Difference between revisions of "HYP Target Meeting 20231030"
Jump to navigation
Jump to search
Line 8: | Line 8: | ||
[[Media:HKS-target meeting gogami 20231030.pdf|HKS-target_meeting_gogami_20231030.pdf]]</font> | [[Media:HKS-target meeting gogami 20231030.pdf|HKS-target_meeting_gogami_20231030.pdf]]</font> | ||
==Target list (only solid targets for the next run)== | ==Target list (only solid targets for the next run)== | ||
− | |||
=== Approved=== | === Approved=== | ||
* E12-15-008: <sup>40</sup>Ca, <sup>48</sup>Ca (150 mg/cm<sup>2</sup>) | * E12-15-008: <sup>40</sup>Ca, <sup>48</sup>Ca (150 mg/cm<sup>2</sup>) | ||
Line 22: | Line 21: | ||
* LOI12-23-016: <sup>27</sup>Al (100 mg/cm<sup>2</sup>) | * LOI12-23-016: <sup>27</sup>Al (100 mg/cm<sup>2</sup>) | ||
* LOI12-23-011: there may need special needs. | * LOI12-23-011: there may need special needs. | ||
+ | ==Some comments== | ||
+ | * Solid targets are planned to be used for the next run. <br> But, the target system would be better to be compatible with gas targets ([https://researchmap.jp/gogami/published_papers/42604225/attachment_file.pdf E12-19-002]). | ||
+ | * ERR, for example, in Mar is possible for the (solid) target part. | ||
+ | * Requirements for the target (position accuracy etc.) need to be summarized. | ||
+ | * Let's keep using MS Sharepoint for sharing information and documents. | ||
Revision as of 16:18, 31 October 2023
Target Meeting (Hypernuclear experiment at JLab)
- 23:00-24:00 on Oct 29th, 2023 EDT (12:00-13:00 on Oct 30th, 2023 JST)
- Participants: David Meekins (JLab), Toshiyuki Gogami (Kyoto Univ.)
- via ZoomGov
Discussion
HKS-target_meeting_gogami_20231030.pdf
Target list (only solid targets for the next run)
Approved
- E12-15-008: 40Ca, 48Ca (150 mg/cm2)
- 40 is easy to obtain, but not for 48.
- Dave asked Oak Ridge National Lab. to purchase the Ca material.
→ no response yet.
→ Dave will contact the Lab.
- E12-20-013: 208Pb (100-150 mg/cm2)
- The thickness needs to be fixed for design.
- Cryogenic system would be needed for cooling.
- 20 μA would be OK to apply.
- Common calibration: 12C (150 mg/cm2), CH2 (500 mg/cm2), 27Al (150 mg/cm2)
Proposing next year
- LOI12-23-013: 6Li, 9Be, 11Be (100 mg/cm2)
- LOI12-23-016: 27Al (100 mg/cm2)
- LOI12-23-011: there may need special needs.
Some comments
- Solid targets are planned to be used for the next run.
But, the target system would be better to be compatible with gas targets (E12-19-002). - ERR, for example, in Mar is possible for the (solid) target part.
- Requirements for the target (position accuracy etc.) need to be summarized.
- Let's keep using MS Sharepoint for sharing information and documents.
Next Meeting
13:00 p.m.- on Nov 14, 2022 (EDT) at JLab.
https://indico.jlab.org/event/742/