLAS12 Run Group B, December 2019 - January 2020 </font> '''<br>
''' Beam energy 10.6 GeV (5 pass) '''<br>
+
''' Beam energy ~10.4 GeV (5 pass) '''<br>
 
''' Important: Document all your work in the logbook! '''<br>
 
''' Important: Document all your work in the logbook! '''<br>
''' Remember to fill in the [https://docs.google.com/spreadsheets/d/1NY1GNIZXPtpB9u4QwP6eNRSrvDkCzFmhQg5RR3V3j7E/edit?usp=sharing run list] at the beginning and end of each run (clas12run@gmail.com can fill the run list)'''<br>
+
<!---''' Remember to fill in the [https://docs.google.com/spreadsheets/d/17U7tyDwf1j9sdd4vd6g4ZQdKkDw3WNsdIuBRhiWy6CE/edit?usp=sharing run list] at the beginning and end of each run (clas12run@gmail.com can fill the run list)'''<br> --->
 
</center>
 
</center>
  
== RC: Yordanka Ilieva ==
+
== RC: Bryan McKinnon ==
 
* (757) 575-7540   
 
* (757) 575-7540   
 
* 9 575 7540 from Counting Room
 
* 9 575 7540 from Counting Room
* [mailto:jordanka@jlab.org jordanka@jlab.org]
+
* [mailto:mckinnon@jlab.org mckinnon@jlab.org]
  
 
== PDL: Maurizio Ungaro ==
 
== PDL: Maurizio Ungaro ==
Line 92: Line 94:
  
 
<br>
 
<br>
 +
 
  
 
{| {{TableStyle1}}  
 
{| {{TableStyle1}}  
  
 
| valign=top width=50% |
 
| valign=top width=50% |
 +
== <font color=blue>''' Run Plan: Jan 29 - 30 2020 '''</font>==
  
== <font color=blue>''' References and Standards:'''</font>==
+
* Wednesday
''(last update 2/10/2019- 12:00 PM)''
+
** Owl - Production data at 50nA
 +
** Day - Production data at 50nA
 +
** Swing - Production data at 50nA
  
<!--
+
*Thursday
<b> Preparation for Beam in Hall B </b>
+
** Owl - Production data at 50nA
 +
** 7am Request Restricted Access, Ramp Down the magnets, Empty and warm up target
 +
** 7am Contact Eugene as soon as beam off
  
* NEVER allow MCC to send tune (pulsed beam to the Faraday Cup).
 
* If MCC ask for harp scans , make sure the beam current is below 10 nA.
 
  
1) Torus and solenoid should be energized (ramping up to begin around 8:10 am of 8 Feb 2018). Torus full field (3770 A during RGA) inbending [https://clasweb.jlab.org/wiki/images/d/d6/Hall_B_Torus_Power-Up_and_Power-Down_Procedure.pdf], solenoid full field (2416 A during RGA)[https://clasweb.jlab.org/wiki/images/d/dc/Hall_B_Solenoid_Power-Up_and_Power-Down_Procedure.pdf].
+
* Please note that we have added two items to the list of tasks for each run.
 +
** (1) When you collect the gui snapshots for the logbook (scalar gui, FTC Asym plot, livetime, ROC rates, beamline stripcharts) <b>include the DAQ gui</b> AND make sure the snapshot is taken when you're running. We want to record the rate plots on the DAQ gui.  
 +
** (2) Measure the <b>trigger structure</b> (trigger-time distribution) about every 30 minutes and at least once per run enter the results in the logbook. See below for instructions. This is needed to monitor the injector laser phase which created serious problems last week.
 +
* If the trigger-time distribution or region 1 DC occupancies get worse ( > 6.5%) call the RC. What we will likely do is reduce the beam and restart.
 +
* At some later time we need to do an empty target run. Current will be 150 nA for 50M triggers which should take 2-3 hours.
 +
------
 +
'''DAQ config: <b>PROD66</b>
  
2) Target is EMPTY (target will be made ready starting at 8 am on 8 Feb 2018).
+
'''Trigger file : rgb_inbending_v9_1.trg '''
  
3) Once the magnets are ON, take a cosmic run with PROD66_PIN and trigger rgb_v0_cosmic.trg. Make sure that the following detectors must be ON: DC, HTCC, ECAL, PCAL, and FTOF. Take data as long as possible during the day shift, until MCC calls that they ready to send beam to Hall B. Call Zhiwen to start cooking the run. <br/>
 
<u>Note</u>: If MCC is ready to send beam to Hall-B before we can take this run, turn the HV of the above detectors OFF and let Hall-B go to Beam Permit status.
 
  
4) When MCC is ready to send beam for tuning in the hall
+
<b> Compare the monitoring histograms </b> <!-- from [https://clas12mon.jlab.org/mon12/histograms/?reference=3748541 clas12mon] to the reference and troubleshoot as needed.-->
* Turn the HV of all detectors OFF (including FTOF), except for MVT, which should be placed in "Safe" mode (see Note 11 below). LV should remain ON (especially important for CVT).
+
* Confirm with MCC that our BPMs have been calibrated.
 
  
<b> Restoration of Beam to Hall B</b>
+
<b> Run database: </b> <font color=red>when starting/stopping a run, enter (or check if already present) the requested current in the pop-up window and put RELEVANT COMMENTS (eg: "production run", "trigger test vXX, changed this and that" not just "run")  -- <b> please label junk runs </b> if you get the chance. Please also keep a record of run numbers and their conditions in the shift summary. </font> The information you enter in the dialogue box goes directly into the [https://clasweb.jlab.org/rcdb run database] -- it's our primary source of run info and mistakes are hard to correct a posteriori.
  
During beam tuning one should continuously monitor the leakage current on the SVT ("SVT HV Currents" graph on "SVT temps" graphic window). <b> The SVT currents should be below 10 nA.</b>
 
* When the beam is on the tagger dump, higher currents are an indication of a massive bleedthrough from other halls. To confirm, ask MCC to turn our laser off and check the currents measured by the BPMs. If bleedthrough is confirmed ask MCC to address the problem. Notify Yuri Gotra that SVT currents are high.
 
* When the beam is on the FC, higher currents are an indication of a tune beam on the FC, that goes through detector material.  <b> Tune beam on FC should never be allowed </b>. Call MCC and ask to turn the tune beam OFF. Notify Yuri Gotra that SVT currents are high.
 
  
1) Tune beam by deflecting it to the tagger dump following the procedures described in [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf].
+
Please run the script to look at <b> trigger structure </b> once per shift and check that you get a smooth distribution. Instructions are here: [https://logbooks.jlab.org/entry/3760614]
  
2) Check beam quality using harp scans 2C21 and 2C24, and compare to reference [https://logbooks.jlab.org/entry/3614928], [https://logbooks.jlab.org/entry/3614930],  [https://logbooks.jlab.org/entry/3614933]
+
Keep an eye on <b> CND channel S14L1R </b> -- it's a bit temperamental. If it trips, switch HV off and on again for it and make an entry in the log book.
  
3) Call Stepan (beamline expert cell number) to be present in the counting house. When the beam quality is acceptable, take a ''Moeller run'' to verify polarization, following procedures [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf]. Acceptable polarization is >=85%. If the polarization is not acceptable, make a separate entry in the LogBook. A spin-dance may be necessary to find the Wien angle maximizing our polarization. Such a spin dance will take place on Monday (11 Feb) morning. On 8 - 10 Feb and 11 Feb owl shifts we run with delivered polarization. In any case, record the measured polarization in the shift summary.
+
------
  
4)  Send beam to Faraday cup according to the procedure in [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf]. Reference 2C21 and 2C24 harp scans from RGA: [https://logbooks.jlab.org/entry/3614966], [https://logbooks.jlab.org/entry/3614967], [https://logbooks.jlab.org/entry/3614974]. Reference H201 harp scan from RGA: [https://logbooks.jlab.org/entry/3614975].  
+
'''<b> At the end of each run, follow the <font color=red>STANDARD DAQ RESTART SEQUENCE</font> ''' </b>'''<br>
 +
This needs to be followed at the end of every run. Note: this might be different from the instructions coming up on RunControl.
 +
<b><font color=red>
 +
* "end run", "cancel", "reset"
 +
* if the run ended correctly:
 +
**  '''"download", "prestart", "go"'''
 +
* if the run did not end correctly or if any ROCs had to be rebooted:
 +
** "configure", "download", "prestart", "go"
 +
* After each step, make sure it completed in the Run Control message window.</font></b> If a ROC has crashed, find which one it is, issue a roc_reboot command ON JUST THAT ROC and try again. Contact the DAQ expert if there are any questions.
  
5) Stepan (beamline expert cell number) is to be present in the counting house during the beam alignment with respect to the target. Check and adjust the alignment of beam with respect to the target, according to the procedure in [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf].
 
  
6) Put the beam blocker IN. Turn ON the FT Calorimeter. Ask for 15 nA beam. Check the asymmetries in X and Y on the FTCal. Acceptable values are up to 2.5%. Good tune will yield asymmetries below 1%. If the beam position needs to be adjusted, ask MCC to move the beam in small steps using 2H01 BPM. Record the final beam position values on 2C21, 2C24, and 2H01.
+
== <font color=blue>''' References and Standards:'''</font>==
 
+
''(last update 1/14/2020- 23:20)''
7) Calculate the thresholds for the Downstream and BOM components of the FSD system according to the formula in [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf]. The thresholds for the Upstream and Midstream components are 1000. Confirm with Stepan the values and finalize the thresholds.
 
 
 
8) Ask MCC to lock the orbits on the final position (typically using 2C24 and 2H01) and to set the FSD limits to the values from 7). Ask for 5 nA beam.
 
 
 
9) Call Youri Gotra to come to the counting house for the first turing ON of MVT and SVT (the procedure of turning ON SVT is in https://logbooks.jlab.org/entry/3615766). Turn all other detectors ON.
 
 
 
10) RC fills up the target with LD2 (the procedure is written in the papers which is on the left of the keyboard of the target computer, which is facing the window looking over the electronics room).
 
 
 
11) If beam energy is too different (by ~ one hundred or more MeV), contact Rafo for re-calibration of the FC reading.
 
-->
 
  
 
<b> Nominal Beam Positions </b>
 
<b> Nominal Beam Positions </b>
*2H01, X: +3.0 mm, Y: -1.0 mm
+
*2H01, X: +1.0 mm, Y: -2.6 mm
*2C24, X: +0.16 mm, Y: 0.26 mm
+
*2C21, X:  0.0 mm, Y:  0.2 mm
 +
*2C24, X: -0.3 mm, Y: -0.8 mm
  
 
<b> FSD Thresholds </b>
 
<b> FSD Thresholds </b>
 
* Upstream: 2000 Hz
 
* Upstream: 2000 Hz
 
* Midstream: 2000 Hz
 
* Midstream: 2000 Hz
* Downstream: 500000 Hz
+
* Downstream: 700000 Hz
* BOM: 35000
+
* BOM: 60000
 +
 
 +
<b> Reference Harp Scans for Beam on Faraday Cup: </b> 2C21 [https://logbooks.jlab.org/entry/3759969], 2C24 (tagger harp) [https://logbooks.jlab.org/entry/3759229], 2H01 [https://logbooks.jlab.org/entry/3759255]
  
<b> Reference Harp Scans for Beam on Tagger Dump: </b> 2C21 [https://logbooks.jlab.org/entry/3649356], 2C24 [https://logbooks.jlab.org/entry/3649362]
+
<b> Reference Harp Scans for Beam on Tagger dump: </b> 2C21 [https://logbooks.jlab.org/entry/3759158], 2C24 (tagger harp) [https://logbooks.jlab.org/entry/3759160]
  
<b> Reference Harp Scans for Beam on Faraday Cup: </b> 2C21 [https://logbooks.jlab.org/entry/3649467], 2C24 [https://logbooks.jlab.org/entry/3649472], 2H01 [https://logbooks.jlab.org/entry/3649461]
+
<b> Reference Monitoring Histograms (40 nA, production trigger) </b> [https://logbooks.jlab.org/entry/3748541]
  
<b> Reference Monitoring Histograms (20 nA, production trigger) </b> [https://logbooks.jlab.org/entry/3650218]
+
<b> Counter rates </b>
 +
* Upstream counters integrated rates: 0-15 Hz (acceptable up to 100 Hz are acceptable) @50 nA.
 +
* Midstream counters: 10-20 Hz (acceptable up to 50 Hz) @50 nA.  
 +
* Counting rates of ~ hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.
  
<b> Reference Monitoring Histograms (35 nA, production trigger) </b> [https://logbooks.jlab.org/entry/3650729]
+
<b> Beamline vacuum: </b> should be not higher than 5e-5.
  
 +
<!---
 
<b> Reference Scalers and Halo-Counter Rates: </b>  
 
<b> Reference Scalers and Halo-Counter Rates: </b>  
* Well-tuned CW beam on FC, Full LD2 target, CLAS12 ON: 5 nA [https://logbooks.jlab.org/entry/3649861], 10 nA [https://logbooks.jlab.org/entry/3649888], 20 nA [https://logbooks.jlab.org/entry/3649905], 30 nA [https://logbooks.jlab.org/entry/3649916], 40 nA [https://logbooks.jlab.org/entry/3649938], 50 nA [https://logbooks.jlab.org/entry/3649959], 60 nA [https://logbooks.jlab.org/entry/3649970], 75 nA [https://logbooks.jlab.org/entry/3649985]
+
* Well-tuned CW beam on FC, Full LD2 target, CLAS12 ON (Feb 2019): 5 nA [https://logbooks.jlab.org/entry/3649861], 10 nA [https://logbooks.jlab.org/entry/3649888], 20 nA [https://logbooks.jlab.org/entry/3649905], 30 nA [https://logbooks.jlab.org/entry/3649916], 40 nA [https://logbooks.jlab.org/entry/3649938], 50 nA [https://logbooks.jlab.org/entry/3649959], 60 nA [https://logbooks.jlab.org/entry/3649970], 75 nA [https://logbooks.jlab.org/entry/3649985]
* Well-tuned CW beam on FC, Empty Target, CLAS12 OFF: 5 nA [https://logbooks.jlab.org/entry/3649436]
+
* Well-tuned CW beam on FC, Empty Target, CLAS12 OFF (Feb 2019): 5 nA [https://logbooks.jlab.org/entry/3649436]
* Well-tuned beam during Moller run [https://logbooks.jlab.org/entry/3649364]
+
* Well-tuned beam during Moller run (Feb 2019) [https://logbooks.jlab.org/entry/3649364]
* Well-tuned beam on Tagger Dump at 5 nA during harp scans: [https://logbooks.jlab.org/entry/3649358]  
+
* Well-tuned beam on Tagger Dump at 5 nA during harp scans (Feb 2019): [https://logbooks.jlab.org/entry/3649358]
 +
* Reference FTC histogram for 5 nA running (Feb 2019): [https://logbooks.jlab.org/entry/3665122]
  
<b> SVT acceptable currents: </b> <10 nA (typically < 1 nA) with no beam and no HV; ~< 400 nA (HV ON, no beam); 10 nA [https://logbooks.jlab.org/entry/3649889], 20 nA [https://logbooks.jlab.org/entry/3649911], 30 nA [https://logbooks.jlab.org/entry/3649920], 40 nA [https://logbooks.jlab.org/entry/3649941], 50 nA [https://logbooks.jlab.org/entry/3649960], 60 nA [https://logbooks.jlab.org/entry/3649972], 75 nA [https://logbooks.jlab.org/entry/3649986]
+
<b> SVT acceptable currents (Feb 2019): </b> <10 nA (typically < 1 nA) with no beam and no HV; ~< 400 nA (HV ON, no beam); 10 nA [https://logbooks.jlab.org/entry/3649889], 20 nA [https://logbooks.jlab.org/entry/3649911], 30 nA [https://logbooks.jlab.org/entry/3649920], 40 nA [https://logbooks.jlab.org/entry/3649941], 50 nA [https://logbooks.jlab.org/entry/3649960], 60 nA [https://logbooks.jlab.org/entry/3649972], 75 nA [https://logbooks.jlab.org/entry/3649986]
 +
--->
  
== <font color=blue>''' Run Plan:'''</font>==
+
| valign=top |
Production-run DAQ configuration '''PROD66''', trigger file '''rgb_v0.trg'''.
 
  
<!--
+
==<font color=blue>''' General Instructions''':</font>==
<b> Data taking on 10 Feb </b>  
 
Production-run DAQ configuration '''PROD66''', trigger file '''rgb_v0.trg'''.
 
  
 +
* The <b> main lights in the Hall </b> (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during an access, they should be switched off when leaving the Hall. Note that the dome lights when switched off cannot be turned back on immediately because they require 10-15 min to cooldown.
 +
* Do not run more than 30 minutes above 30 nA with 5-pass beam without the <b> beam blocker in front of Faraday cup </b>. Put beam blocker in for long running at high currents for 5 pass operations.
 +
* Turn <b> DC HV </b> off only for beam tuning; if no beam is available or when beam is stable, keep them on even if you are not taking data.
 +
* In case of loss of communication with <b> IOCBTARG </b>, follow instructions at https://logbooks.jlab.org/entry/3502218
 +
* With any issue contact On-Call Experts or RC - <b> do not spend more than 15-20 min trying to fix the problem</b>. If the phone is not answered, try the "Page Experts" button on top of CLASCSS.
 +
* Check for and read any comments to log-book entries made during your shift!
  
1) Call FTOF/CTOF expert on call, Florian Hauenstein, and Yuri Gotra to be present in the counting house during the luminosity scans. Do a current scan (5, 10, 20, 40, 50, 60, 65, 75 nA) checking and writing down trigger rates, data rates, DC occupancies, FTOF and CTOF scalers, and CVT current. Be aware that with a deuterium target we may get higher rates than for RGA, at a given current. The current values above are tentative. The maximum current, beyond which we cannot go is determined by the DC occupancies (3% - 4%). However, if DC occupancies permit it, we should go up to 75 nA in the scan even if trigger and data rates are above the nominal limits. This is a quick scan where all data are in a single run. (~5 min per beam current).
 
*If the detector can handle higher current, but the data rate is higher than ~450 MB/s, or average rate is higher than 350 MB/s, make a separate log entry. We will have to negotiate with scicomp an increase of our allowed data rate.
 
*Pick the beam current for standard production running that allows acceptable rates (DC occupancies ~3-4%, trigger rates~10k, data rates~450 MB/s).
 
  
1) Trigger validation studies (random trigger), 200 M events at 40 nA; stable beam. Valery and Rafo should be called in advance (see white board in the counting house for cell numbers). DAQ configuration: PROD66_PIN. Trigger file: Diagnostics/RGB_trg_v30_validate_Basicelectron.trg. Determine the average current after 3 hours of running (myStats -b -180m -l IPM2C21A) and if it is less than 40 nA, prorate the 200 M events to a larger value. When you start the run, call Zhiwen to begin cooking the run.
+
'''Every Shift:'''
 +
* Follow run plan as outlined by RC
 +
* If any concern about beam stability, ask MCC if orbit locks are on (they should be).
 +
* Keep shift summary up to date in HBLOG. Record all that happens.
 +
* Document any beam condition change and send scaler GUIs to HBLOG
 +
* [https://bta.acc.jlab.org Fill out BTA] hourly.  Click "Load from EPICS" to automatically fill the left side. Run the script <font color=red>btaGet.py</font> to print for you the correct BTA info for this hour -- edit the values on the BTA page if they are wrong!
 +
* Upload spectra from clas12mon at begin and end of shift and cross-check with reference spectra (make sure you select the SAME SECTOR as for the reference plots on tabs which have multiple sectors).
 +
** Reset clas12mon every ~2 hours and inspect spectra (some detectors have buttons at the bottom to toggle between the sectors -- please check all of them).
 +
* Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook]
 +
* Run script to check smoothness of the trigger time structure: [https://logbooks.jlab.org/entry/3749715]
 +
* Monitor the SVT Slow Controls status, post plot of current stability in the HBSVT elog once per shift.
  
2) Take a production run at 20 nA (4 hours) with '''PROD66_PIN''' and '''rgb_v0.trg''' to be used for HTCC and FTOF/CTOF thresholds and HV final adjustments, as well as trigger validation. When you start the run, contact Zhiwen (phone number on white board in the counting house) to start cooking the run.
 
  
---------
+
'''Every Run:'''
1) Take tracking efficiency run with '''PROD66_PIN''' and '''rgb_v0.trg''' at 5 nA for about 4 hours.
+
*Check values at the start of every run and log screenshots of:
 +
** Main scaler GUI display
 +
** Trigger rate GUI
 +
** Beam strip charts
 +
** FTC scalers
 +
* At the start and end of every run, check that the data filled in the [https://clasweb.jlab.org/rcdb database run list] is correct (especially fields which are filled in manually, like beam current and comments). This replaces the previously-used spreadsheet.
 +
* <b> When checking the ECAL response, make sure to look at the histograms for each sector by using the sector buttons at the bottom of the clas12mon window - if adcecal* or/and adcpcal* ROC crashes, there will be no alarm and the histograms are the way to notice this issue.
 +
* Same holds for FTOF.</b>
  
2) Take tracking efficiency run with '''PROD66_PIN''' and '''rgb_v0.trg''' at 35 nA for about 2 hours.
 
  
3) Take tracking efficiency run with '''PROD66''' and '''rgb_v0.trg''' at 10 nA until Monday morning or until further notice by RC. One run is about 2-hours long.
+
'''To access the Hall:'''
 +
* If you need to go down into Hall B alert Denny Insley (757-897-9060, cell/text: 757-810-9576) and the Run Coordinator (757-575-7540).
 +
* Check in with the shift personnel before entering the hall.
  
-->
+
|}
  
<!--
 
3) Trigger validation studies (random trigger), ... M events at 10 nA; stable beam. Valery and Rafo should advise on the number of events to collect. DAQ configura3) Trigger validation studies (random trigger), ... M events at 10 nA; stable beam. Valery and Rafo should advise on the number of events to collect. DAQ configuration: PROD66_PIN. Trigger file: Diagnostics/RGB_trg_v30_validate_Basicelectron.trg. Determine the average current after ... hours of running (myStats -b -180m -l IPM2C21A) and if it is less than 10 nA, prorate the ... M events to a larger value. When you start the run, call Zhiwen to begin cooking the run.
 
If beam is stable and we had completed the beam-current measurements to high currents, take a tracking efficiency run with '''PROD66_PIN''' and '''rgb_v0.trg''' at 50 nA for about 2 hours. (Confirm with RC that you can request such a high current).
 
-->
 
  
<!--
+
==<font color=blue>''' Notes / Troubleshooting ''':</font>==
<b> Plan for 11 Feb </b>
 
  
<!--
+
<b>If crate ADCBAND was rebooted:</b> Contact BAND expert and make a note in the HBBAND logbook and in HBLOG.
1) Keep running at 10 nA until MCC calls and informs that they are ready for Spin Dance.
 
2) Complete all logbook screenshots of scalers, etc. and submit monitoring histos to logbook if not done earlier.
 
-->
 
*Beam is OFF for RF studies. CLAS12 has HV OFF (LV remain ON), except for MVT, which is placed in a "Safe Mode" as per instructions above and on the white board.
 
* Hall B is in controlled access.
 
*Wait for MCC to call that they will begin Spin Dance
 
*Preparation for and taking Moller runs [https://wiki.jlab.org/clas12-run/images/e/e4/Clas12moller.pdf]
 
**Blank collimator is IN
 
**MCC will energize the tagger magnet
 
**Take a Moller run at the current value of the Wien angle. Polarization uncertainty must be <=1.5%.
 
**MCC will change the Wien angle by 25deg. When they call that this is complete, take a Moller run at that angle. Polarization uncertainty must be <=1.5%.
 
**MCC will change the Wien angle by -25deg. When they call that this is complete, take a Moller run at that angle. Polarization uncertainty must be <=1.5%.
 
**Using the three sets of values (polarization, Wien angle), MCC will estimate at which angle, theta_W_max, the polarization is maximal and will set that angle.
 
**Take a Moller run at the new angle and the current position of the half-wave plate (HWP), IN. Polarization uncertainty must be <=1.5%.
 
**Ask MCC to change the position of the HWP to OUT. Take a Moller run. Polarization uncertainty must be <=1.5%.
 
**End of Spin Dance. Record the new value of the Wien angle.
 
* Ask MCC to take the beam away, turn off the tagger magnet, and degauss it. Ask MCC to unmask our FSDs.
 
* Retract the blank collimator and put the 20-mm collimator on the beam line.
 
* With beam off, turn all detectors' HV ON, except for MVT, which needs to be brought to "HV_FullField".
 
* Ask for 5 nA beam. Check that the beam positions, the rates of the beam halo scalers, FSD scalers, detector scalers, and the FTCal asymmetries are consistent with the reference values at the same current (see References and Standards above). If beam positions are off, ask MCC to engage the orbit locks. If orbits locks are engaged, but the beam positions are not up to specs, call the RC.
 
* If beam looks good, ask MCC for 35-nA beam and start taking production data. Each run is 2-hours long.
 
** Take the first run with PROD66_PIN and $CLON_PARMS/trigger/rgb_v1.trg.
 
** Take the rest of the runs with PROD66 and $CLON_PARMS/trigger/rgb_v1.trg.
 
-->
 
  
<b> Plan for 12 Feb </b>
+
<b> FTOF HVs: </b> The goal is to minimize the number of power cycles of the dividers.
 +
** OFF during: initial beam tuning to the Faraday Cup after CLAS12 has been off for a long shutdown, during a Moller run, harp scans, or if there is tuned/pulsed beam in the upstream beamline.
 +
** ON after an initial beam tune has been established and if there are only minor steering adjustments and “tweaks” being made.
 +
** <i>If in doubt, call FTOF expert </i>
  
Spin Dance is complete. Wien angle: 34 deg; measured polarization HWP IN: 85.4+-1.5; measured polarization HWP OUT: 83.6+-1.5. HWP is now OUT.
+
<b>FTT (mmft1) recovery</b>:  
  
We run with trigger file rgb_v1.rg, which provides the same trigger as v0, but has some built-in checks of the muon trigger.
+
** power cycle FTT LV (FT->FTT->turn LV OFF, turn LV ON)
 +
** RunControl "reset"
 +
** roc_reboot mmft1
  
* Run 6189 ongoing with PROD66_PIN and rgb_v1.trg. Take data for 2 hours. 35 nA.
+
<b>Torus and/or Solenoid Fast Dump </b>
* For the rest of the day, take 2-hrs long runs with <b> PROD66 </b> and <b> rgb_v1.trg </b>.
+
*# Notify MCC to request beam OFF and to drop Hall B status to Power Permit
* Complete all tasks as speficied on this page "Once per Run" and "Once per Shift".
+
*# Call Engineering on-call
 +
*# Make separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Ruben Fair, Probir Goshal, Dave Kashy and esr-users@jlab.org
 +
*# Notify Run Coordinator
 +
*# Turn off all detectors
  
  
| valign=top |
+
<b> Beam to the Faraday Cup: Fast Shut Down elements </b>
 +
* Upstream, Midstream, Downstream, BOM, and Solenoid FSD elements should always be in the state <font color=red>UNMASKED</font>
 +
* No changes to the FSD threshold should be made without RC or beamline expert approval
  
==<font color=blue>''' General Instructions''':</font>==
 
  
* For a given beam current, compute the FSD thresholds according to the [https://wiki.jlab.org/clas12-run/images/e/e3/Estab_beam.pdf Establish Physics Quality Beam] document. Call MCC to update the values. Contact the beamline expert if there are questions about setting the FSD thresholds.
+
<b> Turning MVT off: </b> do not press "All HV OFF". Instead go to 'Restore settings' from the MVT overview screen:
* The main lights in the Hall (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during an access, they should be switched off when leaving the Hall. Note that the dome lights when switched off cannot be turned back on immediately because they require 10-15 min to cooldown.
+
*# SafeMode.snp for beam tuning and Moeller runs
* Do not run more than 60 minutes above 30 nA with 5-pass beam without the beam blocker in front of Faraday cup. Put beam blocker in for long running at high currents for 5 pass operations.
+
*# MV_HV_FullField.snp for full solenoid field
* Turn DC HV off only for beam tuning; if no beam is available or when beam is stable, keep them on even if you are not taking data.
+
*# MV_HV_MidField.snp wgeb solenoid < 4T
* In case of loss of communication with IOCBTARG, follow instructions at https://logbooks.jlab.org/entry/3502218
 
* With any issue contact On-Call Experts or RC - do not spend more than 15-20 min trying to fix the problem.
 
* All jscaler iocs (iocjscalerX) on the health screen (under DAQ tab) must be restarted after every DAQ prestart is completed.
 
* Check that no unecessary beamline-related screens are open.  This includes particularly the big beamline overview screen, but also and any motor/harp/collimator screens, and ioc health screens.
 
* Check for and read any comments to log-book entries made during your shift.
 
 
 
'''Every Shift:'''
 
*Follow run plan as outlined by RC
 
* If any concern about beam stability, ask MCC if orbit locks are on (they should be).
 
* Keep shift summary up to date in HBLOG. Record all that happens.
 
* Check on white board all scalers, strip charts and monitoring plots that need to be logged regularly
 
* Document any beam condition change and send scaler GUIs to HBLOG
 
* [https://bta.acc.jlab.org Fill out BTA] hourly.  Click "Load from EPICS" to automatically fill the left side.
 
# Fill and submit the [https://logbooks.jlab.org/checklists/151 shift checklist in the logbook]
 
# Perform 2H01A harp scan once per shift or when beam conditions have changed, based on beam monitors (BPMs, halo rates, beam-viewer). During harp scans the HV for DC and HTCC should be OFF.
 
* Monitor the SVT Slow Controls status, post plot of current stability in the HBSVT elog once per shift.
 
* As of 9th of February, once per shift stop and start the gas flow of the FTT (see logbook entry [https://logbooks.jlab.org/entry/3649533] for more details. Check the FTT HV after the procedure. If it is Off, check the status of all gas interlocks, reset the one that is at "Fault" and turn the FTT HV back ON.
 
'''Every Run:'''
 
 
 
*Log screenshots of:
 
** main scaler GUI display (both at the begining and at the end of run)
 
** Detector occupancy plots from clas12mon
 
** Trigger rate gui
 
** Beam strip charts
 
* Fill out the run info in [https://docs.google.com/spreadsheets/d/1NY1GNIZXPtpB9u4QwP6eNRSrvDkCzFmhQg5RR3V3j7E/edit#gid=0 run list] at the beginning and at the end of each run.
 
* Compare the monitoring histograms from clas12mon to the reference and troubleshoot as needed. <b> When checking the ECAL response, make sure to look at the histograms for each sector by using the sector buttons at the bottom of the clas12mon window - if adcecal* or/and adcpcal* ROC crashes, there will be no alarm and the histograms are the way to notice this issue. </b>
 
  
|}
 
  
 +
<b> CND CAMAC crate switch on / reboot: </b>
  
* '''Note 1: Be very mindful of the background rates in the halo counters, rates in the detectors, and currents in the SVT for all settings to ensure that they are at safe levels.'''
+
If CAMAC crate (camac1) holding CND CFD boards is switched off for any reason, always reset the associated CND CFD thresholds by typing, ssh into clondaq3 and type:
The integrated rates on the upstream counters have to be in the range 0-15 Hz (rates up 100 Hz are acceptable) and the rates on the midstream counters have to be in the range 10-20 Hz (acceptable up to 50 Hz) @50 nA. Counting rates in the range of hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.
 
  
* ''' Note 2: At the end of each run, follow the standard DAQ restart sequence '''
+
$CODA/src/rol/Linux_x86_64/bin/cnd-cfd-thresh -w 0
"end run", "cancel", "reset", then if the run ended correctly, '''"download", "prestart", "go"'''. If the run did not end correctly or if any ROCs had to be rebooted, "configure", "download", "prestart", "go".
 
  
After each step, make sure it is complete in the Run Control message window. If a ROC has crashed, find which one it is and issue a roc_reboot command and try again. Contact the DAQ expert if there are any questions.
+
If this command is failing and the crate is not responding, first reboot it as follows: roc_reboot camac1
  
* '''Note 3: Nominal beam positions: <font color=red>''' ''' 2C24A (X= 0.16 mm, Y= 0.26 mm) ''', '''2H01 (X=3.00 mm, Y= -1.00 mm)''' </font>
+
and then repeat the threshold reset command above.
  
* '''Note 4: FTOF HVs: The goal is to minimize the number of power cycles of the dividers.
 
** should be turned off during the initial beam tuning down to the Faraday Cup after CLAS12 has been off for a long shutdown, when doing a Moller run, when doing harp scans, or if there is tuned/pulsed beam in the upstream beamline.'''
 
** should be left on after an initial beam tune has been established and if there are only minor steering adjustments and “tweaks” being made.
 
** if shift workers have doubts what to do with the HVs, they can always contact the TOF on-call expert for advice.
 
  
* '''Note 5: In case of a Torus and/or Solenoid Fast Dump do the following:
+
<b> Solutions for common SVT issues: </b> see [https://logbooks.jlab.org/entry/3615766]
*# Notify MCC to request beam OFF and to drop Hall B status to Power Permit
 
*# Call Engineering on-call
 
*# Make separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Ruben Fair, Probir Goshal, Dave Kashy and esr-users@jlab.org  
 
*# Notify Run Coordinator
 
*# Turn off all detectors'''
 
  
*'''Note 6: When beam is being delivered to the Faraday Cup:'''
 
*# the Fast Shut Down elements: Upstream, Midstream, Downstream, BOM, and Solenoid should always be in the state <font color=red>UNMASKED</font>
 
*# No changes to the FSD threshold should be made without RC or beamline expert approval
 
<!--*'''Note 7: Do not turn on the SVT or MM - only the SVT or MM expert can do that''' -->
 
  
*'''Note 7: Any request for a special run or change of configuration has to be approved by the RC & documented'''
+
<b> RICH recovery procedures: </b> [https://logbooks.jlab.org/entry/3562273]
  
*'''Note 8: Carefully check the BTA every hour and run the script <font color=red>btaGet.py</font> to print for you what HAS TO BE in BTA for this hour. Edit BTA if it is incorrect.'''
+
To be followed in case of:
 +
# DAQ crash: rich4 is not responding or
 +
# RICH alarms (LV,missing tile, temperature, etc).
 +
<i> If it does not work or you are uncertain about what to do, contact the RICH expert on call. </i>
 +
<u>Please note </u> that missing tiles typically occur due to lost communication. Keep in mind that the recovery procedure will kill DAQ. If DAQ is running for purpose other than data taking (for which the RICH acceptance is important) do not initiate the recovery procedure.  
 +
The most critical parameter for the RICH is the temperature of the photosensors. If the temperature rises above limits, an interlock will automatically turn the RICH HV and LV off. If this happens, notify the expert on call and keep taking data without RICH.
  
*'''Note 9: Reset CLAS12MON frequently to avoid histogram saturation.'''
 
 
*'''Note 10: Shift workers must check the occupancies! Use this tool to compare to previous runs: [https://clas12mon.jlab.org/mon12/histograms/?reference=3650729]'''
 
<!--[https://clas12mon.jlab.org/mon12/histograms/?reference=3621580]'''-->
 
 
*'''Note 11 Do not Turn OFF MVT HV: Instead go to 'Restore settings' from the MVT overview screen:
 
*# SafeMode.snp for beam tuning and Moeller runs
 
*# MV_HV_FullField.snp for full solenoid field
 
*# MV_HV_MidField.snp wgeb solenoid < 4T
 
'''
 
*'''NOTE 12 Check the vacuum periodically, make sure vacuum id not higher than 5e-5 '''
 
  
*''' NOTE 13 Always reset the CFD threshold after all power off/on on the CND CAMAC crate'''
+
<b> Observed asymmetry in FTCal ADC Scalers </b>
After the CAMAC crate (camac1) holding the CND CFD boards is switched off for any reason, it is mandatory to reset the associated thresholds typing the
 
following command from any clon machine terminal: $CODA/src/rol/Linux_x86_64/bin/cnd_cfd_thresh -w 0
 
  
If this command is failing and the crate is not responding, reboot it as follows: roc_reboot camac1
+
When running at low current (<10 nA), FTC asymmetries can be affected by hot channels. If large asymmetries are detected in those conditions, cross check with other  detectors (BOM rates, DC occupancies) before taking further action.
  
*'''NOTE 14 ''' Shift workers should anyway check routinely scalers to verify they update correctly and make a logbook entry if anomalies are observed after starting a new run.
 
  
*'''NOTE 15: To solve common SVT issues see https://logbooks.jlab.org/entry/3615766'''
+
<b> CED display not showing events </b>
  
*'''NOTE 16: After any reboot of crate 'adcband1', reboot tdcband1 crate''' to avoid sync problems of TDCs.'''
+
Sometimes, CED screens are up but not active (events not showing at all). To solve this:
  
*'''NOTE 17:''' For RICH recovery procedures, please see Log entry https://logbooks.jlab.org/entry/3562273.  This would apply in the cases of  1. DAQ crash: rich4 is not responding or 2. RICH alarms (LV,missing tile, temperature etc). If it does not work or you are uncertain about what to do, contact the RICH expert on call. <u>Please, note </u> that missing tiles typically occur due to lost communication. Keep in mind that the recovery procedure will kill DAQ. If DAQ is running for other purpose, rather than data taking (for which the RICH acceptance would be important) do not initiate the recovery procedure.  
+
# Close the CED sceen
** The most critical parameter for RICH is the temperature of the photosensors. If the temperature rises above limits, an interlock will automatically turn the RICH HV and LV. If this happens, notify the expert on call and keep taking data without RICH.
+
# ssh to clondaq4
 +
# Once in the right machine, type ced, and wait for the windows to appear.
 +
# Go to "File" -> "Connect to ET ring". Make sure to select clondaq6, as the online data is being streamed.
 +
# Go to "Events" (same level as "File") and check "Auto Next-Event Every 2.0 sec" (if it is not selected).
  
*'''NOTE 18:''' Asymmetry on FTCal ADC Scalers: If the beam current is 5 - 10 nA, and the observed asymmetry is out of specs, i.e. > +-2.5%, check (1) that the beam position is according to specs, (2) the response of the rest of CLAS (compare the scalers of FTOF, CTOF, ECAL, etc. from the Scalers GUI to the reference for that current, as posted above). If positions and other detectors do not show any anomalies, keep running. The ADC scalers require at least ~15 nA for a reliable response.
+
You should see the events now, if all is working well.
  
 
= Monitoring =
 
= Monitoring =
Line 360: Line 322:
 
===Epics on the web===
 
===Epics on the web===
 
*[https://hallbopi.jlab.org/webopi3.3/w WebOPI] (CUE Login)
 
*[https://hallbopi.jlab.org/webopi3.3/w WebOPI] (CUE Login)
 +
 +
| valign=top |
 +
===Runs and Coooking Info===
 +
*[https://docs.google.com/spreadsheets/d/1NY1GNIZXPtpB9u4QwP6eNRSrvDkCzFmhQg5RR3V3j7E/edit?usp=sharing Google Spreadsheet Run list]
 +
*[https://clas12mon.jlab.org/fstree Run list of decoded and cooked files (auto updating every 30m)]
 +
*[https://jeffersonlab-my.sharepoint.com/:x:/g/personal/zwzhao_jlab_org/Ef0DF0RF5UpCvKrwZf5u4cAB3IYkCp8-vaXCk8NmjewvKw?e=cSQB3m Run list with decoding and cooking software version/condition]
 +
 +
|}
 +
== December 2019 - January 2020 Run ==
 +
{| {{TableStyle1}}
 +
| valign=top |
 +
[[Image:rgb_winter_charge.jpg|fall2018_charge.jpeg|700px]]
 +
 +
| valign=top |
 +
[[Image:Rgb_spring_moller.jpg|500px]]
 +
|}
 +
 +
== Winter 2019 Run ==
 +
{| {{TableStyle1}}
 +
| valign=top |
 +
[[Image:rgb_winter_charge.jpg|fall2018_charge.jpeg|700px]]
 +
 +
| valign=top |
 +
[[Image:Rgb_spring_moller.jpg|500px]]
 +
|}
 +
 +
{| {{TableStyle1}}
 +
=== mini-Spin dance ===
 +
| valign=top |
 +
[[Image:rgb_sd_final.jpg|500px]]
 +
 +
| valign=top |
 +
[[Image:rgb_sprn_dance_10p2.jpg|500px]]
  
 +
|}
 +
{| {{TableStyle1}}
 +
=== mini-Spin dance ===
 +
| valign=top |
 +
[[Image:rgb_sprn_dance_10p2.jpg|500px]]
 +
 +
| valign=top |
 +
[[Image:Rgb_spring_moller_10p2.jpg|500px]]
 
|}
 
|}
  
Line 372: Line 375:
 
* [https:////clasweb.jlab.org/wiki/index.php/Run_Group_B Run Group B Wiki]
 
* [https:////clasweb.jlab.org/wiki/index.php/Run_Group_B Run Group B Wiki]
 
* [https://clas12mon.jlab.org/ CLAS12 mon page]
 
* [https://clas12mon.jlab.org/ CLAS12 mon page]
* [https://clas12mon.jlab.org/mon12/histograms/?reference=3630375 Comparison of current mon12 histos (second column) to a reference set of histograms (first column) and mon12 histograms (last 5 runs in last columns)]  
+
<!-- * [https://clas12mon.jlab.org/mon12/histograms/?reference=3767514 Comparison of current mon12 histos (second column) to a reference set of histograms (first column) and mon12 histograms (last 5 runs in last columns)]  -->
 +
* [https://clas12mon.jlab.org/mon12/histograms/?reference=3768773 Comparison of current mon12 histos (second column) to a reference set of histograms (first column) and mon12 histograms (last 5 runs in last columns)]  
 
* [https://clas12mon.jlab.org/datasize/ Accumulated datasize]
 
* [https://clas12mon.jlab.org/datasize/ Accumulated datasize]
 
* [https://clas12mon.jlab.org/charge/ Accumulated charge]
 
* [https://clas12mon.jlab.org/charge/ Accumulated charge]
 +
 +
===Run lists===
 +
* [https://docs.google.com/spreadsheets/d/1NY1GNIZXPtpB9u4QwP6eNRSrvDkCzFmhQg5RR3V3j7E/edit?usp=sharing  RGB Winter  19 run list]
 +
* [https://docs.google.com/spreadsheets/d/17U7tyDwf1j9sdd4vd6g4ZQdKkDw3WNsdIuBRhiWy6CE/edit?usp=sharing  RGB Fall 19 run list]
  
 
| valign=top |
 
| valign=top |
 
===Accelerator===
 
===Accelerator===
 
* [http://accboard.acc.jlab.org Accelerator Whiteboard]
 
* [http://accboard.acc.jlab.org Accelerator Whiteboard]
* [http://opweb.acc.jlab.org/CSUEApps/bta03/pd_shiftplan_history.php Program Deputy Shift Plans]
+
* [https://accweb.acc.jlab.org/apps/pd/shift-plans Program Deputy Shift Plans]
 
* [http://opweb.acc.jlab.org/internal/ops/ops_webpage/run_coord/runcoord_form.php?action=main Run Coordinator Reports]
 
* [http://opweb.acc.jlab.org/internal/ops/ops_webpage/run_coord/runcoord_form.php?action=main Run Coordinator Reports]
 
* Accelerator daily meetings notes (by Mauri) [https://www.evernote.com/pub/maureeungaro/pdldaily]
 
* Accelerator daily meetings notes (by Mauri) [https://www.evernote.com/pub/maureeungaro/pdldaily]
 
| valign=top |
 
| valign=top |
 
===Bluejeans meetings===
 
===Bluejeans meetings===
* [https://bluejeans.com/230805731 Daily Run meeting] 230805731
+
* [https://bluejeans.com/8928008153 Daily Run meeting] 8928008153
* [https://bluejeans.com/2488723183 RGB meeting] 2488723183
+
* [https://bluejeans.com/237353330 Weekly RGB meeting] 237353330
  
 
|}
 
|}

Latest revision as of 13:42, 25 July 2024

[edit]

Shift Schedule

Shift Checklist

Hot Checkout

Beam Time Accounting

ESAD, COO, RSAD, ERG

Manuals

Procedures

JLab Logbooks

RC schedule

  • Nov 20 - Nov 27: S. Stepanyan
  • Nov 27 - Dec 4: M. Contalbrigo
  • Dec 4 - Dec 11: D. Sokhan
  • Dec 11 - Dec 18: S. Niccolai
  • Dec 18 - Dec 20 S. Stepanyan
  • Jan 7 - Jan 15: J. Gilfoyle
  • Jan 15 - Jan 22: F. Hauenstein /W. Phelps
  • Jan 22 - Jan 30: B. McKinnon

Role Phone Number
Hall B Run Coordinator (757) 575-7540 (cell)
Hall B Physics Division Liaison (757) 876-1789 (cell)
MCC 7048
Crew Chief 7045
Crew Chief (757) 876-3367 (cell)
Program Deputy (757) 876-7997 (cell)
RadCon (757) 876-1743 (cell)
Gate House Guard 5822
Location Phone Number
Hall B Floor 5165
Hall B Space Frame 5170 and 5171
Hall B Forward Carriage 5371
Hall B Gas Shed 7115
Hall B Counting House 5244 (Shift Expert)
Hall B Counting House (757) 329-4846 (Shift Expert cell)
Hall B Counting House 5245 or 5126 (Shift Worker)
Hall A Counting House 5501
Hall C Counting House 6000
Hall D Counting House 5504
Hall B System Phone Number On-Call Person
Engineering (757) 748-5048 (cell)
(757) 897-9060 (cell)
Engineering On-Call (primary)
Denny Insley (secondary)
Slow Controls (757) 748-6922 (cell) Nathan Baltzell
Beamline (757) 303-3996 (cell) Eugene Pasyuk
DC (757) 218-4372 (cell)
(757) 748-5048 (cell)
Florian Hauenstein (primary)
Engineering On-Call (secondary)
SVT/MVT/MM (757) 541-7539 (cell)
(757) 753-7769 (cell)
Yuri Gotra (primary)
Rafo Paremuzyan (secondary)
ECAL (757) 810-1489 (cell) Cole Smith
FTOF/CTOF/CND (757) 344-7204 (cell) Daniel Carman
ALERT (757) 329-4844 (cell) Raphael Dupré
HTCC/LTCC (757) 344-7174 (cell) Youri Sharabian
FT (757) 344-1848 (cell) Raffaella De Vita
BAND (757) 310-7198 (cell) Florian Hauenstein
RICH (757) 344-3235 (cell)
(757) 748-6922 (cell)
Christopher Dilks (primary)
Nathan Baltzell (secondary)
DAQ (757) 232-6221 (cell) Sergey Boiarinov
HYDRA (317) 550-9226 (cell) Torri Jeske
Authorized Hall B Solenoid/Torus Operators
Hall B Denny Insley, Morgan Cook, Eugene Pasyuk
Magnet Group Probir Ghosha, Renuka Rajput-Ghoshal
Detector Support Group Brian Eng, Pablo Campero, Tyler Lemon
DC Power Onish Kumar, Sarin Philip
  • Note, all non-JLab numbers must be dialed with an area code. When calling from a counting-house landline, dial "9" first.
  • To call JLab phones from outside the lab, all 4-digit numbers must be preceded by 757-269
  • Click Here to edit Phone Numbers. Note, you then also have to edit the current page to force a refresh.

Click Here to edit Phone Numbers. Note, you then also have to edit this page to force a refresh.


CLAS12 Run Group B, December 2019 - January 2020
Beam energy ~10.4 GeV (5 pass)
Important: Document all your work in the logbook!

RC: Bryan McKinnon

PDL: Maurizio Ungaro



Run Plan: Jan 29 - 30 2020

  • Wednesday
    • Owl - Production data at 50nA
    • Day - Production data at 50nA
    • Swing - Production data at 50nA
  • Thursday
    • Owl - Production data at 50nA
    • 7am Request Restricted Access, Ramp Down the magnets, Empty and warm up target
    • 7am Contact Eugene as soon as beam off


  • Please note that we have added two items to the list of tasks for each run.
    • (1) When you collect the gui snapshots for the logbook (scalar gui, FTC Asym plot, livetime, ROC rates, beamline stripcharts) include the DAQ gui AND make sure the snapshot is taken when you're running. We want to record the rate plots on the DAQ gui.
    • (2) Measure the trigger structure (trigger-time distribution) about every 30 minutes and at least once per run enter the results in the logbook. See below for instructions. This is needed to monitor the injector laser phase which created serious problems last week.
  • If the trigger-time distribution or region 1 DC occupancies get worse ( > 6.5%) call the RC. What we will likely do is reduce the beam and restart.
  • At some later time we need to do an empty target run. Current will be 150 nA for 50M triggers which should take 2-3 hours.

DAQ config: PROD66

Trigger file : rgb_inbending_v9_1.trg


Compare the monitoring histograms


Run database: when starting/stopping a run, enter (or check if already present) the requested current in the pop-up window and put RELEVANT COMMENTS (eg: "production run", "trigger test vXX, changed this and that" not just "run") -- please label junk runs if you get the chance. Please also keep a record of run numbers and their conditions in the shift summary. The information you enter in the dialogue box goes directly into the run database -- it's our primary source of run info and mistakes are hard to correct a posteriori.


Please run the script to look at trigger structure once per shift and check that you get a smooth distribution. Instructions are here: [1]

Keep an eye on CND channel S14L1R -- it's a bit temperamental. If it trips, switch HV off and on again for it and make an entry in the log book.


At the end of each run, follow the STANDARD DAQ RESTART SEQUENCE
This needs to be followed at the end of every run. Note: this might be different from the instructions coming up on RunControl.

  • "end run", "cancel", "reset"
  • if the run ended correctly:
    • "download", "prestart", "go"
  • if the run did not end correctly or if any ROCs had to be rebooted:
    • "configure", "download", "prestart", "go"
  • After each step, make sure it completed in the Run Control message window. If a ROC has crashed, find which one it is, issue a roc_reboot command ON JUST THAT ROC and try again. Contact the DAQ expert if there are any questions.


References and Standards:

(last update 1/14/2020- 23:20)

Nominal Beam Positions

  • 2H01, X: +1.0 mm, Y: -2.6 mm
  • 2C21, X: 0.0 mm, Y: 0.2 mm
  • 2C24, X: -0.3 mm, Y: -0.8 mm

FSD Thresholds

  • Upstream: 2000 Hz
  • Midstream: 2000 Hz
  • Downstream: 700000 Hz
  • BOM: 60000

Reference Harp Scans for Beam on Faraday Cup: 2C21 [2], 2C24 (tagger harp) [3], 2H01 [4]

Reference Harp Scans for Beam on Tagger dump: 2C21 [5], 2C24 (tagger harp) [6]

Reference Monitoring Histograms (40 nA, production trigger) [7]

Counter rates

  • Upstream counters integrated rates: 0-15 Hz (acceptable up to 100 Hz are acceptable) @50 nA.
  • Midstream counters: 10-20 Hz (acceptable up to 50 Hz) @50 nA.
  • Counting rates of ~ hundreds of Hz may indicate bad beam tune or bleed-through from other Halls.

Beamline vacuum: should be not higher than 5e-5.


General Instructions:

  • The main lights in the Hall (dome lights) and the Forward Carriage lights are being kept off because of light leaks affecting some of the detectors. If these lights are switched on during an access, they should be switched off when leaving the Hall. Note that the dome lights when switched off cannot be turned back on immediately because they require 10-15 min to cooldown.
  • Do not run more than 30 minutes above 30 nA with 5-pass beam without the beam blocker in front of Faraday cup . Put beam blocker in for long running at high currents for 5 pass operations.
  • Turn DC HV off only for beam tuning; if no beam is available or when beam is stable, keep them on even if you are not taking data.
  • In case of loss of communication with IOCBTARG , follow instructions at https://logbooks.jlab.org/entry/3502218
  • With any issue contact On-Call Experts or RC - do not spend more than 15-20 min trying to fix the problem. If the phone is not answered, try the "Page Experts" button on top of CLASCSS.
  • Check for and read any comments to log-book entries made during your shift!


Every Shift:

  • Follow run plan as outlined by RC
  • If any concern about beam stability, ask MCC if orbit locks are on (they should be).
  • Keep shift summary up to date in HBLOG. Record all that happens.
  • Document any beam condition change and send scaler GUIs to HBLOG
  • Fill out BTA hourly. Click "Load from EPICS" to automatically fill the left side. Run the script btaGet.py to print for you the correct BTA info for this hour -- edit the values on the BTA page if they are wrong!
  • Upload spectra from clas12mon at begin and end of shift and cross-check with reference spectra (make sure you select the SAME SECTOR as for the reference plots on tabs which have multiple sectors).
    • Reset clas12mon every ~2 hours and inspect spectra (some detectors have buttons at the bottom to toggle between the sectors -- please check all of them).
  • Fill and submit the shift checklist in the logbook
  • Run script to check smoothness of the trigger time structure: [8]
  • Monitor the SVT Slow Controls status, post plot of current stability in the HBSVT elog once per shift.


Every Run:

  • Check values at the start of every run and log screenshots of:
    • Main scaler GUI display
    • Trigger rate GUI
    • Beam strip charts
    • FTC scalers
  • At the start and end of every run, check that the data filled in the database run list is correct (especially fields which are filled in manually, like beam current and comments). This replaces the previously-used spreadsheet.
  • When checking the ECAL response, make sure to look at the histograms for each sector by using the sector buttons at the bottom of the clas12mon window - if adcecal* or/and adcpcal* ROC crashes, there will be no alarm and the histograms are the way to notice this issue.
  • Same holds for FTOF.


To access the Hall:

  • If you need to go down into Hall B alert Denny Insley (757-897-9060, cell/text: 757-810-9576) and the Run Coordinator (757-575-7540).
  • Check in with the shift personnel before entering the hall.


Notes / Troubleshooting :

If crate ADCBAND was rebooted: Contact BAND expert and make a note in the HBBAND logbook and in HBLOG.

FTOF HVs: The goal is to minimize the number of power cycles of the dividers.

    • OFF during: initial beam tuning to the Faraday Cup after CLAS12 has been off for a long shutdown, during a Moller run, harp scans, or if there is tuned/pulsed beam in the upstream beamline.
    • ON after an initial beam tune has been established and if there are only minor steering adjustments and “tweaks” being made.
    • If in doubt, call FTOF expert

FTT (mmft1) recovery:

    • power cycle FTT LV (FT->FTT->turn LV OFF, turn LV ON)
    • RunControl "reset"
    • roc_reboot mmft1

Torus and/or Solenoid Fast Dump

    1. Notify MCC to request beam OFF and to drop Hall B status to Power Permit
    2. Call Engineering on-call
    3. Make separate log entry with copies to HBTORUS and HBSOLENOID logbooks. In the "Notify" field add Ruben Fair, Probir Goshal, Dave Kashy and esr-users@jlab.org
    4. Notify Run Coordinator
    5. Turn off all detectors


Beam to the Faraday Cup: Fast Shut Down elements

  • Upstream, Midstream, Downstream, BOM, and Solenoid FSD elements should always be in the state UNMASKED
  • No changes to the FSD threshold should be made without RC or beamline expert approval


Turning MVT off: do not press "All HV OFF". Instead go to 'Restore settings' from the MVT overview screen:

    1. SafeMode.snp for beam tuning and Moeller runs
    2. MV_HV_FullField.snp for full solenoid field
    3. MV_HV_MidField.snp wgeb solenoid < 4T


CND CAMAC crate switch on / reboot:

If CAMAC crate (camac1) holding CND CFD boards is switched off for any reason, always reset the associated CND CFD thresholds by typing, ssh into clondaq3 and type:

$CODA/src/rol/Linux_x86_64/bin/cnd-cfd-thresh -w 0

If this command is failing and the crate is not responding, first reboot it as follows: roc_reboot camac1

and then repeat the threshold reset command above.


Solutions for common SVT issues: see [9]


RICH recovery procedures: [10]

To be followed in case of:

  1. DAQ crash: rich4 is not responding or
  2. RICH alarms (LV,missing tile, temperature, etc).

If it does not work or you are uncertain about what to do, contact the RICH expert on call. Please note that missing tiles typically occur due to lost communication. Keep in mind that the recovery procedure will kill DAQ. If DAQ is running for purpose other than data taking (for which the RICH acceptance is important) do not initiate the recovery procedure. The most critical parameter for the RICH is the temperature of the photosensors. If the temperature rises above limits, an interlock will automatically turn the RICH HV and LV off. If this happens, notify the expert on call and keep taking data without RICH.


Observed asymmetry in FTCal ADC Scalers

When running at low current (<10 nA), FTC asymmetries can be affected by hot channels. If large asymmetries are detected in those conditions, cross check with other detectors (BOM rates, DC occupancies) before taking further action.


CED display not showing events

Sometimes, CED screens are up but not active (events not showing at all). To solve this:

  1. Close the CED sceen
  2. ssh to clondaq4
  3. Once in the right machine, type ced, and wait for the windows to appear.
  4. Go to "File" -> "Connect to ET ring". Make sure to select clondaq6, as the online data is being streamed.
  5. Go to "Events" (same level as "File") and check "Auto Next-Event Every 2.0 sec" (if it is not selected).

You should see the events now, if all is working well.


Clas12design.png